本期要點
- 華東 R32 報價區間持穩 OilChem’s 17 and 20 November East China references put R32 at ¥63,500–64,500 per tonne and refrigerant-grade R22 at ¥17,000 per tonne.
- Reported R32 factory quotes ranged from ¥64,000 to ¥66,000 per tonne Selected factory quotes published on 18–19 November varied by supplier and by the terms of supply.
- 歐盟公佈部分商用熱泵洗衣設備的限期豁免 Regulation (EU) 2026/2520 was published on 16 November and applies from 1 January 2027. Eligibility depends on appliance type, rated heat-pump capacity and operating conditions.
- 英國確認下一財年鍋爐升級補助預算 In a written answer on 18 November, the UK government confirmed £400 million for 2027–28. September application counts alone cannot establish when the budget will be fully committed.
- 印度提出約 400 kW CO₂ 工藝供熱示範 A Multilateral Fund meeting paper dated 17 November describes a transcritical CO₂ water-to-water heat-pump pilot. The funding decision and site selection are pending.
- 聯合國環境規劃署公佈可持續製冷新支持 On 17 November, UNEP said countries and partners had announced more than US$20 million in new support for the Global Cooling Pledge, alongside work on a voluntary roadmap.
華東 R32 報價區間持穩
OilChem’s 17 and 20 November East China references put R32 at ¥63,500–64,500 per tonne and refrigerant-grade R22 at ¥17,000 per tonne.
At the same reported points, R125 was ¥52,000–53,000 per tonne, R410A ¥55,000–56,000, and R134a ¥63,500–65,000. The 17 November morning note showed its mainstream R125 and R410A references down ¥2,500 and ¥4,000 per tonne respectively from the preceding working-day observation.
The 17 November data come from the market note and the 20 November figures from Mysteel’s reprint. These are dated ex-works references. Compare quotes for the same grade, packaging and delivery terms before using them for a budget.
Reported R32 factory quotes ranged from ¥64,000 to ¥66,000 per tonne
Selected factory quotes published on 18–19 November varied by supplier and by the terms of supply.
Fluorine Online reported R32 at ¥64,000 per tonne from Yonghe and ¥65,500 from Sanmei on 18 November. On 19 November it reported ¥65,500 from Dongyue and ¥66,000 from Dongyang. Sanmei’s figure covered domestic and export offers. Dongyang was mainly supplying contract customers.
The 18 November Quzhou Juhua report lists R22 at ¥17,000 per tonne and says actual prices are negotiated order by order, with small cylinders the main sales format. For purchase comparisons, ask which package, tax, delivery and available volume the quote covers.
歐盟公佈部分商用熱泵洗衣設備的限期豁免
Regulation (EU) 2026/2520 was published on 16 November and applies from 1 January 2027. Eligibility depends on appliance type, rated heat-pump capacity and operating conditions.
Article 1 covers specified appliances using F-gases with GWP ≥150. Tumble dryers rated at up to 10 kW qualify through 2028 if designed to run continuously throughout the day and if drying takes no longer than one hour. For tumble dryers rated above 10 kW through 50 kW and washer-dryers in that power range with 15–40 kg laundry capacity, the deadline is the end of 2030. Article 1 treats the above 10 to 12 kW and above 12 to 50 kW bands separately. Check the applicable paragraph and labelling requirements for the model.
The indoor monoblock exemption covered last week has a separate text, (EU) 2026/2486. It applies in 2027 to specified indoor brine-to-water or water-to-water units rated above 20 through 50 kW and specified indoor air-to-water units with separate outdoor-air intake and exhaust ducts rated up to 12 kW. Both categories are subject to the Article 12(2) labelling condition.
英國確認下一財年鍋爐升級補助預算
In a written answer on 18 November, the UK government confirmed £400 million for 2027–28. September application counts alone cannot establish when the budget will be fully committed.
書面答覆指出,補助券金額、實際兌付比例和從申請到兌付的時間都會影響進度。Ofgem 的安裝商指南說明了預算用盡後可能啓用的排隊機制。
計劃適用於英格蘭和威爾士符合條件的物業。將補貼計入項目預算前,應和安裝商覈對物業和設備資格,以及補助券狀態。
印度提出約 400 kW CO₂ 工藝供熱示範
A Multilateral Fund meeting paper dated 17 November describes a transcritical CO₂ water-to-water heat-pump pilot. The funding decision and site selection are pending.
The proposed system would replace an ageing R134a heat pump at an industrial site with steady demand for 70–90°C process water. The proposal calls for measuring energy and flow on the existing system before replacement, then comparing performance at the selected site.
The executive committee is scheduled to meet on 7–11 December. Paragraph 143 gives two different annual energy savings figures. Wait for a reconciled baseline and metered results before using the proposal’s estimates for project economics.
聯合國環境規劃署公佈可持續製冷新支持
On 17 November, UNEP said countries and partners had announced more than US$20 million in new support for the Global Cooling Pledge, alongside work on a voluntary roadmap.
The announcement follows the cooling ministerial event and its Antalya communiqué of 16 November. The voluntary roadmap is intended to help countries map heat risk and cooling needs, choose local measures and identify ways to finance them.
冷鏈或製冷項目可待執行計劃公佈後覈對支持範圍、資格和申請日期。本次公告給出的是各方承諾支持的總額。
接下來哪天
Standards check on 22 November. China’s public standards portal lists GB/T 18837-2026 and GB/T 27941-2026 as in force from 1 November. The product standard record also links Amendment No. 1. The Ministry of Ecology and Environment’s list includes the 2027 allocation plan. Check it again for the issuance notice and company-level allocations.
- 16 November: EU Official Journal publishes the commercial-laundry exemption. It applies from 1 January 2027.
- 17–18 November: The Multilateral Fund issues the India proposals paper. The UK government answers Parliament on the next-year boiler upgrade budget.
- 25 November: GEOFLEXheat online webinar on geothermal heat recovery and scaling control.
- 1 December: EHPA Heat Pump Forum and Awards, Brussels.
- 2 December, 15:00–16:30 CET: IEA HPT Project 68 online webinar on high-temperature heat pumps in food drying.
- 7–11 December: The Multilateral Fund Executive Committee’s 99th meeting is scheduled in Montreal.
出處
- OilChem market note, 17 November
- Mysteel market hub, reprinting OilChem’s 20 November East China quotations
- Fluorine Online, Yonghe R32, 18 November
- Fluorine Online, Sanmei R32, 18 November
- Fluorine Online, Dongyue R32, 19 November
- Fluorine Online, Dongyang R32, 19 November
- Fluorine Online, Quzhou Juhua R22, 18 November
- Official Journal of the EU, Implementing Regulation (EU) 2026/2520, Articles 1–2
- EUR-Lex, Implementing Regulation (EU) 2026/2486, Articles 1–2
- UK Parliament, written answer on the Boiler Upgrade Scheme, 18 November
- Ofgem, installer guidance V5.2
- GOV.UK, Boiler Upgrade Scheme overview and geographic scope
- Multilateral Fund, India proposals, UNEP/OzL.Pro/ExCom/99/56, paragraphs 112–150
- UNEP, 17 November press release on heat resilience and cooling
- Cool Coalition, Antalya cooling ministerial communiqué
- SAMR, GB/T 18837-2026 status and Amendment No. 1 reference
- SAMR, GB/T 27941-2026 status
- Ministry of Ecology and Environment, ODS and HFC notices
- Japanese Standards Association, November publication listings
- EHPA, GEOFLEXheat webinar, 25 November
- EHPA, Heat Pump Forum and Awards, 1 December
- IEA HPT Project 68, food-drying webinar, 2 December
本期要点
- 华东 R32 报价区间持稳 隆众资讯 11 月 17 日和 20 日的华东报价均显示,R32 为 6.35–6.45 万元/吨,制冷剂级 R22 为 1.7 万元/吨。
- 所查 R32 厂家报盘为 6.4–6.6 万元/吨 11 月 18–19 日公布的部分厂家报盘有差异,实际采购还要看各厂的供货条件。
- 欧盟公布部分商用热泵洗衣设备的限期豁免 欧盟于 11 月 16 日公布实施条例 (EU) 2026/2520,自 2027 年 1 月 1 日起适用。能否适用取决于设备类型、热泵额定容量和运行条件。
- 英国确认下一财年锅炉升级补助预算 英国政府 11 月 18 日书面确认,2027–28 财年预算为 4 亿英镑。仅凭 9 月申请量无法判断预算何时用完。
- 印度提出约 400 kW CO₂ 工艺供热示范 蒙特利尔议定书多边基金 11 月 17 日的会议文件提出跨临界 CO₂ 水–水热泵示范。资金审批和现场选址仍待完成。
- 联合国环境规划署公布可持续制冷新支持 联合国环境规划署 11 月 17 日表示,各国和合作伙伴宣布为落实《全球制冷承诺》提供超过 2,000 万美元的新支持,并推进自愿路线图。
华东 R32 报价区间持稳
隆众资讯 11 月 17 日和 20 日的华东报价均显示,R32 为 6.35–6.45 万元/吨,制冷剂级 R22 为 1.7 万元/吨。
两个时点的 R125 报价均为 5.2–5.3 万元/吨,R410A 5.5–5.6 万元/吨,R134a 6.35–6.5 万元/吨。11 月 17 日早报中,R125 和 R410A 主流参考价较前一工作日时点分别回落 2,500 元/吨和 4,000 元/吨。
11 月 17 日数据来自隆众早报,20 日数据来自我的钢铁网转载。两组数字均为时点出厂参考价。用于采购预算前,应按同一品级、包装和交货条件比较。
所查 R32 厂家报盘为 6.4–6.6 万元/吨
11 月 18–19 日公布的部分厂家报盘有差异,实际采购还要看各厂的供货条件。
氟务在线 11 月 18 日记录永和 R32 报 6.4 万元/吨、三美报 6.55 万元/吨。19 日记录东岳报 6.55 万元/吨、东阳光报 6.6 万元/吨。三美为内外贸对外报价,东阳光货源主要供合约客户。
11 月 18 日的衢州巨化 R22 报盘为 1.7 万元/吨,实际执行价一单一谈,供货以小钢瓶为主。询价时应确认包装、含税情况、交货条件和可供数量。
欧盟公布部分商用热泵洗衣设备的限期豁免
欧盟于 11 月 16 日公布实施条例 (EU) 2026/2520,自 2027 年 1 月 1 日起适用。能否适用取决于设备类型、热泵额定容量和运行条件。
第 1 条涉及使用 GWP≥150 含氟气体的指定设备。热泵额定容量 不超过 10 kW 的滚筒烘干机,须设计为全天连续运行且烘干时间不超过一小时,豁免至 2028 年底。额定容量 大于 10 kW 且不超过 50 kW 的滚筒烘干机,以及处于同一功率范围、洗涤容量为 15–40 kg 的洗烘一体机,豁免至 2030 年底。第 1 条分别规定 大于 10 至 12 kW 和 大于 12 至 50 kW 两档,具体机型应核对适用款项和标签要求。
上周提到的室内整体式热泵豁免,已核到单独的 (EU) 2026/2486 正文。该条例在 2027 年适用,涵盖额定容量 大于 20 kW 且不超过 50 kW 的指定室内盐水源或水源热泵,以及额定容量 不超过 12 kW、设有独立室外空气进、排风管的指定室内空气源热泵。两类均须符合第 12(2) 条标签条件。
英国确认下一财年锅炉升级补助预算
英国政府 11 月 18 日书面确认,2027–28 财年预算为 4 亿英镑。仅凭 9 月申请量无法判断预算何时用完。
书面答复指出,补助券金额、实际兑付比例和从申请到兑付的时间都会影响进度。Ofgem 的安装商指南说明了预算用尽后可能启用的排队机制。
计划适用于英格兰和威尔士符合条件的物业。将补贴计入项目预算前,应和安装商核对物业和设备资格,以及补助券状态。
印度提出约 400 kW CO₂ 工艺供热示范
蒙特利尔议定书多边基金 11 月 17 日的会议文件提出跨临界 CO₂ 水–水热泵示范。资金审批和现场选址仍待完成。
拟用该系统替换一台老旧 R134a 热泵,候选厂需有稳定的 70–90°C 工艺热水需求。方案要求在更换前测量原系统能耗和流量,再用选定现场的数据比较运行表现。
执行委员会拟于 12 月 7–11 日开会。文件第 143 段列出两个不同的年节电量。用于项目经济性判断前,应等基线与估算口径核对,并取得现场计量结果。
联合国环境规划署公布可持续制冷新支持
联合国环境规划署 11 月 17 日表示,各国和合作伙伴宣布为落实《全球制冷承诺》提供超过 2,000 万美元的新支持,并推进自愿路线图。
这项消息接续 11 月 16 日制冷部长级会议及其《安塔利亚公报》。自愿路线图旨在协助各国识别高温风险和制冷需求、选择适合当地的措施,并寻找资金来源。
冷链或制冷项目可待执行计划公布后核对支持范围、资格和申请日期。本次公告给出的是各方承诺支持的总额。
接下来哪天
11 月 22 日核对标准。国家标准全文公开系统显示,GB/T 18837-2026 和 GB/T 27941-2026 均自 11 月 1 日起实施,产品标准条目另列第 1 号修改单。生态环境部目录已列 2027 年配额分配方案,企业配额应以其后续核发公告为准。
- 11 月 16 日 欧盟官方公报发布商用洗衣设备豁免,2027 年 1 月 1 日起适用。
- 11 月 17–18 日 多边基金发布印度项目建议书,英国政府书面回复下一财年锅炉升级补助预算问题。
- 11 月 25 日 GEOFLEXheat 线上研讨会,讨论地热余热利用和结垢控制。
- 12 月 1 日 欧洲热泵论坛与颁奖活动,布鲁塞尔。
- 12 月 2 日 22:00–23:30(北京时间) IEA HPT Project 68 食品干燥高温热泵线上研讨会。
- 12 月 7–11 日 蒙特利尔议定书多边基金执行委员会第 99 次会议拟在蒙特利尔举行。
出处
- 隆众资讯制冷剂早报,11 月 17 日
- 我的钢铁网制冷剂市场专题,转载隆众资讯 11 月 20 日华东报价
- 氟务在线,11 月 18 日永和 R32 报价
- 氟务在线,11 月 18 日三美 R32 报价
- 氟务在线,11 月 19 日东岳 R32 报价
- 氟务在线,11 月 19 日东阳光 R32 报价
- 氟务在线,11 月 18 日衢州巨化 R22 报价
- 欧盟官方公报,实施条例 (EU) 2026/2520 第 1–2 条
- EUR-Lex,实施条例 (EU) 2026/2486 第 1–2 条
- 英国议会,11 月 18 日锅炉升级计划书面答复
- Ofgem,安装商指南 V5.2
- 英国政府,锅炉升级计划及适用地区
- 蒙特利尔议定书多边基金,印度项目建议书 UNEP/OzL.Pro/ExCom/99/56,第 112–150 段
- 联合国环境规划署,11 月 17 日高温韧性与可持续制冷新闻稿
- 制冷联盟,安塔利亚制冷部长级会议公报
- 国家标准全文公开系统,GB/T 18837-2026 状态及第 1 号修改单入口
- 国家标准全文公开系统,GB/T 27941-2026 状态
- 生态环境部,消耗臭氧层物质和氢氟碳化物通知目录
- 日本规格协会,11 月发行目录
- 欧洲热泵协会,11 月 25 日 GEOFLEXheat 研讨会
- 欧洲热泵协会,12 月 1 日热泵论坛与颁奖
- IEA HPT Project 68,12 月 2 日食品干燥研讨会