주요 업데이트

동중국 냉매 가격은 꾸준히 유지

Market reports for 9, 10, 12 and 13 November put R32 at ¥63,500–64,500 per tonne and refrigerant-grade R22 at ¥17,000 per tonne.

재 인쇄 된 보고서는 또한 수출 및 공급 원료 등급 R22를 나열합니다. 톤당 12,000엔 각각. 톤당 다른 보고된 가격은 R125였습니다. ¥54,000–57,000, R134a ¥63,500–65,000, R410A ¥57,000–59,500R404A 및 R507A ¥53,000–54,000 each. Some individual articles were incomplete, and the hub excerpts reviewed did not include an 11 November East China report.

The 13 November morning note put the delivered tender price for hydrofluoric acid (HF) at 톤당 15,300~15,650엔 그리고 대략에 R125 가동 비율 40%. 가격표는 불완전했다. 주 45의 아침 보고는 공급 원료 급료 R22를에 두었습니다 톤당 13,000~14,000엔. 비슷한 출처와 견적 용어를 사용하여 가격 추세를 판단하십시오.

The 6–12 November review excerpt reported plans to produce 12.23 백만 home air conditioners in November, up 18.97% from October. Its fourth-quarter contract references, payable by acceptance bill, were 톤당 65,600엔 R32 및 톤당 60,500엔 for R410A. A separate 11 November review quoted domestic R134a at 톤당 65,000~70,000엔 그리고 2026년 생산 할당량을에 보고했습니다 222,785 톤 그리고 국내 사용 할당량 90,914 톤. 이러한 할당량 수치는 시장 검토에서 나온 것입니다.

공장 따옴표는 공급자에 의하여 변화합니다

On 13 November, Juhua quoted R22 at ¥24,000 per tonne and Meilan quoted ¥20,000. R32 factory quotes also varied.

The 13 November factory reports listed R32 at 톤당 65,500엔 주화에서, ¥64,500 Meilan에서, ¥63,500 Yonghe에서 그리고 ¥66,000 from Dongyang. Dongyue’s 12 November quote was 톤당 65,500엔. R22의 경우 Dongyue 인용 ¥24,000 on 12 November and Limin quoted ¥19,000 on 13 November.

The 13 November reports also listed R134a at 톤당 £63,500 Yonghe에서, ¥65,000 Juhua와 Meilan에서, ¥68,000 Sinocem Lantian 및 ¥70,000 동양에서. 일부 인용문은 부재 중이거나 재 인쇄물에서만 사용할 수 있습니다. 등급과 견적이 지역 시장 가격과 비교하거나 조달 비용을 추정하기 전에 전 작업, 배달 또는 세금 포함 여부를 확인하십시오.

EU, 특정 실내 모노블록 히트펌프에 대한 2027 면제 목록

The European Commission lists a one-year exemption for certain models. The regulation text was unavailable at review, so capacity, refrigerant and labelling conditions remain unverified.

위원회의 F-가스 목록은 구현 규정을 식별합니다. (EU) 2026/2486 실내에 설치된 특정 모노 블록 히트펌프에 대한 시장 배치 면제로. 그것은에 게시를 나열 11 November 2026 그리고 application from 1 January to 31 December 2027. 동일한 목록은 공작 기계 냉각기에 대한 별도의 면제를 기록합니다. (EU) 2026/2485 그리고 의학 냉각장치 (EU) 2026/2491, 각각 2030년과 2028년에 끝납니다.

주 45는 1 January 2027 의 제한 GWP 150 이하 특정 자급 자족 에어 컨디셔너 및 히트펌프를 위해 50 kW, 안전 예외. GWP는 지구 온난화 잠재력을 의미합니다. 2026/2486의 진입은 해당 제한을 일반적으로 해제하는 것으로 취급할 근거를 제공하지 않습니다. 규정 준수 결정을 내리기 전에 정확한 모델, 냉매 및 라벨링 요구 사항에 대한 법적 텍스트를 확인하십시오.

영국 보일러 업그레이드 계획, 나머지 예산 보고

영국 규제 기관인 Ofgem은 2026년 – 27년 동안 62.665만 파운드가 남아 있다고 보고했습니다. 이 수치는 이미 발급되었지만 아직 사용되지 않은 보류중인 응용 프로그램 및 바우처를 허용합니다.

Ofgem은 수치를 업데이트했습니다. 11 November, with data through 데이터 31 October. 그것은보고 175,160 바우처 신청, 113,079 바우처 발급, 101,742 구속 및 £728.3855 백만 계획이 시작된 이래로 지불 된 보조금. 나머지 예산은 바우처가 만료되거나 반환 될 때 변경 될 수 있습니다.

A 분리 5 November Ofgem이 발행 할 수있는 통지 £520 million 회계 연도의 바우처. 를 사용하여 £ 62.665 백만 Ofgem의 보고된 잔여 예산 및 £520 million 바우처 천장에 대한 그림. 프로젝트 예산에 보조금을 포함하기 전에 계획의 자격 규칙을 확인하십시오.

중국의 두 가지 업데이트 된 다중 분할 표준이 시행 중입니다.

China’s standards portal lists both GB/T 18837-2026 and GB/T 27941-2026 as in force from 1 November 2026.

GB/T 18837-2026 다중 분할 에어컨 및 히트펌프 장비를 커버하고 2015 년 에디션을 대체합니다. GB/T 27941-2026 디자인 및 설치를 커버하고 2011 년 판을 대체합니다. 둘 다에 게시되었습니다. 30 April 2026. 프로젝트를 검토할 때 제품 점검 및 설계 및 설치 표준에 장비 표준을 사용하십시오.

에서 At the 15 November 검토, 중국 생태 및 환경부는 날짜 2027 할당량 제도 통지를 나열 16 October. 2027 할당량을 할당하는 통지는 검토 된 목록에 없었습니다. 위의 R134a 수치는 시장 검토에서 나온 것입니다.

일본 표준 협회 일정 예정 JIS B 8630 그리고 JIS S 2076 for 20 October. 두 표준의 출판은이 검토에서 확인되지 않았습니다.

COP31 사이드 이벤트는 자발적인 냉각 로드맵을 지원합니다.

The 16 November ministerial communiqué supports a proposal for a voluntary roadmap, with consultation and testing planned for 2027. It is a statement from the side event. Any new project requirement needs an adopted decision or applicable rule.

유엔 기후 사무국은 Türkiye의 Antalya에서 COP31을 예정했습니다. 9–20 November 2026. The 15 November presidency letter expected technical talks to end on 17 November and a draft overarching decision to circulate. On 17 November, 보도는 초안이 유포되었다고보고했습니다. 그 문구와 모든 종결 결정은이 검토 당시 확인되지 않았습니다.

The 16 November Antalya Communiqué는 열 탄력성과 지속 가능한 냉각에 대한 자발적인 국가 주도 로드맵 작업을 지원합니다. 그것은 상담 및 테스트를 제안합니다. 2027 및 Presentation at COP32. 각국은 글로벌 냉각 서약에 서명했는지 여부에 관계없이 참여할 수 있습니다. 별도의 Antalya-to-Addis 선언은 여전히 협의 초안이었습니다. 커뮤니케는 새로운 냉매 할당량이나 히트펌프 성능 요구 사항을 설정하지 않습니다.

Cool Coalition의 이벤트 요약은 두 가지 COP31 대통령 목표를 인용합니다. 2035: a 25% 건물 부문 에너지 강도 및 전기 도달 감소 35% 최종 에너지 사용의 유엔 환경 계획 (UN Environment Programme)의 연설은 지속 가능한 냉각 시나리오에서 가능한 이점을 설명합니다. 연설과 커뮤니케 별관은 다른 수치를 사용하며,이 브리핑은이를 결합하지 않습니다. 장비 또는 냉매 결정에 대해 채택 된 규칙 및 표준을 사용하십시오.

날짜

다가오는

The East China bands on 9, 10, 12 and 13 Nov match the bands at the end of week 45. Meilan’s R22 is ¥20,000/t and Limin’s is ¥19,000/t, beside Juhua and Dongyue at ¥24,000/t. The Commission list prints a monoblock exemption that applies through 2027. Ofgem prints £62,665,000 remaining in year 5, and that line is not the £520 million ceiling. The full-text pages returned and say the two multi-split standards are in force. No 2027 quota issuance notice was on the ministry list. The JSA maintenance notice is no longer at the old address. COP31 in Antalya runs to 20 Nov. The 16 Nov cooling communiqué is not a COP decision. The cover text was not opened on 17 Nov.

  • 11 Nov 2026: the Commission F-gas list prints this publication date for Implementing Regulations (EU) 2026/2485, 2026/2486 and 2026/2491. Application of 2026/2486 starts on 1 Jan 2027 and ends on 31 Dec 2027. The regulation text was not returned.
  • 11 Nov 2026: Ofgem Boiler Upgrade Scheme statistics, last updated this day. The table runs to 31 Oct 2026. Year-5 remaining budget is £62,665,000 and includes vouchers not yet redeemed. The £520 million ceiling is not on this page.
  • 11 Nov 2026, 17:50: Longzhong 일일 리뷰. 2026 R134a 할당량 수치는 가격 섹션에 있습니다. 페이지가 스폿 테이블에서 차단됩니다.
  • 12 Nov 2026, 17:57: Longzhong weekly review for 6–12 Nov. The hub excerpt prints the fourth-quarter contract references and cuts off inside the R22 plant band. The oilchem body was not returned.
  • 13 Nov 2026, 08:27: Longzhong morning note. The November HF tender is in the price section. The price table cuts off inside the first row.
  • 15 Nov 2026: openstd and the information platform label GB/T 18837-2026 and GB/T 27941-2026 as in force. On 8 Nov the openstd addresses returned no text. The ozone page still has no 2027 issuance notice. The JSA PDF address now returns the October planned list. JIS B 8630 and JIS S 2076 were not confirmed as published.
  • 9–20 Nov 2026: COP 31, CMP 21 and CMA 8 in Antalya, from the UNFCCC note opened 17 Nov. The opening plenary is 10:00 on 9 Nov. The Leaders Summit is 11–12 Nov. No closing decision was opened.
  • 15 Nov 2026: COP31 presidency message. The subsidiary bodies have concluded. A first cover draft is intended for early the following week. Technical negotiations are expected to conclude on 17 Nov. No page opened on 17 Nov said they had concluded. No heat-pump standard or refrigerant quota is on that message.
  • 16 Nov 2026, 18:30–20:00: Third Annual Cooling Ministerial, ANFAS Expo Center. The communiqué welcomes a voluntary roadmap and a draft declaration, both aimed at COP32. It is not a COP decision.
  • 16 Nov 2026: UN News and the IETA daily report say a first cover draft was circulated. The draft was not opened. The CCAC page prints both 14 Nov and 16 Nov. It does not print a new HFC control schedule.
  • 20 Nov 2026: the end date printed on the UNFCCC note. No closing text was opened on 17 Nov.
  • 1 Dec 2026: not printed as an effective date on the Commission list that was read. 2026/2486 is printed as applicable from 1 Jan 2027.
  • 1 Jan 2027: 2026/2486 starts to apply, and ends on 31 Dec 2027. The GWP<150 limit for defined self-contained air conditioners and heat pumps up to 50 kW stays as written in week 45. China bans production of HCFC-22 multi-split air-conditioning (heat pump) units, from the MEE notice of 2 Sep 2026. Chapter 738’s dates stay as written in week 45. No new California notice was opened this week.
  • 1 Apr 2027: energy-saving materials return to 5% VAT, and heat batteries join that list. The British Industrial Competitiveness Scheme starts in April 2027. Those sentences stay as written in week 45. They were not re-opened.
  • 30 Apr 2027 and 31 Aug 2027: 2027 할당량이 발행된 후 두 개의 HFC 할당량 조정 창. 그들은 주 45에 기록 된대로 유지됩니다. 계획 PDF는 다시 열리지 않았습니다.
  • 1 Jul 2027: 가정용 전기에 대한 임시 0 % VAT 세율은이 날짜까지 실행됩니다. 가스 스탠딩 요금은 2027년 말 또는 그 후 가능한 한 빨리 목표로 합니다. 그 문장은 주 45에 기록 된대로 유지됩니다.
  • 9–15 Nov 2026 — European Union: the three implementing regulations were published on 11 Nov. None of the rows that were read starts to apply inside these seven days.
  • 오프닝 날짜 없음: 캐나다의 히트펌프 리베이트 포털은 여전히 42 주 기록에 오프닝 날짜가 없습니다. 이번 주에는 새로운 통지가 열리지 않았습니다.