主な更新情報

  1. China 1 Jul ODS cluster in week four: HCFC-141b spray, XPS foam and HCFC solvent bans under continued inspection; FAS 2026/550 next milestone 1 Aug 家庭用太陽光式給湯ラベル(約6日);2027年度ODS/HFCの割当額案の草案はコメント待ちのままである――掲載予定 31 Oct 2026
  2. Coalition of 19 attorneys general + New York City file DC Circuit petition (21 Jul) challenging EPA Technology Transitions reconsideration—temporary commercial-refrigeration GWP rise to 1,400 (2027–2032) and related deadline relief; rule effective 27 Jul (このブリーフィングから1日)
  3. Carrier (23 Jul) acquires Minneapolis-based 75F: cloud-native, wireless, AI-enabled building automation—integration path into WebCTRL / Abound / Nlyte and QuantumLeap data-centre thermal suite
  4. Systemair (23 Jul) acquires Canada’s Temspec (~EUR 18m FY24/25 revenue, ~90 staff, Mississauga): decentralised HVAC for schools and multi-storey buildings—aims to lead North American school ventilation
  5. Keyter Arion eco KZTB water-to-water HTHP (Spain, coverage 25 Jul): R-1234ze, 584–2,200 kW, hot water to 87°C; dual inverter Bitzer screws, twin circuits, series shell-and-tube condensers with subcoolers for large lifts
ポリシー

ポリシーと規制

  • China’s 1 Jul ODS regulatory cluster entered its fourth enforcement week. Ecology departments continue site checks on cold-room, logistics and industrial insulation projects where HCFC-141b polyurethane spray foam, XPS foam HCFC blowing agents and selected HCFC solvents remain prohibited under the 2025 MEE announcements detailed since week 27. Peak-summer delivery keeps HFO/hydrocarbon blowing-agent substitution and recovery documentation under pressure. The MEE 2027 ODS/HFC quota draft (week 24)—including the raised HFC-245fa cross-category transfer cap—remains in public comment; 2027 quota and initial transfer filings are due 31 Oct 2026.
  • US litigation over the EPA Technology Transitions reconsideration intensified six days before the rule’s effective date. On 21 Jul a coalition of 19 attorneys general (co-led by California, Massachusetts and Washington) plus New York City petitioned the DC Circuit, arguing the May final rule is arbitrary and contrary to the AIM Act—especially the interim GWP limit of 1,400 for supermarket and remote-condensing retail food systems from 2027 through 2032 and the shortened lead time before deadline changes take effect. The rule still becomes effective 27 Jul 2026 (~1 day from this briefing): pre-2025 residential/light-commercial R-410A inventory may continue to be installed until depleted, while industry suits (HARDI/ACCA/PHCC, AHRI and allies from weeks 27–29) and the new state petition proceed in parallel.
  • In Europe, Spanish food-retail association ASEDAS (coverage 22–23 Jul) called for revising F-Gas (EU) 2024/573, citing high-ambient cooling needs, an estimated €2.5bn retrofit bill, ~10,000 missing technicians and transitional-gas scarcity risks—preferring a 2032 horizon over the sector’s four-year path to 2030. EIA and Spanish NGO Ecodes warned that delaying the phasedown would expose retailers to taxed, illegal or contaminated F-gases and that Spain already leads EU natural-refrigerant installer training (~85% of certified installers). Separately, Greek police (24 Jul) arrested a suspect over 25 cylinders (~286 kg) of R-404A and R-134a smuggled from Albania—another F-Gas enforcement reminder as quota pressure rises.
市場

市場と産業

  • Carrier Global (23 Jul) acquired 75F, the Minneapolis innovator behind cloud-native, wireless, AI-enabled building automation—already sampled via Carrier ClimaVision. Terms were undisclosed; the strategic pitch is end-to-end intelligent buildings from applied systems and data centres to light-commercial retrofits. Carrier plans to fold 75F’s generative/agentic AI and auto-commissioning into WebCTRL, Abound, Nlyte and the QuantumLeap thermal-management suite—pairing equipment with a unified data/AI layer rather than leaving controls as a minority venture stake.
  • On the same day, Systemair AB closed its purchase of Temspec Inc. (Mississauga, Ontario): ~90 employees, ~EUR 18m (~CAD 29m) FY24/25 revenue and EBIT margin above Systemair’s target. Temspec’s decentralised HVAC focus—schools and multi-storey buildings, energy efficiency and low noise—folds into Systemair’s ~555-person North American organisation. CEO Robert Larsson framed the deal as making Systemair the “undisputed leader” in school ventilation with a ready sales-rep network. The twin M&A headlines (Carrier software/controls; Systemair school/decentralised HVAC) sit alongside week-29’s Daikin NEXIO Max rooftop and Beijer Ref Q2 strength as North American channel consolidation continues into the EPA TT effective window.
基準

基準とコンプライアンス

  • FAS 2026/550の次のカタログのマイルストーンは以下の通りです 1 Aug 2026 for household solar water heating system energy labels—about six days from this briefing—while projector labels remain in force from 1 Jul. Firms must keep dual catalogues (FAS 2025/45 for heat-pump and chiller units vs 2026/550 for appliances, lighting, projectors and soon solar water heaters) with SKU-level traceability. Looking further, GB/T 18837-2026 for multi-split air-conditioning (heat pump) units takes effect 1 Nov 20262015年版に代わる。 中国エネルギー・ラベルスケジュールに関する本サイトのヒートポンプ規格のクイックリファレンスをご覧ください。
  • 英国のF-ガス対策機関であるREFCOM(BESAが運営する)が登録した 10,000人目 member (23 Jul)—London’s Mayfair Air Conditioning and Refrigeration—amid Building Safety Act scrutiny and surging heat-pump demand. The milestone echoes week-29’s Parts Town UK FCAT1 training signal and the EU’s path to GWP<150 monoblocs by 1 ヤン 2027 (now ~five months) plus handler-certification harmonisation by 11 Mar 2027: 炭化水素やその他の低GWP設備が拡大する中、設置業者の認証能力は依然としてボトルネックとなっている。
技術

技術およびデモンストレーション

  • Keyter (Spain) launched the Arion eco KZTB high-temperature water-to-water heat pump on R-1234ze (coverage 25 Jul): 584–2,200 kW for industrial hot water up to 87°C. Dual inverter-driven Bitzer screw compressors, two independent circuits and series shell-and-tube condensers with integrated subcoolers target high COP under large source–sink lifts while cutting hydraulic flow, pumping energy and install cost. The package sits on the same industrial-HTHP ladder as week-28’s LG Ajin P&P 108°C case and week-29’s DTI Project 68 standardisation narrative—here with an HFO rather than natural-refrigerant choice, underscoring that outlet temperature, lift efficiency and skid standardisation still gate uptake more than thermodynamics alone.
  • シープ 2026(ローマ大学 トール・ヴェルガタ、 20–23 Jul) 産業用ヒートポンプパネル(EHPA(市場概要および統計)と、高温エンド用途向けの高納品温度設計およびCO2ヒートポンプに関するセッション付き)で締められています。 75FのAI/自動コミッショニングによるデータセンターおよび軽量・商用のサーマルスタックに関するCarryerの論文と組み合わせることで、今週の技術スレッドは単一の冷媒に関するものではなく、より迅速な対応を実現する制御機能、大型リフトでCOPを搭載するHTHPスキッド、およびF-GasおよびAIMのタイムラインに追随できるインストーラー認証についての展開性が重視される。
日付

上に来る

  • 今週終了:ローマの 2026 シープ20–23 Jul) with EHPA industrial heat-pump panel; 19 US states + NYC DC Circuit petition vs EPA TT reconsideration (21 Jul); ASEDAS Spanish retail F-Gas revision call and EIA/Ecodes response (22–23 Jul); Carrier acquires 75F (23 Jul); Systemair acquires Temspec (23 Jul); REFCOM 10,000th F-Gas member (23 Jul); Greek HFC smuggling seizure (~286 kg R-404A/R-134a, 24 Jul); Keyter Arion eco KZTB R-1234ze HTHP coverage (25 Jul).
  • 先へ:EPAテクノロジー移行の最終規則が有効 27 Jul 2026 (約1日);FAS 2026/550世帯用太陽光式給湯用ラベル 1 Aug 2026;2027年ODS/HFCの割当額案をパブリックコメントで満たせず—2027年枠および初期移籍届出の提出期限 31 Oct 2026GB/T 18837-2026 マルチスプリット規格の有効性 1 Nov 2026チルヴェンタ2026年ニュルンベルク 13–15 Oct 2026・EUのF-Gas GWP<150の配置禁止措置 1 ヤン 2027F-ガスハンドラー認証の調和 11 Mar 2027.