Ana güncellemeler

  1. Çin 1 Jul ODS kümesi üçüncü hafta: HCFC-141b spreyi, XPS köpüğü ve HCFC çözücü yasaklamaları devamlı denetim altında; FAS 2026/550 bir sonraki ana nokta 1 Aug Evlerdeki güneş suyu ısıtma etiketleri (~ 13 günleri); MEE 2027 ODS/HFC kvota taslakı henüz yorum yapılmıyor 31 Oct 2026
  2. Daikin Comfort Technologies North America launches NEXIO Max inverter rooftop heat pump on R-32: 7.5–10 ton, IEER 21–22, cold-climate heating to -25°C ambient; matches common curb footprints for retrofit
  3. AHRI May 2026 shipments (reported 14 Jul): central AC + air-source heat pumps 919,685 units, +6.7% YoY; heat pumps +2.3%; YTD combined shipments still -1.2%
  4. France Rappel Conso recall of Qlima WDH R290 all-in-one monoblocs (PVG): install height below 1.8 m risks flammable atmosphere on leak (~290 g charge)—installation compliance counterpoint to week-28 European R290 launch wave
  5. EPA Teknoloji Değişiklikleri son kural etkin 27 JulBu brifingden sonraki günlerin 8'i; hafta -27/28'in envanter yüklemeleri ve DC Çeviri zorlukları devam ediyor
Politikası

Politika ve düzenleme

  • China’s 1 Jul ODS regulatory cluster entered its third enforcement week. Ecology departments continue site checks on cold-room, logistics and industrial insulation projects where HCFC-141b polyurethane spray foam, XPS foam HCFC blowing agents and selected HCFC solvents remain prohibited under the 2025 MEE announcements detailed in weeks 27–28. Peak-summer project delivery keeps substitution toward HFO and hydrocarbon blowing agents and recovery documentation under pressure. The MEE 2027 ODS/HFC quota draft (week 24)—including the raised HFC-245fa cross-category transfer cap—remains in public comment; 2027 quota and initial transfer filings are due 31 Oct 2026.
  • Avrupa A3 kurulum disiplini ürün başlatmalarından uygulama başlıklarına geçti. Fransa'nın Rappel Conso, yaklaşık beş yıl boyunca DIY perakende aracılığıyla satılan WDH 224/229/235/429/435 PTC çeşitleri de dahil olmak üzere Qlima WDH serisi tüm bir R290 monob Resmi rehberlik, 1.8 m'nin altında kurulan birimlerin R290 (~290 g) sızdırılması durumunda yanıcı bir atmosfer oluşturabileceğini uyarır. PVG tesisleri denetliyor ve düzeltme önlemleri uyguluyor. Bölüm, AB F-Gaz basıncının GWP<150'ye karşı monobloklar oluşturduğunu 1 Jan 2027 Üretim sınırları, monte edici yüksekliği ve kurulum yeteneğinden ayrılmaz.
  • EPA Teknoloji Değişiklikleri Tekrar Düşünme Son Kuralı Başlıyor 27 Jul 2026—approximately eight days from this briefing. As outlined in weeks 27–28, contractors may continue installing pre-2025 R-410A residential and light-commercial inventory until depleted, while HARDI, ACCA, PHCC, AHRI and allied groups pursue DC Circuit challenges to temporary GWP relaxation for certain commercial refrigeration end uses. Multinational OEMs remain on three tracks: AIM Act supply contraction, contested US end-use dates, and tightening EU/UK low-GWP placement rules.
Pazarlar

Piyasa ve Sanayi

  • Daikin Comfort Technologies North America launched the NEXIO Max packaged rooftop heat pump (coverage 13–17 Jul), targeting light-commercial electrification and curb-compatible retrofits. The R-32 inverter unit is offered in 7.5, 8.5 and 10 ton cooling classes, with IEER 21.0–22.0 and EER 12.1–12.4; heating COP reaches about 3.85 at 8.3°C, and the design claims operation to -25°C ambient with ~85% rated heating capacity at -10°C. AHRI’s May 2026 shipment release (14 Jul) shows central AC and air-source heat pumps at 919,685 units (+6.7% YoY)—AC +10.2%, heat pumps +2.3%—while year-to-date combined shipments remain -1.2%, with heat pumps still slightly ahead YTD. The pairing reads as a strong replacement/cooling month alongside a steadier heat-pump trajectory ahead of US low-GWP and efficiency transitions.
  • On the wholesale and large-cooling side, Beijer Ref (17 Jul) reported a record Q2 2026: net sales SEK 10,785m (~€976m, +6%) and EBITA SEK 1,301m (~€118m). Organic growth was only 1% against tough Cool4U comparables, but 5% ex-Eastern Europe, led by OEM units SCM Frigo and Fenagy. Separately, Mitsubishi Heavy Industries shipped a 10 MW centrifugal chiller test unit to the US (Port of Brunswick, Georgia) for AI data-centre cooling trials, advancing its Modular Chiller Plant concept aligned with NVIDIA DSX liquid-cooled architectures and closed-loop free-cooling for PUE and water-use concerns—commercial availability targeted after UL and related certification.
Standartlar

Standartlar ve Uyum

  • FAS 2026/550'nin bir sonraki kataloğu önemli bir adımdır. 1 Aug 2026 for household solar water heating system energy labels—about 13 days from this briefing—while projector labels remain in force from 1 Jul. Firms must keep dual catalogues (FAS 2025/45 for heat-pump and chiller units vs 2026/550 for appliances, lighting, projectors and soon solar water heaters) with SKU-level traceability. Looking further, GB/T 18837-2026 for multi-split air-conditioning (heat pump) units takes effect 1 Nov 2026, sonbahar fabrika denetimleri öncesinde VRF ürün belgesine ilişkin 2015 baskısının yerini alır. Bu sitenin ısı pompa standartları Çin enerji etiket programı için hızlı referans.
  • The Qlima recall sharpens EU safety practice around A3 refrigerants: charge (~290 g), minimum installation height (1.8 m) and post-sale inspection sit alongside EN/IEC 60335-2-40 style requirements as F-Gas (EU) 2024/573 pushes ≤12 kW monoblocs toward GWP<150 from 1 Jan 2027Yaklaşık beş buçuk ay sonra. Kanal kapasitesi de genişliyor: Parts Town UK, Cannock tesisinde F-gaz Kategori 1 (FCAT1 / Kurs 2079-11) eğitimini duyurdu (16 Jul), bu da kurulucu sertifikasyonunun hidrocarbon ve diğer düşük GWP ekipman ölçekleri olarak bir şişek kalmaya devam ettiğini gösterir.
Teknoloji

Teknoloji ve Gösteriler

  • NEXIO Max packages cold-climate rooftop electrification in a retrofit-friendly envelope: a single inverter scroll compressor, dual variable-speed condenser fans, direct-drive indoor blower (300–1,600 rpm), factory R-32 charge of 335 oz (9.5 kg), and optional multi-zone VAV plus hot-gas reheat. Native BACnet and Daikin’s HERO cloud monitoring target light-commercial controls stacks. Matching common rooftop footprints without curb adapters reduces downtime—the practical bottleneck for packaged heat-pump replacement in North American strip retail and small offices, distinct from Europe’s week-28 R290 monobloc wave but aligned with the same electrification thesis.
  • Industrial HTHP narratives continued with DTI’s Project 68 update (Natural Refrigerants coverage 14 Jul, based on Vahterus Heat Pump Forum June 16–17). Across 40+ supplier projects in 14 countries, Andersen reports standardization around outlet temperatures up to 130°C (often 300–1,200 kW skids), custom modular systems toward 160–200°C, and steam-cycle demos beyond 160°C up to ~300°C. Natural refrigerants (CO₂, steam, hydrocarbons, ammonia–water) represent about 75% of the reviewed portfolio—“for every HFO HTHP there is a natural alternative.” Food & beverage (~33%), materials drying (~19%) and pulp & paper (~16%) dominate applications. The ladder complements week-28’s LG Ajin P&P 108°C commercial case: trust, operating hours and standardized offers—not thermodynamics alone—now gate wider industrial uptake.
Tarihler

Yaklaşıyor.

  • Completed this week: Daikin NEXIO Max R-32 rooftop heat pump launch (NA, coverage 13–17 Jul); AHRI May 2026 shipment release (14 Jul); DTI/Project 68 HTHP standardization coverage (14 Jul); Parts Town UK F-gas Category 1 training announcement (16 Jul); Beijer Ref record Q2 results (17 Jul); MHI 10 MW centrifugal chiller shipment for US data-centre tests (17 Jul); continued media follow-up on France Qlima WDH R290 monobloc recall.
  • Önceden: SEEP 2026 Sürdürülebilir Enerji ve Çevre Koruma Konferansı, Roma, 20–23 Jul 2026; EPA Teknoloji Değişiklikleri son kural etkin 27 Jul 2026FAS 2026/550 ev içi güneşsel su ısıtma etiketleri 1 Aug 2026MEE 2027 ODS/HFC kvota taslağı açık yorumlarda2027 kvota ve ilk transfer kayıtları 31 Oct 2026; GB/T 18837-2026 çok bölünmüş standart etkin 1 Nov 2026Chillventa 2026 Nuremberg 13–15 Oct 2026; AB F-Gas GWP<150 yerleştirme yasaklaması 1 Jan 2027F-gaz muamelesi sertifikasyonunun uyumlandırılması 11 Mar 2027.