Key updates

East China refrigerant prices held steady

Market reports for 9, 10, 12 and 13 November put R32 at ¥63,500–64,500 per tonne and refrigerant-grade R22 at ¥17,000 per tonne.

The reprinted reports also list export- and feedstock-grade R22 at ¥12,000 per tonne each. Other reported prices per tonne were R125 ¥54,000–57,000, R134a ¥63,500–65,000, R410A ¥57,000–59,500, and R404A and R507A ¥53,000–54,000 each. Some individual articles were incomplete, and the hub excerpts reviewed did not include an 11 November East China report.

The 13 November morning note put the delivered tender price for hydrofluoric acid (HF) at ¥15,300–15,650 per tonne and the R125 operating rate at about 40%. Its price table was incomplete. Week 45’s morning report put feedstock-grade R22 at ¥13,000–14,000 per tonne. Use comparable sources and quote terms to judge a price trend.

The 6–12 November review excerpt reported plans to produce 12.23 million home air conditioners in November, up 18.97% from October. Its fourth-quarter contract references, payable by acceptance bill, were ¥65,600 per tonne for R32 and ¥60,500 per tonne for R410A. A separate 11 November review quoted domestic R134a at ¥65,000–70,000 per tonne and reported the 2026 production quota at 222,785 tonnes and the domestic-use quota at 90,914 tonnes. These quota figures come from a market review.

Factory quotes vary by supplier

On 13 November, Juhua quoted R22 at ¥24,000 per tonne and Meilan quoted ¥20,000. R32 factory quotes also varied.

The 13 November factory reports listed R32 at ¥65,500 per tonne from Juhua, ¥64,500 from Meilan, ¥63,500 from Yonghe and ¥66,000 from Dongyang. Dongyue’s 12 November quote was ¥65,500 per tonne. For R22, Dongyue quoted ¥24,000 on 12 November and Limin quoted ¥19,000 on 13 November.

The 13 November reports also listed R134a at ¥63,500 per tonne from Yonghe, ¥65,000 from Juhua and Meilan, ¥68,000 from Sinochem Lantian and ¥70,000 from Dongyang. Some quotes were absent or available only in reprints. Check the grade and whether the quote is ex-works, delivered or tax-inclusive before comparing it with a regional market price or estimating procurement cost.

EU lists a 2027 exemption for certain indoor monoblock heat pumps

The European Commission lists a one-year exemption for certain models. The regulation text was unavailable at review, so capacity, refrigerant and labelling conditions remain unverified.

The Commission’s F-gas list identifies Implementing Regulation (EU) 2026/2486 as a market-placement exemption for certain monoblock heat pumps installed indoors. It lists publication on 11 November 2026 and application from 1 January to 31 December 2027. The same list records separate exemptions for machine-tool chillers (EU) 2026/2485 and medical chillers (EU) 2026/2491, ending in 2030 and 2028 respectively.

Week 45 recorded the 1 January 2027 limit of GWP below 150 for certain self-contained air conditioners and heat pumps up to 50 kW, with a safety exception. GWP means global warming potential. The entry for 2026/2486 provides no basis to treat that limit as generally lifted. Check the legal text for the exact model, refrigerant and labelling requirements before making a compliance decision.

UK boiler upgrade scheme reports its remaining budget

UK regulator Ofgem reported £62.665 million remaining for 2026–27. That figure allows for pending applications and vouchers already issued but not yet redeemed.

Ofgem updated the figures on 11 November, with data through 31 October. It reported 175,160 voucher applications, 113,079 vouchers issued, 101,742 redeemed and £728.3855 million in grants paid since the scheme began. The remaining budget can change when vouchers expire or are returned.

A separate 5 November notice allowed Ofgem to issue up to £520 million in vouchers for the financial year. Use the £62.665 million figure for Ofgem’s reported remaining budget and the £520 million figure for the voucher ceiling. Check the scheme’s eligibility rules before including the subsidy in a project budget.

China’s two updated multi-split standards are in force

China’s standards portal lists both GB/T 18837-2026 and GB/T 27941-2026 as in force from 1 November 2026.

GB/T 18837-2026 covers multi-split air-conditioning and heat-pump equipment and replaces the 2015 edition. GB/T 27941-2026 covers design and installation and replaces the 2011 edition. Both were published on 30 April 2026. Use the equipment standard for product checks and the design and installation standard when reviewing a project.

At the 15 November review, China’s Ministry of Ecology and Environment listed the 2027 quota scheme notice dated 16 October. A notice allocating the 2027 quotas was not on the list reviewed. The R134a figures above are from a market review.

The Japanese Standards Association calendar scheduled JIS B 8630 and JIS S 2076 for 20 October. Publication of the two standards remained unverified at this review.

COP31 side event supports a voluntary cooling roadmap

The 16 November ministerial communiqué supports a proposal for a voluntary roadmap, with consultation and testing planned for 2027. It is a statement from the side event. Any new project requirement needs an adopted decision or applicable rule.

The UN climate secretariat scheduled COP31 in Antalya, Türkiye, for 9–20 November 2026. The 15 November presidency letter expected technical talks to end on 17 November and a draft overarching decision to circulate. On 17 November, coverage reported that a draft had circulated. Its wording and any closing decision remained unverified at the time of this review.

The 16 November Antalya Communiqué supports work on a voluntary, country-led roadmap for heat resilience and sustainable cooling. It proposes consultation and testing in 2027 and presentation at COP32. Countries can take part regardless of whether they have signed the Global Cooling Pledge. The separate Antalya-to-Addis declaration was still a draft for consultation. The communiqué sets no new refrigerant quotas or heat-pump performance requirements.

The Cool Coalition’s event summary cites two COP31 presidency objectives for 2035: a 25% reduction in building-sector energy intensity and electricity reaching 35% of final energy use. The UN Environment Programme’s speech describes possible benefits under a sustainable cooling scenario. The speech and the communiqué annex use different figures, and this briefing does not combine them. Use adopted rules and standards for equipment or refrigerant decisions.

Dates

Coming up

The East China bands on 9, 10, 12 and 13 Nov match the bands at the end of week 45. Meilan’s R22 is ¥20,000/t and Limin’s is ¥19,000/t, beside Juhua and Dongyue at ¥24,000/t. The Commission list prints a monoblock exemption that applies through 2027. Ofgem prints £62,665,000 remaining in year 5, and that line is not the £520 million ceiling. The full-text pages returned and say the two multi-split standards are in force. No 2027 quota issuance notice was on the ministry list. The JSA maintenance notice is no longer at the old address. COP31 in Antalya runs to 20 Nov. The 16 Nov cooling communiqué is not a COP decision. The cover text was not opened on 17 Nov.

  • 11 Nov 2026: the Commission F-gas list prints this publication date for Implementing Regulations (EU) 2026/2485, 2026/2486 and 2026/2491. Application of 2026/2486 starts on 1 Jan 2027 and ends on 31 Dec 2027. The regulation text was not returned.
  • 11 Nov 2026: Ofgem Boiler Upgrade Scheme statistics, last updated this day. The table runs to 31 Oct 2026. Year-5 remaining budget is £62,665,000 and includes vouchers not yet redeemed. The £520 million ceiling is not on this page.
  • 11 Nov 2026, 17:50: Longzhong daily review. The 2026 R134a quota figures are in the price section. The page cuts off at the spot table.
  • 12 Nov 2026, 17:57: Longzhong weekly review for 6–12 Nov. The hub excerpt prints the fourth-quarter contract references and cuts off inside the R22 plant band. The oilchem body was not returned.
  • 13 Nov 2026, 08:27: Longzhong morning note. The November HF tender is in the price section. The price table cuts off inside the first row.
  • 15 Nov 2026: openstd and the information platform label GB/T 18837-2026 and GB/T 27941-2026 as in force. On 8 Nov the openstd addresses returned no text. The ozone page still has no 2027 issuance notice. The JSA PDF address now returns the October planned list. JIS B 8630 and JIS S 2076 were not confirmed as published.
  • 9–20 Nov 2026: COP 31, CMP 21 and CMA 8 in Antalya, from the UNFCCC note opened 17 Nov. The opening plenary is 10:00 on 9 Nov. The Leaders Summit is 11–12 Nov. No closing decision was opened.
  • 15 Nov 2026: COP31 presidency message. The subsidiary bodies have concluded. A first cover draft is intended for early the following week. Technical negotiations are expected to conclude on 17 Nov. No page opened on 17 Nov said they had concluded. No heat-pump standard or refrigerant quota is on that message.
  • 16 Nov 2026, 18:30–20:00: Third Annual Cooling Ministerial, ANFAS Expo Center. The communiqué welcomes a voluntary roadmap and a draft declaration, both aimed at COP32. It is not a COP decision.
  • 16 Nov 2026: UN News and the IETA daily report say a first cover draft was circulated. The draft was not opened. The CCAC page prints both 14 Nov and 16 Nov. It does not print a new HFC control schedule.
  • 20 Nov 2026: the end date printed on the UNFCCC note. No closing text was opened on 17 Nov.
  • 1 Dec 2026: not printed as an effective date on the Commission list that was read. 2026/2486 is printed as applicable from 1 Jan 2027.
  • 1 Jan 2027: 2026/2486 starts to apply, and ends on 31 Dec 2027. The GWP<150 limit for defined self-contained air conditioners and heat pumps up to 50 kW stays as written in week 45. China bans production of HCFC-22 multi-split air-conditioning (heat pump) units, from the MEE notice of 2 Sep 2026. Chapter 738’s dates stay as written in week 45. No new California notice was opened this week.
  • 1 Apr 2027: energy-saving materials return to 5% VAT, and heat batteries join that list. The British Industrial Competitiveness Scheme starts in April 2027. Those sentences stay as written in week 45. They were not re-opened.
  • 30 Apr 2027 and 31 Aug 2027: the two HFC quota-adjustment windows after the 2027 quotas are issued. They stay as written in week 45. The scheme PDF was not opened again.
  • 1 Jul 2027: the temporary 0% VAT rate on household electricity runs to this date. Gas standing charges are aimed for the end of 2027, or as soon as possible after that. Those sentences stay as written in week 45.
  • 9–15 Nov 2026 — European Union: the three implementing regulations were published on 11 Nov. None of the rows that were read starts to apply inside these seven days.
  • No opening date: Canada’s heat-pump rebate portal still has no opening date in the week 42 record. No new notice was opened this week.
Sources

Sources