การปรับปรุงสําคัญ

East China R32 references stayed at ¥63,500–64,500 per tonne

OilChem’s 25 November East China table kept R32 and refrigerant-grade R22 unchanged from the previous working day. A ¥65,500 factory figure on the same page is not in that table.

The 09:01 table lists refrigerant-grade R22 at ¥17,000 per tonne, R125 ใน ¥52,000–53,000, R134a ใน ¥63,500–65,000 และ R410A ใน ¥55,000–56,000. Every row’s change from the previous working day is zero. The note says these are point ex-works references, not daily averages. Mysteel’s 14:23 reprint matches the R32 and refrigerant-grade R22 ranges.

The page is marked as AI-generated. Its outlook also refers to a factory offer near ¥65,500 per tonne for China-market and export supply together. That figure is outside the table. Mysteel’s reprint puts feedstock-grade R22 at ¥12,000 per tonne, while the morning table puts it at ¥13,000–14,000. Confirm grade, packaging and delivery terms before using either number in a budget.

Tianjin commissions data-centre waste-heat heating

A 23 November notice says cooling-water heat from the national supercomputing centre now heats 160,000 m². The stated coal and CO₂ savings are the publisher’s estimate.

The Tianjin Economic-Technological Development Area said the Tianhe Digital Industrial Park project is in operation. Tianjin TEDA Energy Technology and Broad Air Conditioning implemented it. A magnetic-bearing heat pump lifts heat from the supercomputing centre’s cooling water. A storage tank and an electromagnetic boiler sit with it. The heated area covers eight park buildings and the supercomputing centre’s office, 160,000 m².

The notice says the tank is charged on off-peak electricity and the boiler is the backup for extreme cold. It estimates about 600 tonnes of standard coal and about 1,560 tonnes of CO₂ a year. Those figures are labelled as a calculation, not a completed year of metered heat. The same notice does not give supply and return temperatures, heat-pump capacity or measured electricity use.

New Zealand shows a pilot heat pump for 120°C steam

The University of Waikato described the pilot on 25 November and showed it in Hamilton on 26 November. The “three or four times” remark is not a measured COP for this unit.

The Ahuora Energy Centre, with Excel Refrigeration and Air Conditioning, built what the university calls New Zealand’s first pilot-scale heat pump that can make steam. It is designed for 120°C steam และ 85°C hot water, for dairy, meat, food and wood processing that uses low-pressure steam. The Energy Efficiency and Conservation Authority co-funded the project and the 26 November showing at The Pā.

Project lead Keegan Hall’s “three or four times the heat” sentence describes heat pumps in general. The university does not publish a measured COP, steam flow or operating hours for this pilot. Director Tim Walmsley said the next step is a larger installation, starting with an early adopter. One example given is warm wastewater used to make steam for milk sterilisation and hot water for cleaning. That is an illustration, not a reported plant result.

EXQUISHEAT reviews 28 food and beverage processes

At its 24–25 November meeting in Berlin, the project said temperature ranges from 11 companies broadly match the literature. Load profiles still decide whether a heat pump fits.

GEA Heating & Refrigeration hosted the project’s second general assembly. EXQUISHEAT said it has analysed 28 processes from 11 companies in six European countries. The preliminary findings say the temperature ranges generally match published literature, and that load profiles matter when judging a heat-pump integration. Average process handbooks are described as coming soon. They were not on the project site at this review.

A first look at 20 stakeholder interviews lists four recurring barriers: investment return, limited knowledge of the technology, difficulty of tying a heat pump into an existing plant, and scarce finance. Standardised guidance for four food and beverage applications is still being written. The meeting did not publish site measurements or a selected machine.

HEATEXPO puts industrial heat, cooling and waste heat on one floor

The Dortmund fair ran on 24–26 November, with about 275 exhibitors. Hall 7 covered large heat pumps, industrial waste heat and process heat. The fair is not a performance test.

tab.de reported the opening on 24 November: about 275 exhibitors from 16 countries. New Hall 7 covers heat and cooling generation and industrial uses, including large heat pumps, combined heat and power, geothermal energy, plant engineering and industrial waste-heat use. The published agenda also includes waste heat from data centres and process-heat storage. VDMA Power Systems’ Dennis Rendschmidt said industrial process heat cannot be decarbonised by one technology, because temperatures and operating needs differ.

The German Heat Pump Association had announced a session for 25 November, 15:15–16:15, on the Blue Stage in Hall 4, about taking large heat pumps from concept to order. That announcement is dated 22 October. tab.de confirms the fair opened; it does not report measured performance from any machine on the floor. Opening hours announced by the association were 10:00–17:00 on 24 and 25 November, and 10:00–16:00 on 26 November.

A refinery review sets an order for low-grade waste heat

Hydrocarbon Processing on 24 November says to quantify streams and check direct recovery before ORC, heat pumps or absorption cooling. Feasibility studies are not operating results.

The review covers refineries, petrochemical plants, LNG and gas processing. Its order is: measure heat sources and sinks from plant data; use pinch analysis and the heat-exchanger network so recoverable heat is not turned into lower-value power while a heating need remains; look at steam and condensate recovery; then choose among ORC, heat pumps, vapour recompression, absorption cooling or desalination according to the site’s utility balance. The authors say ORC is the most widely demonstrated heat-to-power route for steady streams above about 70–90°C, and that this is not a rule for every plant.

The article separates field examples, feasibility studies, simulations and conceptual screens. It cites a Sinopec Guangzhou case in which steam-condensate heat drove a lithium-bromide refrigeration unit for process cooling. Reported paybacks and megawatt figures in the review stay inside the prices, running hours and capital costs of each source study. They are not this week’s operating results, and they do not transfer to another site.

วันที่

ใกล้จะมา

Standards check on 29 November. China’s open standards portal still lists GB/T 18837-2026 and GB/T 27941-2026 as in force, with an implementation date of 1 November. The Ministry of Ecology and Environment list is still headed by the 16 October notice on the 2027 allocation plan. No newly issued standard was added. The EU climate-action F-gas documentation page still shows 11 November as the latest publication date for the listed implementing regulations. The Japan Standards Association’s November index does not itself name individual refrigeration or heat-pump standards. No new United Kingdom text was confirmed this week.

  • 23 November: Tianjin announces that the data-centre waste-heat heating project is in operation. A draft for comment opens on part 4 of the refrigeration-system and heat-pump safety and environmental requirements, covering operation, maintenance, repair and recovery.
  • 24–26 November: HEATEXPO runs in Dortmund. EXQUISHEAT meets in Berlin on 24–25 November. Hydrocarbon Processing publishes the low-grade waste-heat review on 24 November.
  • 25–26 November: The University of Waikato describes the pilot steam heat pump and shows it in Hamilton. GEOFLEXheat’s webinar was on the 25 November agenda; no measured results were found afterwards. The German Heat Pump Association’s large-heat-pump session was listed for 25 November.
  • 27 November: A second draft for comment opens, on technical requirements for renewing multi-split air-conditioning (heat pump) systems. The notice does not assign a published standard number.
  • 1 เดือนธันวาคม: โฟร์มและรางวัลของ EHPA แปป๊ปป้อนความร้อน, บรูเซลส์
  • 2 December, 15:00–16:30 CET: เว็บไซน์ IEA HPT Project 68 เกี่ยวกับปั๊มความร้อนอุณหภูมิสูงในการแห้งอาหาร
  • 7–11 December: การประชุมคณะกรรมการบริหารกองทุนหลายฝั่ง 99 มีกําหนดไว้ในโอนเตรเลีย
แหล่งข่าว

แหล่งข่าว