Aggiornamenti chiave

  1. Cina 1 Jul Cluster ODS nella terza settimana: divieto di spray HCFC-141b, schiuma XPS e solventi HCFC sotto continua ispezione; FAS 2026/550 prossimo traguardo 1 Aug household solar water heating labels (~13 days); MEE 2027 ODS/HFC quota draft still in comment—filings due 31 Oct 2026
  2. Daikin Comfort Technologies North America launches NEXIO Max inverter rooftop heat pump on R-32: 7.5–10 ton, IEER 21–22, cold-climate heating to -25°C ambient; matches common curb footprints for retrofit
  3. AHRI May 2026 shipments (reported 14 Jul): central AC + air-source heat pumps 919,685 units, +6.7% YoY; heat pumps +2.3%; YTD combined shipments still -1.2%
  4. France Rappel Conso recall of Qlima WDH R290 all-in-one monoblocs (PVG): install height below 1.8 m risks flammable atmosphere on leak (~290 g charge)—installation compliance counterpoint to week-28 European R290 launch wave
  5. La normativa finale dell'EPA è in vigore 27 Jul~8 giorni da questa briefing; settimana-27/28 sfondo di installazioni di inventario e sfide del circuito DC continua
Politica

Politica e regolamentazione

  • China’s 1 Jul ODS regulatory cluster entered its third enforcement week. Ecology departments continue site checks on cold-room, logistics and industrial insulation projects where HCFC-141b polyurethane spray foam, XPS foam HCFC blowing agents and selected HCFC solvents remain prohibited under the 2025 MEE announcements detailed in weeks 27–28. Peak-summer project delivery keeps substitution toward HFO and hydrocarbon blowing agents and recovery documentation under pressure. The MEE 2027 ODS/HFC quota draft (week 24)—including the raised HFC-245fa cross-category transfer cap—remains in public comment; 2027 quota and initial transfer filings are due 31 Oct 2026.
  • European A3 installation discipline moved from product launches to enforcement headlines. France’s Rappel Conso lists a recall of Qlima WDH-series all-in-one R290 monobloc heat pumps (PVG Group, Oss)—models including WDH 224/229/235/429/435 PTC variants sold through DIY retail over roughly five years. Official guidance warns that units installed below 1.8 m can create a flammable atmosphere if R290 (~290 g) leaks. PVG is inspecting installations and applying corrective measures. The episode underscores that EU F-Gas pressure toward GWP<150 monoblocs by 1 Jan 2027 È inseparabile dai limiti di carica, dall'altezza di montaggio e dalla competenza di installazione non solo dalla scelta del refrigerante.
  • La nuova regola finale della transizione tecnologica dell'EPA entra in vigore 27 Jul 2026—approximately eight days from this briefing. As outlined in weeks 27–28, contractors may continue installing pre-2025 R-410A residential and light-commercial inventory until depleted, while HARDI, ACCA, PHCC, AHRI and allied groups pursue DC Circuit challenges to temporary GWP relaxation for certain commercial refrigeration end uses. Multinational OEMs remain on three tracks: AIM Act supply contraction, contested US end-use dates, and tightening EU/UK low-GWP placement rules.
Mercati

Mercato e industria

  • Daikin Comfort Technologies North America launched the NEXIO Max packaged rooftop heat pump (coverage 13–17 Jul), targeting light-commercial electrification and curb-compatible retrofits. The R-32 inverter unit is offered in 7.5, 8.5 and 10 ton cooling classes, with IEER 21.0–22.0 and EER 12.1–12.4; heating COP reaches about 3.85 at 8.3°C, and the design claims operation to -25°C ambient with ~85% rated heating capacity at -10°C. AHRI’s May 2026 shipment release (14 Jul) shows central AC and air-source heat pumps at 919,685 units (+6.7% YoY)—AC +10.2%, heat pumps +2.3%—while year-to-date combined shipments remain -1.2%, with heat pumps still slightly ahead YTD. The pairing reads as a strong replacement/cooling month alongside a steadier heat-pump trajectory ahead of US low-GWP and efficiency transitions.
  • On the wholesale and large-cooling side, Beijer Ref (17 Jul) reported a record Q2 2026: net sales SEK 10,785m (~€976m, +6%) and EBITA SEK 1,301m (~€118m). Organic growth was only 1% against tough Cool4U comparables, but 5% ex-Eastern Europe, led by OEM units SCM Frigo and Fenagy. Separately, Mitsubishi Heavy Industries shipped a 10 MW centrifugal chiller test unit to the US (Port of Brunswick, Georgia) for AI data-centre cooling trials, advancing its Modular Chiller Plant concept aligned with NVIDIA DSX liquid-cooled architectures and closed-loop free-cooling for PUE and water-use concerns—commercial availability targeted after UL and related certification.
Norme

Norme e conformità

  • La prossima pietra miliare del catalogo FAS 2026/550 è 1 Aug 2026 for household solar water heating system energy labels—about 13 days from this briefing—while projector labels remain in force from 1 Jul. Firms must keep dual catalogues (FAS 2025/45 for heat-pump and chiller units vs 2026/550 for appliances, lighting, projectors and soon solar water heaters) with SKU-level traceability. Looking further, GB/T 18837-2026 for multi-split air-conditioning (heat pump) units takes effect 1 Nov 2026, che sostituisce l'edizione 2015 pertinente per la documentazione dei prodotti VRF prima degli audit di autunno presso le fabbriche. Vedi questo sito Norme di pompa di calore riferimento rapido per il programma di etichette energetiche cinesi.
  • Il richiamo di Qlima rafforza le pratiche di sicurezza dell'UE nei confronti dei refrigeranti A3: carica (~ 290 g), altezza minima di installazione (1.8 m) e ispezione post vendita, in linea con i requisiti di stile EN/IEC 60335-2-40, poiché il gas F (EU) 2024/573 spinge i monoblocchi ≤12 kW verso GWP<150 da 1 Jan 2027Ora ci sono circa cinque mesi e mezzo. La capacità del canale si sta ampliando anche: Parts Town UK ha annunciato la formazione F-gas Category 1 (FCAT1 / Course 2079-11) presso la sua struttura di Cannock (16 Jul), un segnale pratico che la certificazione dell'installazione rimane un collo di bottiglia come idrocarburi e altre scale di attrezzature a basso livello GWP.
Tecnologia

Tecnologia e dimostrazioni

  • NEXIO Max packages cold-climate rooftop electrification in a retrofit-friendly envelope: a single inverter scroll compressor, dual variable-speed condenser fans, direct-drive indoor blower (300–1,600 rpm), factory R-32 charge of 335 oz (9.5 kg), and optional multi-zone VAV plus hot-gas reheat. Native BACnet and Daikin’s HERO cloud monitoring target light-commercial controls stacks. Matching common rooftop footprints without curb adapters reduces downtime—the practical bottleneck for packaged heat-pump replacement in North American strip retail and small offices, distinct from Europe’s week-28 R290 monobloc wave but aligned with the same electrification thesis.
  • Industrial HTHP narratives continued with DTI’s Project 68 update (Natural Refrigerants coverage 14 Jul, based on Vahterus Heat Pump Forum June 16–17). Across 40+ supplier projects in 14 countries, Andersen reports standardization around outlet temperatures up to 130°C (often 300–1,200 kW skids), custom modular systems toward 160–200°C, and steam-cycle demos beyond 160°C up to ~300°C. Natural refrigerants (CO₂, steam, hydrocarbons, ammonia–water) represent about 75% of the reviewed portfolio—“for every HFO HTHP there is a natural alternative.” Food & beverage (~33%), materials drying (~19%) and pulp & paper (~16%) dominate applications. The ladder complements week-28’s LG Ajin P&P 108°C commercial case: trust, operating hours and standardized offers—not thermodynamics alone—now gate wider industrial uptake.
Data di applicazione

Arrivo

  • Completed this week: Daikin NEXIO Max R-32 rooftop heat pump launch (NA, coverage 13–17 Jul); AHRI May 2026 shipment release (14 Jul); DTI/Project 68 HTHP standardization coverage (14 Jul); Parts Town UK F-gas Category 1 training announcement (16 Jul); Beijer Ref record Q2 results (17 Jul); MHI 10 MW centrifugal chiller shipment for US data-centre tests (17 Jul); continued media follow-up on France Qlima WDH R290 monobloc recall.
  • In futuro: conferenza SEEP 2026 sull'energia sostenibile e sulla protezione dell'ambiente, Roma, 20–23 Jul 2026; EPA Tecnologia Transizioni regola finale efficace 27 Jul 2026; etichette per il riscaldamento dell'acqua solare per uso domestico FAS 2026/550 1 Aug 2026; progetto di quota MEE 2027 ODS/HFC in commento pubblico2027 quota e presentazioni iniziali di trasferimento dovute 31 Oct 2026; standard multi-split GB/T 18837-2026 efficace 1 Nov 2026; Chillventa 2026 Norimberga 13–15 Oct 2026; divieto di immissione di gas F-GWP<150 dell'UE 1 Jan 2027; armonizzazione della certificazione dei gestori di gas F 11 Mar 2027.