Tienen 糖廠:4 MW 熱泵回收蒸發餘熱再供蒸汽

Belgian sugar-refining installation: the November 2025 IEA HPT card records commissioning operation and subsequent compressor operation at full capacity. Annual benefits remain estimates.

Run detailed calculation with this case

工程數據

案例類型
公開來源案例 — 數據來自公開報告、論文或廠商資料
數據狀態
公開來源案例
數據來源
Raffinerie Tirlemontoise, 19 Feb 2025: https://www.raffinerietirlemontoise.com/en/news/2025-02-european-first-raffinerie-tirlemontoise-introduces-innovative-industrial-heat-pump — SPIRIT DS2 design/testing poster: https://spirit-heat.eu/wp-content/uploads/2025/04/DS2-poster-1.pdf — Reviewed 2 Nov 2026. — IEA HPT Project 68, demo13, November 2025 (supplier-provided, not third-party validated): https://heatpumpingtechnologies.org/content/uploads/sites/81/2025/12/demo13spiritgea20251112.pdf
審閱 / 日期
Editorial (Open Thermal AI) · 2026-11-02
行業
食品
熱源溫度
75°C
熱匯溫度
138°C
溫升
≈ 63 K
供熱/製冷負荷
4000 kW
架構
採用 GEA 螺桿壓縮機的閉式正戊烷熱泵,回收蒸汽熱量再製蒸汽。
結果狀態
The November 2025 IEA HPT card reports part-load commissioning followed by full compressor capacity after modifications; heating COP still awaited validation.
Key risk
Owner quotes COP 3–5, but the later IEA HPT card still marks COP pending validation. Commissioning operation is not long-term acceptance; carbon savings are estimates.
原有系統
化石燃料供汽用於糖液多效蒸發。
製冷劑
R601
COP
未披露
年度節能 / 減排
Owner forecast: 3,000–3,500 t/year CO₂ avoided; not a published metered annual outcome.
預計回收期
所覈對來源未披露。

項目背景

SPIRIT 示範將熱泵技術開發與既有製糖工藝銜接。

敘述性輸入

後續案例卡列 75°C 真空蒸汽、138°C 供汽及最高 4 MW 制熱;早期 SPIRIT 設計海報另列副榨季 114°C 工況。

熱泵方案

閉式 R601 循環提升蒸發餘熱,並非直接再壓縮工藝蒸氣。案例卡還記錄正戊烷裝置的氣體檢測、通風和防靜電措施。

COP 與節能

The case card describes oil, valve and vacuum-line improvements, then full compressor operation. Its operating-hours field remains “in commissioning”; the earlier 2,000-hour test target is not a completed record.

投資回報要點

投資與回收期未披露。應分別覈算不同榨季,再彙總全年供熱、用電及排放。

FAQ

對照自己的現場,下一步覈對什麼?

記錄熱源與用熱溫度、同時段負荷、備用供熱和全系統用電,再用當地能源價格覈算費用。本案例不構成性能保證。