現場準備單
蒸發濃縮工況準備單
選定一臺設備或一道工序,按項記錄。未掌握的數據留空,資料和原理在下方繼續閱讀。
電子填寫需要啓用 JavaScript。以下空白單仍可通過瀏覽器打印,原指南繼續保留。
打印空白單
Open Thermal AI · Blank sheet
蒸發濃縮工況準備單
Sheet ID: ________________ · Template version: 2026-10-18.1
- 工廠/車間
- 設備名稱或編號 / 工序名稱
- 記錄人
- 調查日期
閉式熱泵與開式蒸汽再壓縮須分別覈查。本單不確定蒸發器或壓縮機規格;壓力基準、工藝限制和未知的沸點升高須先確認。
已記錄不等於已覈實。填寫完成不代表安全合格、項目可行或節能收益;專業人員仍需複覈。
| EV-01 · Identify the evaporator system · ________ | |
|---|---|
| 設備位號、效數、加熱蒸汽/二次蒸汽/凝結水連接 Where to look; what to do if missing: Start from the flow diagram; clarify missing connections first. 設備編號(位號)通常在現場標籤或圖紙上。沒有編號時先寫設備名稱和位置,並註明編號待確認,不必編造正式編號。 | |
| 設備效數 | |
| 進汽/二次蒸汽/凝結水連接 | |
| 記錄狀態 | □ Not reviewed □ Recorded □ Needs measurement □ Needs confirmation □ Not applicable (explain) |
| 資料類型 | |
| 資料編號/來源說明 | |
| 測點/對象位置 | |
| 記錄時間或起止週期 | |
| 運行狀態(生產/清洗/待機等) | |
| 備註/關聯準備單編號 | |
| 待辦負責人 | |
| 約定完成日期 | |
| 不適用的原因 | |
| 複覈人、日期與意見(由人填寫) | |
| EV-02 · Check feed and product data · ________ | |
|---|---|
| Composition, mass flow, temperature and concentration with its definition. Where to look; what to do if missing: Use process/laboratory records; confirm unknown composition. | |
| 物料組成 | |
| 進出料量及單位 | |
| Feed/product temperatures (°C) | |
| 濃度及定義 | |
| 記錄狀態 | □ Not reviewed □ Recorded □ Needs measurement □ Needs confirmation □ Not applicable (explain) |
| 資料類型 | |
| 資料編號/來源說明 | |
| 測點/對象位置 | |
| 記錄時間或起止週期 | |
| 運行狀態(生產/清洗/待機等) | |
| 備註/關聯準備單編號 | |
| 待辦負責人 | |
| 約定完成日期 | |
| 不適用的原因 | |
| 複覈人、日期與意見(由人填寫) | |
| EV-03 · Read process pressure and temperature · ________ | |
|---|---|
| Pressure and reference basis for each effect, temperature and time. Where to look; what to do if missing: Use instruments and trends; do not convert an undefined vacuum reading. | |
| 各效壓力及單位 | |
| 壓力/真空讀數基準 | |
| Temperature of each effect (°C) | |
| 記錄狀態 | □ Not reviewed □ Recorded □ Needs measurement □ Needs confirmation □ Not applicable (explain) |
| 資料類型 | |
| 資料編號/來源說明 | |
| 測點/對象位置 | |
| 記錄時間或起止週期 | |
| 運行狀態(生產/清洗/待機等) | |
| 備註/關聯準備單編號 | |
| 待辦負責人 | |
| 約定完成日期 | |
| 不適用的原因 | |
| 複覈人、日期與意見(由人填寫) | |
| EV-04 · Check heating-steam consumption · ________ | |
|---|---|
| 壓力、溫度、計量量 t/週期或 t/h、凝結水去向 Where to look; what to do if missing: Use submeters and logs, not the whole-plant steam bill. | |
| 加熱蒸汽壓力和基準 | |
| Heating-steam temperature (°C) | |
| 耗汽量及週期 | |
| Condensate destination | |
| 記錄狀態 | □ Not reviewed □ Recorded □ Needs measurement □ Needs confirmation □ Not applicable (explain) |
| 資料類型 | |
| 資料編號/來源說明 | |
| 測點/對象位置 | |
| 記錄時間或起止週期 | |
| 運行狀態(生產/清洗/待機等) | |
| 備註/關聯準備單編號 | |
| 待辦負責人 | |
| 約定完成日期 | |
| 不適用的原因 | |
| 複覈人、日期與意見(由人填寫) | |
| EV-05 · Check secondary-vapor conditions and use · ________ | |
|---|---|
| 溫度、壓力、已知流量、夾帶/非凝氣資料、已有利用 Where to look; what to do if missing: Use process diagrams and records; unknown vapor is not confirmed suitable for recompression. | |
| Secondary-vapor temperature (°C) | |
| 壓力及基準 | |
| 已知流量及單位 | |
| 夾帶/非凝氣及已有用途 | |
| 記錄狀態 | □ Not reviewed □ Recorded □ Needs measurement □ Needs confirmation □ Not applicable (explain) |
| 資料類型 | |
| 資料編號/來源說明 | |
| 測點/對象位置 | |
| 記錄時間或起止週期 | |
| 運行狀態(生產/清洗/待機等) | |
| 備註/關聯準備單編號 | |
| 待辦負責人 | |
| 約定完成日期 | |
| 不適用的原因 | |
| 複覈人、日期與意見(由人填寫) | |
| EV-06 · Confirm process temperature constraints · ________ | |
|---|---|
| 允許溫度、停留時間、沸點升高及對應濃度 Where to look; what to do if missing: Use process tests/documents; leave unmeasured values unknown. | |
| 允許溫度與停留時間 | |
| 沸點升高及對應濃度 | |
| 記錄狀態 | □ Not reviewed □ Recorded □ Needs measurement □ Needs confirmation □ Not applicable (explain) |
| 資料類型 | |
| 資料編號/來源說明 | |
| 測點/對象位置 | |
| 記錄時間或起止週期 | |
| 運行狀態(生產/清洗/待機等) | |
| 備註/關聯準備單編號 | |
| 待辦負責人 | |
| 約定完成日期 | |
| 不適用的原因 | |
| 複覈人、日期與意見(由人填寫) | |
| EV-07 · Record production and cleaning cycles · ________ | |
|---|---|
| 生產/清洗/停機時段、結垢或腐蝕情況 Where to look; what to do if missing: Use shift and maintenance logs; separate normal and abnormal conditions. Overlap hours are the times when source heat is available and the process needs heat simultaneously. Compare both operating logs. Do not assume 8,760 hours or use only one side’s running hours. Storage for mismatched timing needs separate assessment. | |
| 生產/清洗/停機時段 | |
| 結垢與腐蝕記錄 | |
| 記錄狀態 | □ Not reviewed □ Recorded □ Needs measurement □ Needs confirmation □ Not applicable (explain) |
| 資料類型 | |
| 資料編號/來源說明 | |
| 測點/對象位置 | |
| 記錄時間或起止週期 | |
| 運行狀態(生產/清洗/待機等) | |
| 備註/關聯準備單編號 | |
| 待辦負責人 | |
| 約定完成日期 | |
| 不適用的原因 | |
| 複覈人、日期與意見(由人填寫) | |
| EV-08 · Check existing steam reuse · ________ | |
|---|---|
| 多效/TVR/MVR/直接回收;驅動與輔助電耗資料 Where to look; what to do if missing: Use equipment records; do not count already recovered steam twice. | |
| 既有多效/TVR/MVR/回收方式 | |
| 驅動和輔助電耗 | |
| 記錄狀態 | □ Not reviewed □ Recorded □ Needs measurement □ Needs confirmation □ Not applicable (explain) |
| 資料類型 | |
| 資料編號/來源說明 | |
| 測點/對象位置 | |
| 記錄時間或起止週期 | |
| 運行狀態(生產/清洗/待機等) | |
| 備註/關聯準備單編號 | |
| 待辦負責人 | |
| 約定完成日期 | |
| 不適用的原因 | |
| 複覈人、日期與意見(由人填寫) | |
先選一臺蒸發或濃縮設備
Choose one evaporator, concentrator or still. Record what it removes and which steam supply serves it. A plant steam total can feed several duties, so it cannot set the share this one step could change. Tonnes of steam are a mass, not useful heat. Pressure, condensate return and the system boundary also have to be known.
閉式熱泵和開式蒸汽再壓縮不是同一條路
A closed-cycle electric heat pump uses electricity to lift a lower-temperature source up to steam or process heat. Open mechanical vapor recompression takes vapor the process itself produces and sends it back as the heating steam. The two are not interchangeable. Neither is chosen until the vapor state, the temperatures the process allows, and the process constraints are known.
Do not change the specified heating utility without process review. A boiling-point rise that has not been measured stays blank; do not fill it in from a similar product.
先準備這幾類資料
- Material, and whether the step removes water or another component.
- Steam pressure or vacuum, and whether steam touches the product or heats through a surface.
- Feed and product conditions when they are known. Leave boiling-point rise blank when it is not measured.
- Operating hours, including cleaning and shutdown.
- Condensate recovery that already exists.
選擇下一步
Sketch the evaporator and mark steam in, vapor out and condensate. Review the steam and MVR pathway with your process team. If you are evaluating a closed-cycle electric heat pump and have temperatures, load, operating hours and prices, you can estimate its annual heating costs. This estimate cannot calculate open-cycle MVR electricity use or size the evaporator or compressor.
依據與使用邊界
This is an editorial learning guide, not a plant audit or a measured savings result. Site inputs remain unknown until supplied and checked. Detailed design, procurement, hygienic and pressure-equipment decisions require qualified review. Read our editorial principles.
现场准备单
蒸发浓缩工况准备单
选定一台设备或一道工序,按项记录。未掌握的数据留空,资料和原理在下方继续阅读。
电子填写需要启用 JavaScript。以下空白单仍可通过浏览器打印,原指南继续保留。
打印空白单
Open Thermal AI · 空白准备单
蒸发浓缩工况准备单
准备单编号: ________________ · 模板版本: 2026-10-18.1
- 工厂/车间
- 设备名称或编号 / 工序名称
- 记录人
- 调查日期
闭式热泵与开式蒸汽再压缩须分别核查。本单不确定蒸发器或压缩机规格;压力基准、工艺限制和未知的沸点升高须先确认。
已记录不等于已核实。填写完成不代表安全合格、项目可行或节能收益;专业人员仍需复核。
| EV-01 · 标出本次设备和系统 · ________ | |
|---|---|
| 设备位号、效数、加热蒸汽/二次蒸汽/凝结水连接 去哪里查;缺失时怎么办: 流程图;连接不清楚先补图 设备编号(位号)通常在现场标签或图纸上。没有编号时先写设备名称和位置,并注明编号待确认,不必编造正式编号。 | |
| 设备效数 | |
| 进汽/二次蒸汽/凝结水连接 | |
| 记录状态 | □ 未查看 □ 已记录 □ 待补测 □ 待确认 □ 不适用(须说明) |
| 资料类型 | |
| 资料编号/来源说明 | |
| 测点/对象位置 | |
| 记录时间或起止周期 | |
| 运行状态(生产/清洗/待机等) | |
| 备注/关联准备单编号 | |
| 待办负责人 | |
| 约定完成日期 | |
| 不适用的原因 | |
| 复核人、日期与意见(由人填写) | |
| EV-02 · 查进料与产品记录 · ________ | |
|---|---|
| 物料组成;流量 kg/h、温度 °C、浓度及定义 去哪里查;缺失时怎么办: 工艺记录/化验;未知组成先核实 | |
| 物料组成 | |
| 进出料量及单位 | |
| 进出料温度 (°C) | |
| 浓度及定义 | |
| 记录状态 | □ 未查看 □ 已记录 □ 待补测 □ 待确认 □ 不适用(须说明) |
| 资料类型 | |
| 资料编号/来源说明 | |
| 测点/对象位置 | |
| 记录时间或起止周期 | |
| 运行状态(生产/清洗/待机等) | |
| 备注/关联准备单编号 | |
| 待办负责人 | |
| 约定完成日期 | |
| 不适用的原因 | |
| 复核人、日期与意见(由人填写) | |
| EV-03 · 查工艺压力与温度 · ________ | |
|---|---|
| 各效压力及压力基准、温度 °C、时间 去哪里查;缺失时怎么办: 现有仪表与趋势;真空度定义不明时不直接换算 | |
| 各效压力及单位 | |
| 压力/真空读数基准 | |
| 各效温度 (°C) | |
| 记录状态 | □ 未查看 □ 已记录 □ 待补测 □ 待确认 □ 不适用(须说明) |
| 资料类型 | |
| 资料编号/来源说明 | |
| 测点/对象位置 | |
| 记录时间或起止周期 | |
| 运行状态(生产/清洗/待机等) | |
| 备注/关联准备单编号 | |
| 待办负责人 | |
| 约定完成日期 | |
| 不适用的原因 | |
| 复核人、日期与意见(由人填写) | |
| EV-04 · 查加热蒸汽消耗 · ________ | |
|---|---|
| 压力、温度、计量量 t/周期或 t/h、凝结水去向 去哪里查;缺失时怎么办: 分表与日志;全厂蒸汽账单不当单机耗汽 | |
| 加热蒸汽压力和基准 | |
| 加热蒸汽温度 (°C) | |
| 耗汽量及周期 | |
| 凝结水去向 | |
| 记录状态 | □ 未查看 □ 已记录 □ 待补测 □ 待确认 □ 不适用(须说明) |
| 资料类型 | |
| 资料编号/来源说明 | |
| 测点/对象位置 | |
| 记录时间或起止周期 | |
| 运行状态(生产/清洗/待机等) | |
| 备注/关联准备单编号 | |
| 待办负责人 | |
| 约定完成日期 | |
| 不适用的原因 | |
| 复核人、日期与意见(由人填写) | |
| EV-05 · 查二次蒸汽状态与去向 · ________ | |
|---|---|
| 温度、压力、已知流量、夹带/非凝气资料、已有利用 去哪里查;缺失时怎么办: 工艺图/运行资料;未知不得推定可再压缩 | |
| 二次蒸汽温度 (°C) | |
| 压力及基准 | |
| 已知流量及单位 | |
| 夹带/非凝气及已有用途 | |
| 记录状态 | □ 未查看 □ 已记录 □ 待补测 □ 待确认 □ 不适用(须说明) |
| 资料类型 | |
| 资料编号/来源说明 | |
| 测点/对象位置 | |
| 记录时间或起止周期 | |
| 运行状态(生产/清洗/待机等) | |
| 备注/关联准备单编号 | |
| 待办负责人 | |
| 约定完成日期 | |
| 不适用的原因 | |
| 复核人、日期与意见(由人填写) | |
| EV-06 · 查工艺温度约束 · ________ | |
|---|---|
| 允许温度、停留时间、沸点升高及对应浓度 去哪里查;缺失时怎么办: 工艺试验或资料;无资料保留待测,不套用相似物料 | |
| 允许温度与停留时间 | |
| 沸点升高及对应浓度 | |
| 记录状态 | □ 未查看 □ 已记录 □ 待补测 □ 待确认 □ 不适用(须说明) |
| 资料类型 | |
| 资料编号/来源说明 | |
| 测点/对象位置 | |
| 记录时间或起止周期 | |
| 运行状态(生产/清洗/待机等) | |
| 备注/关联准备单编号 | |
| 待办负责人 | |
| 约定完成日期 | |
| 不适用的原因 | |
| 复核人、日期与意见(由人填写) | |
| EV-07 · 记录清洗与运行周期 · ________ | |
|---|---|
| 生产/清洗/停机时段、结垢或腐蚀情况 去哪里查;缺失时怎么办: 班报/检修记录;分别保留正常与异常工况 同时运行时间是余热可用、工序又需要热的共同时间。对照两侧运行记录逐段核对;不能直接填全年 8760 小时,也不能只用一侧的开机小时。储热能否弥补错峰须另行核实。 | |
| 生产/清洗/停机时段 | |
| 结垢与腐蚀记录 | |
| 记录状态 | □ 未查看 □ 已记录 □ 待补测 □ 待确认 □ 不适用(须说明) |
| 资料类型 | |
| 资料编号/来源说明 | |
| 测点/对象位置 | |
| 记录时间或起止周期 | |
| 运行状态(生产/清洗/待机等) | |
| 备注/关联准备单编号 | |
| 待办负责人 | |
| 约定完成日期 | |
| 不适用的原因 | |
| 复核人、日期与意见(由人填写) | |
| EV-08 · 查已有蒸汽再利用方式 · ________ | |
|---|---|
| 多效/TVR/MVR/直接回收;驱动与辅助电耗资料 去哪里查;缺失时怎么办: 设备图纸及记录;避免重复计算已回收蒸汽 | |
| 既有多效/TVR/MVR/回收方式 | |
| 驱动和辅助电耗 | |
| 记录状态 | □ 未查看 □ 已记录 □ 待补测 □ 待确认 □ 不适用(须说明) |
| 资料类型 | |
| 资料编号/来源说明 | |
| 测点/对象位置 | |
| 记录时间或起止周期 | |
| 运行状态(生产/清洗/待机等) | |
| 备注/关联准备单编号 | |
| 待办负责人 | |
| 约定完成日期 | |
| 不适用的原因 | |
| 复核人、日期与意见(由人填写) | |
先选一台蒸发或浓缩设备
先选一台蒸发器、浓缩设备或蒸馏釜,记下它除去什么、由哪路蒸汽供热。全厂蒸汽总量往往供给多个环节,不能直接当成这一步可以改掉的份额。蒸汽吨数是质量,不是可用热量;压力、凝结水回流和系统边界也要一起看。
闭式热泵和开式蒸汽再压缩不是同一条路
闭式电驱热泵用电把较低温度的热源提升到蒸汽或工艺热。开式机械蒸汽再压缩取的是工艺自己产生的蒸汽,再送回去作加热蒸汽。两者不能互相替换。蒸汽状态、工艺允许的温度和工艺约束还没弄清之前,先不要选定哪一条。
未经工艺复核,不能更改规定的供热方式。沸点升高没有测过就留空,不要用相近产品的数字填上。
先准备这几类资料
- 物料,以及这一步除去的是水还是其他组分。
- 蒸汽压力或真空度,以及蒸汽是直接接触物料还是通过壁面加热。
- 已知的进料和出料条件。沸点升高没有测量就留空。
- 运行时间,包括清洗和停机。
- 已经在做的凝结水回收。
选择下一步
先画蒸发器简图,标出进汽、二次蒸汽和凝结水,与工艺人员一起核对蒸汽与 MVR 路线。如果评估的是闭式电驱热泵,且已有温度、负荷、运行时数和能源价格,可试算其全年供热费用。试算无法给出开式 MVR 用电量,也无法确定蒸发器或压缩机规格。
依据与使用边界
本文为编辑整理的入门指南,不是现场审计或实测节能成果。现场数据在提供并核对前保持未知。详细设计、采购、卫生与压力设备事项需要合格专业人员复核。参见编辑原则。