Pembaruan utama

  1. China 1 Jul ODS cluster di minggu kedua: HCFC -141 b semprot, busa XPS dan larangan pelarut HCFC di bawah inspeksi aktif; FAS 2026 / 550 label proyektor di minggu kedua; tonggak berikutnya 1 Agustus label pemanas air surya rumah tangga; MEE 2027 ODS / HFC quota draft masih dalam komentar
  2. LG 7/8 industrial HTHP at Ajin P&P: ~1,000 RT system, 108°C outlet (max 118°C), R-1233zd (GWP=1), oil-free magnetic bearing; MOTIE carbon-neutrality R&D consortium since 2023
  3. Pekan produk R290 Eropa 7/8 - 10: Haier monoblok komersial 26 - 40 kW (kaskas hingga 320 kW, 80 °C DHW); Swegon Epsilon Zero 14 - 45 kW (9 Jul); Daikin Altherma 4 menambahkan 4 / 6 / 7 kW (10 Jul)
  4. Mitsubishi Electric UK white paper 7/10: Unlocking High Temperature Heat Pump Adoption—calls for regulatory reform and spark-gap action; Ecodan R290 up to 75°C flow retains existing radiators
  5. EPA Technology Transitions akhir aturan efektif 27 Jul—~ 15 hari dari briefing ini; minggu -27 HARDI / ACCA / PHCC jas dan Mahkamah Agung AIM Act afirmasi memberikan latar belakang
Kebijakan

Kebijakan & Regulasi

  • Cluster peraturan 1 Jul ODS China memasuki minggu penegakan kedua. Departemen ekologi lokal melanjutkan inspeksi ruang dingin, logistik dan situs isolasi industri di mana busa semprot poliuretan HCFC -141 b poliurethane sekarang dilarang di bawah Pengumuman MEE 2025 Tidak. 28, di samping larangan busa XPS HCFC (Pengumuman No. 31) dan HCFC pembatasan pelarut dalam elektronik, instrumen dan mesin. Umpan balik industri minggu ini menunjukkan percepatan substitusi terhadap HFO dan agen penyemburan hidrokarbon dan dokumentasi pemulihan yang lebih ketat karena pengiriman proyek puncak musim panas berlanjut. Kap transfer lintas kategori HFC -245 fa naik menjadi 50% dalam minggu -24 MEE 2027 kuota draft tetap menjadi tuas kuota utama yang terkait dengan transisi busa ini; draft masih dalam komentar publik karena perusahaan menyiapkan pengajuan kuota 2027 karena 31 Oct 2026.
  • On 10 Jul Mitsubishi Electric published Unlocking High Temperature Heat Pump Adoption, a UK white paper calling on policymakers to revise rules that restrict high-temperature heat pump deployment and to address the electricity–gas price gap—the “spark gap”—that continues to suppress adoption despite improving technology. The paper notes the UK’s 450,000 heat-pump-per-year target by 2030 and that buildings account for roughly 21% of national greenhouse gas emissions, with four in five homes expected to exist in 2050 already built today. Pilot work with housing association Sovereign Network Group found that Mitsubishi’s Ecodan R290 heat pump delivering flow temperatures up to 75°C could retain existing radiators and microbore pipework, cutting installation time by up to 40%. The message parallels—but does not replace—the EU F-Gas 2027 GWP<150 placement ban that is driving R290 product launches across the continent this month.
  • Aturan akhir peninjauan ulang Transisi Teknologi EPA berlaku 27 Jul 2026—approximately 15 days from this briefing. Following the Supreme Court’s cert denial in RMS of Georgia v. EPA (week 27), contractors may continue installing pre-2025 R-410A residential and light-commercial inventory until depleted, a change welcomed by distributors. HARDI, ACCA, PHCC, AHRI and the Alliance for Responsible Atmospheric Policy continue separate DC Circuit challenges to the rule’s temporary GWP relaxation for supermarket, retail food and cold-storage commercial refrigeration to 1,400 from 2027 through 2032. Multinational OEMs must therefore plan for three parallel tracks: shrinking AIM Act HFC supply, contested US end-use deadlines, and tightening EU/UK low-GWP placement rules.
Pasar

Pasar &amp; Industri

  • LG Electronics marked a milestone in industrial heat pumps on 8 Jul, completing commercial operation of a ~1,000 refrigeration-ton (RT) high-temperature system at Ajin P&P’s paper mill in Daegu—the first commercial deployment of a unit developed under South Korea’s Ministry of Trade, Industry and Energy carbon-neutrality R&D programme involving 15 industry, academic and research partners since 2023. The system delivers outlet water at 108°C (maximum 118°C) for paper-drying and other high-temperature process heat, with up to 1,040 RT cooling capacity on the refrigeration side. LG applies proprietary oil-free magnetic bearing technology and R-1233zd refrigerant (GWP=1), replacing fossil-fuel combustion with electricity and waste-heat recovery. The case extends LG’s industrial portfolio beyond the COEX water-source heat pump (2024) and Ørsted district-heating supply (2025), and follows the company’s selection as top bidder for Jeju’s 2026 residential heat-pump distribution project—positioning LG across residential, commercial and industrial segments as Annex 68-style high-temperature applications move from pilot to site deployment.
  • Europe’s R290 launch wave intensified 8–10 Jul after Systemair’s Geniox HP DFN and LG Therma V monobloc releases (week 27). Haier introduced a commercial R290 air-to-water monobloc range in 26–40 kW classes, cascadeable to 320 kW for offices, hotels and small commercial buildings. Swegon launched Epsilon Zero on 9 Jul—14–45 kW R290 units for light commercial and multi-family housing with leaving water up to 75°C and integrated hydraulics for boiler-replacement retrofits. Daikin extended its Altherma 4 EPSKS R290 line on 10 Jul with 4, 6 and 7 kW units for mid- to highly insulated homes, filling the capacity gap below existing models. Together the releases trace a clear market gradient—residential monobloc (Daikin, LG) through light commercial (Swegon, Haier) to packaged AHU integration (Systemair, IV Produkt)—ahead of the EU’s 1 Jan 2027 GWP<150 placement ban.
Standar

Standar &amp; Kepatuhan

  • FAS 2026 / 550 label energi proyektor berada di minggu penegakan kedua mereka; tonggak katalog berikutnya adalah 1 Agustus 2026 untuk sistem pemanas air tenaga surya - sekitar 20 hari dari briefing ini. Perusahaan harus terus mempertahankan katalog label ganda (FAS 2025 / 45 untuk unit pompa panas dan chiller vs 2026 / 550 untuk peralatan, pencahayaan, proyektor dan segera pemanas air tenaga surya) dengan keterlacakan SKU -level dalam e-commerce dan dokumentasi tender. Produk yang diproduksi sebelum setiap tanggal efektif dapat menggunakan label lama hingga dua tahun di bawah aturan transisi saham. Lihat referensi cepat standar panas-pompa situs ini untuk jadwal label energi China.
  • EU F-Gas Regulation (EU) 2024/573 placement deadlines remain roughly six months away: from 1 Jan 2027, monoblock heat pumps and air-conditioning units ≤12 kW placed on the EU market must use refrigerants with GWP below 150. IV Produkt’s next-generation ThermoCooler HP for the Envistar Flex AHU range became available to order in the UK from 1 Jul, offering R290 (GWP 0.02) or R454C (GWP 146) via the Multiref dual-refrigerant concept—giving consultants a compliance path for self-contained equipment up to 50 kW before the 2027 threshold. Both versions include calibration-free leak detectors; the R290 variant adds IV Produkt’s patent-pending Evacuation Dilution Function. UK policy debate this week (Mitsubishi white paper) adds a domestic layer beyond EU F-Gas—high-temperature R290 products must satisfy both refrigerant placement rules and national installation standards.
Teknologi

Teknologi &amp; Demonstrasi

  • LG’s Ajin P&P system represents a step change in industrial heat-pump temperature lift. Conventional industrial units typically deliver ~90°C outlet water; LG’s design reaches 108°C with a 118°C maximum, sufficient for paper drying, food sterilisation and chemical processes previously dependent on fossil boilers. The oil-free magnetic bearing compressor eliminates lubricant maintenance and reduces parasitic losses; R-1233zd (GWP=1) keeps direct emissions negligible under AIM Act and EU F-Gas frameworks. With up to 1,040 RT cooling capacity, the unit can serve combined heating-and-cooling industrial loads—recovering waste heat rather than venting it—aligning with IEA HPT Annex 68’s focus on sector integration and high-temperature process decarbonisation.
  • This week’s R290 launches emphasise commercial scalability and retrofit compatibility. Haier’s monobloc range claims SCOP up to 4.91, leaving water to 80°C, sound levels from ~47 dB(A) and A+++ seasonal efficiency, with leak detection, refrigerant separation and sealed electrical enclosures; up to eight units cascade to 320 kW. Swegon’s Epsilon Zero targets boiler replacement with 75°C leaving water, hermetic scroll compressors, integrated hydraulics and DHW control in 14–45 kW reversible and heating-only versions. Daikin’s Altherma 4 extension adds 4–7 kW R290 monoblocs for smaller, well-insulated homes—completing a product ladder that mirrors the EU’s tiered GWP compliance timeline from residential splits through light commercial to integrated AHU solutions.
Tanggal

Datang

  • Completed this week: LG Ajin P&P industrial heat pump commercial operation (8 Jul); Haier commercial R290 monobloc launch (8 Jul); Swegon Epsilon Zero R290 range (9 Jul); Daikin Altherma 4 R290 extension (10 Jul); Mitsubishi Electric UK high-temperature heat pump white paper (10 Jul); ATMO America follow-up coverage on Lync by Watts CO₂ DHW electrification (6 Jul).
  • Ke depan: Aturan akhir Transisi Teknologi EPA efektif 27 Jul 2026; FAS 2026 / 550 label pemanas air tenaga surya rumah tangga dari 1 Agustus 2026; Konferensi Perlindungan Energi dan Lingkungan Berkelanjutan 2026, Roma, 20 – 23 Jul 2026; MEE 2027 ODS / HFC kuota draft (minggu 24) dalam komentar publik — Kuota 2027 dan pengajuan transfer awal jatuh tempo 31 Oktober 2026; EU F-Gas GWP < 150 larangan penempatan 1 Jan 2027; harmonisasi sertifikasi penangan F-gas 11 Mar 2027; Chillventa 2026 Nuremberg 13 - 15 Oct 2026.