ポリシーと規制
- China’s 1 Jul ODS regulatory cluster entered its sixth enforcement week. Ecology departments keep site pressure on cold-store, logistics and industrial insulation projects where HCFC-141b spray foam, XPS HCFC blowing agents and selected HCFC solvents remain prohibited under the 2025 MEE announcements tracked since week 27. Peak-summer delivery still stresses HFO/hydrocarbon substitution paperwork and recovery logs. The MEE 2027 ODS/HFC quota draft (week 24)—including the raised HFC-245fa cross-category transfer cap—remains open for comment; 2027 quota and initial transfer filings are due 31 Oct 2026.
- One week after the EPA Technology Transitions reconsideration took effect (27 Jul), trade association commentary sharpened the medium-term supply conflict. ACCA’s 5 Aug analysis notes that interim GWP relief for supermarket/remote-condensing systems (notably the 1,400 ceiling through 2032) and the removal of the residential/light-commercial legacy R-410A install cutoff do not change the AIM Act’s production/consumption schedule—the next big step is still a cut to ~2029年までにベースラインの70%. EPAは以前、さらなる措置を講じることなく、2029年からのHFC需要が配分を上回る可能性があると警告していた。そのため、請負業者やOEMは、今後、より厳しいガスバランスに対して、近い将来に「展開遅れ」に直面する。
- Across the Atlantic, UK enforcement stayed loud. The Environment Agency’s 5 Aug civil-penalty list imposed more than £116,000 on five companies—Celsius Hire (£48,519.10), Krone Trailer UK (£48,000), Emicon-UK (£13,205.70), SL Services Southern (£3,300) and Parkair.UK (£3,000)—mainly for placing pre-charged HFC refrigeration/AC/heat-pump equipment on the GB market without accounting for the charge under F-gas Article 14(1). The same day, ADL Air Conditioning drew a £1,230 適切なF-ガス認証を受けていない活動を行うことに対する罰則。 別に、それ以上 50人の国会議員 (7 Aug) pressed MCS and UKAS to finish air-to-air product/installer accreditation so households can claim the Boiler Upgrade Scheme’s up-to-£2,500 ATAは、すでに法律が有効としているが、バウチャーの発行は依然としてブロックされている。
市場と産業
- Controls and applied thermal demand stayed firm in Europe. Carel Industries (6 Aug) reported first-half 2026 revenue of €370.1m上へ 20.9% 前年比で、低GWP冷凍、ヒートポンプ、データセンター冷却向けのOEMおよびレトロフィットプログラムが、31週目のトレイン予約およびボッシュ–JCIホームコンフォートの終了後も、引き続き部品供給および管理用注文書を管理しているという別のデータです。
- ショーフロアのスケールが秋のカレンダーをリセットします。 チルヴェンタ 2026(取材) 8 Aug既にリストアップ済み 1,095 出展者向け 13–15 Oct in Nuremberg—above 2024’s 1,010 and the prior 2018 peak of 1,019—after organiser NürnbergMesse added Hall 1 and lifted available space to about 85,930 m². The booking surge, two months before doors open, is a leading indicator for who will showcase R290 monobloc platforms, CO₂ retail packs and A2L VRF ahead of the EU 1 ヤン 2027 GWP<150 自主的な配置ルール。
- Project and M&A aftershocks continued to define channel geography. Lu-Ve (coverage 6 Aug) supplied 28 CO₂ air coolers to a newly built ~62 m-high single-storey automated cold store in China—one of the tallest of its type—underscoring Asian cold-chain height and natural-refrigerant hardware. Atlas Copco’s mid-July agreement to acquire Guangdong Euroklimat (industrial chillers/heat pumps; ~RMB 1.28bn 2025 revenue; close targeted in Q3 2026) ボッシュが旧JCIホームコンフォートネットワークをエンドを通じて統合する中、引き続き産業プロセスによるヒートポンプの統合が注目される2027.
基準とコンプライアンス
- China’s energy labelling is now in its second week under FAS 2026/550 and GB 26969-2025 for household solar water-heating systems (in force 1 Aug); pre-1 Aug stock may delay labelling to 1 Aug 2028. Firms still juggle dual catalogues—FAS 2025/45 for heat-pump/chiller units versus 2026/550 for appliances and solar DHW—at SKU level. GB/T 18837-2026 for multi-split air-conditioning (heat pump) units remains on track for 1 Nov 2026.
- Competence and test capacity moved from soft constraint to hard investment. ILK Dresden (8 Aug) is expanding R290 compressor test capability to volumetric flows up to about 48 m³/h欧州連合(EU)を競争させる炭化水素のモノブロックおよび商業用ヒートポンプ計画への直接的な対応 1 ヤン 2027 GWP<150 self-contained placement ban (now under five months). The UK F-gas civil penalties the same week underline that quota accounting for pre-charged imports and handler certification are as binding as thermodynamics; IOR Skills Alliance’s London date (24 Sep 2026) と 11 Mar 2027 ハンドラー認定の調和クロックは変更されていません。
技術およびデモンストレーション
- Commercial VRF on R32 kept shipping new SKUs even as monobloc Europe pivots to hydrocarbons. Clivet (3 Aug) introduced the CVT9 (CVT9-Y) R32 heat-pump outdoor range—five single-module sizes from 25.2~45kW、併用可能 90kW—with EasyCom free-topology bus, IEC 60335-2-40-aligned shut-off valve boxes and leak sensors for small-room indoor installs, EVI inverter scroll, SCOP up to ~4.9 / SEER up to ~8.6, and Eurovent certification. The launch sits beside week 31’s Samsung DVM S2 R32: commercial VRF choosing a lower-GWP HFC platform while EU self-contained ≤50 kW rules push R290 for 2027.
- Natural-refrigerant hardware and field trials filled the applied column. Lu-Ve’s 62 m Chinese CO₂ cold-store cooler package (market section) pairs with Trane’s reported field trials (coverage 6 Aug) of an autonomous solar-powered cold-storage container—another deployability story for off-grid and resilience use cases. On the R&D bench, ILK Dresden’s expanded R290 compressor rigs (standards section) and Danfoss’s Chillventa preview of R290 scroll/vapor-injection packages plus high-temperature industrial heat-pump screws (process temperatures toward 120 °C) OEMがニュルンベルクで発表するコンポーネントスタックをスケッチする。
上に来る
- Completed this week: Clivet CVT9 R32 VRF launch (3 Aug); ACCA post-TT AIM/2029 supply commentary and UK EA F-gas quota/civil penalties incl. ADL certificate fine (5 Aug); Carel H1 results, Lu-Ve China CO₂ coolers, Trane autonomous solar cold-store trials (6 Aug); 50+ MPs letter on ATA heat pumps / BUS accreditation (7 Aug); Chillventa record exhibitor count (1,095) and ILK Dresden R290 test expansion (8 Aug).
- 先へ:IOR産業技能アライアンス・ロンドン 24 Sep 2026チルヴェンタ2026年ニュルンベルク 13–15 Oct 20262027年型ODS/HFCの割当額および初期振替書類の提出期限を決定 31 Oct 2026GB/T 18837-2026 マルチスプリット規格の有効性 1 Nov 2026欧州連合(EU)のF-Gas GWP<150独立型配置禁止措置 1 ヤン 2027F-ガスハンドラー認証の調和 11 Mar 2027三菱メヒツ、米国生産開始を狙った April 2027アトラス・コプコ–ユーロクリマトが標的に迫る Q3 2026ボッシュのホームコンフォート統合により、JCIユニットをターゲットとするエンド・バイ・エンドを統合2027.
政策与监管
- 中国 7/1 ODS 监管集群进入第六周施行。各级生态环境部门继续对冷库、物流及工业保温现场加压——现场 HCFC-141b 聚氨酯喷涂泡沫、XPS 泡沫 HCFC 发泡剂及特定 HCFC 溶剂禁限(自第27周起已详述的2025年相关公告)持续落地。迎峰度夏交付期,向 HFO/烃类替代与回收台账压力不减。第24周 MEE 2027 ODS/HFC 配额征求意见稿(含 HFC-245fa 跨品类调增上限上调)仍在意见期;企业须于 2026年10月31日 前完成2027年度配额及初次流转申请。
- EPA 技术转换再审议生效(7/27)满一周后,行业协会把中期供给矛盾说得更直白。ACCA 8/5 分析指出:商超/远程冷凝等临时 GWP 放宽(尤其至2032年的 1400 上限)以及住宅/轻商用存量 R-410A 安装截止日取消,并不改变 AIM 法案产消时间表——下一档仍是 2029 年相对基线约削减 70%。EPA 亦曾提示:若不采取进一步行动,2029 年起 HFC 需求可能超过配额。承包商与主机厂面对的是「近端为可部署性延期」与「远端工质更紧」的对冲。
- 大西洋对岸,英国执法声量不减。环境署 8/5 民事罚单清单对五家企业合计开出逾 £11.6 万——Celsius Hire(£48,519.10)、Krone Trailer UK(£48,000)、Emicon-UK(£13,205.70)、SL Services Southern(£3,300)、Parkair.UK(£3,000)——主因预充 HFC 的制冷/空调/热泵设备投放大不列颠市场时未按 F 气体条例第14(1)条计入配额。同日,ADL Air Conditioning 因无证从事相关活动被罚 £1,230。另有逾 50 名议员(8/7)致函 MCS 与 UKAS,要求尽快完成空空热泵产品/安装商认证认可,以便兑现锅炉升级计划(BUS)已立法、最高 £2,500 的 ATA 补贴——券发放仍被卡在认证链条。
市场与产业
- 欧洲自控与应用侧热管理需求仍坚。Carel Industries(8/6)公布 2026 上半年营收 €3.701 亿,同比 +20.9%——承接第31周 Trane 订货与 Bosch–JCI Home Comfort 交割后,低 GWP 制冷、热泵与数据中心冷却的主机/改造项目仍在喂养零部件与自控订单簿。
- 展会体量重置秋季日历。Chillventa 2026(报道 8/8)纽伦堡 10/13–15 已列出 1,095 家展商——高于 2024 年的 1,010 与 2018 年峰值 1,019——主办方 NürnbergMesse 新增 1 号馆后可用面积约 85,930 m²。距开展约两个月即刷新预订纪录,是 R290 单体式平台、CO₂ 零售机组与 A2L VRF 谁会在 2027年1月1日 欧盟 GWP<150 自容式投放规则前抢镜的领先指标。
- 项目与并购余波继续重画渠道地理。Lu-Ve(报道 8/6)向中国一座新建、单层高度约 62 m 的全自动冷库供应 28 台 CO₂ 冷风机——同类设施中属极高——凸显亚洲冷链高度与自然工质硬件。Atlas Copco 7 月中旬协议收购广东欧科(工业冷水/热泵;2025 营收约人民币 12.8 亿;目标 2026 年三季度 交割)仍是工业过程热泵整合焦点,对照 Bosch 将原 JCI Home Comfort 网络整合至 2027 年底的节奏。
标准与合规
- 中国家用太阳能热水能效标识进入第二周落地:FAS 2026/550 与 GB 26969-2025 自 8/1 施行;该日前出厂/进口库存可延迟至 2028年8月1日 加施标识。企业仍须并行管理 FAS 2025/45(热泵冷水等)与 2026/550(家电及太阳能热水)两套目录并按 SKU 留痕。GB/T 18837-2026《多联式空调(热泵)机组》仍指向 2026年11月1日 实施。
- 能力与测试产能从「软约束」走向「硬投资」。德累斯顿 ILK(8/8)扩展 R290 压缩机测试能力至约 48 m³/h 容积流量,直接回应赶在欧盟 2027年1月1日 GWP<150 自容式投放禁限(距今不足五个月)前放量的烃类单体式与商用热泵项目。同周英国 F 气体民事罚单再次说明:预充进口配额核算与从业人员认证,约束力不亚于热力学本身。IOR Skills Alliance 伦敦场次(2026年9月24日)与 2027年3月11日 从业人员认证统一时钟不变。
技术与示范
- 商用 VRF 在 R32 上继续上新,即使欧洲单体式正转向烃类。Clivet(8/3)推出 CVT9(CVT9-Y)R32 热泵室外机——单模块五档 25.2–45 kW,组合至 90 kW——配备 EasyCom 自由拓扑总线、对齐 IEC 60335-2-40 的截止阀箱与泄漏传感器(支撑小空间内机)、EVI 变频涡旋,SCOP 最高约 4.9 / SEER 最高约 8.6,并通过 Eurovent 认证。对接第31周 Samsung DVM S2 R32:商用 VRF 选择较低 GWP 的 HFC 平台,而欧盟自容式 ≤50 kW 规则把 2027 年的压力推给 R290。
- 自然工质硬件与现场试验填满应用栏。Lu-Ve 中国 62 m 级 CO₂ 冷库冷风机包(见市场栏)与 Trane 报道的自主太阳能冷藏集装箱现场试验(报道 8/6)相呼应——离网与韧性场景的另一条可部署叙事。研发台侧,德累斯顿 ILK 扩展的 R290 压缩机台架(见标准栏)与 Danfoss 面向 Chillventa 预告的 R290 涡旋/喷气增焓包及高温工业热泵螺杆(过程温度指向约 120 °C),勾勒主机厂将在纽伦堡展示的零部件栈。
接下来哪天
- 本周已完成:Clivet CVT9 R32 VRF 发布(8/3);ACCA 就 TT 后 AIM/2029 供给发声、英国环境署 F 气体配额民事罚单及 ADL 认证罚单(8/5);Carel 上半年业绩、Lu-Ve 中国 CO₂ 冷风机、Trane 自主太阳能冷藏试验(8/6);50+ 议员敦促空空热泵/BUS 认证(8/7);Chillventa 展商预订创纪录(1,095)与德累斯顿 ILK R290 测试扩容(8/8)。
- 前瞻:IOR Industry Skills Alliance 伦敦 2026年9月24日;Chillventa 2026 纽伦堡 2026年10月13–15日;MEE 2027 ODS/HFC 配额及初次流转申请截止 2026年10月31日;GB/T 18837-2026 多联机标准 2026年11月1日 实施;欧盟 GWP<150 自容式投放禁限 2027年1月1日;F 气体从业人员认证统一 2027年3月11日;三菱 MEHITS US 投产目标 2027年4月;Atlas Copco–欧科交割目标 2026年三季度;Bosch Home Comfort 整合 JCI 单元目标至 2027 年底。