本期要點
- R32 沒動,R22 少了一千 East China R32 is still ¥63,500–64,500/t. The R22 market price is ¥19,000–20,000/t, down ¥1,000 from the previous working day.
- 工廠報盤是另一張單 The morning note’s big-plant R32 offer is about ¥65,500/t. Meilan in Taixing, on 23 Oct, printed R32 at ¥64,500/t and R22 at ¥24,000/t.
- 80℃ 要看空氣溫度 Refra 市場負責人說,空氣 0℃ 時出水 80℃,空氣 −20℃ 時出水 75℃。訪談沒有附檢測報告。
- 450 kW 這臺還沒賣 Mirai 的 MT 450 HP 沒有公佈客戶,明年年中才賣。700 多份訂單是較小的那兩臺。
- 日本兩本標準沒看到書 The issue list has been in maintenance since 22 Oct. The 20 Oct announcement was three shoe-heel standards.
R32 沒動,R22 少了一千
East China R32 is still ¥63,500–64,500/t. The R22 market price is ¥19,000–20,000/t, down ¥1,000 from the previous working day.
隆众’s morning note at 08:56 on 21 Oct prints East China ex-factory reference prices. R32 is ¥63,500–64,500/t, mainstream ¥64,500, change 0. Refrigerant-grade R22 is ¥19,000–20,000/t, mainstream ¥19,000, down ¥1,000 from the previous working day. The East China note at 17:50 on 20 Oct still printed R22 at ¥20,000/t. The morning note says the change is a point price against the adjacent working day, not a daily average. The East China note at 16:18 on 21 Oct prints the same band.
The export table in that morning note is August and September. R32 exports are 2,559.814 t in August and 4,354.166 t in September, with average prices of $8,365.872/t and $8,041.375/t. R22 exports are 7,036.583 t and 8,081.814 t, with average prices of $2,309.830/t and $2,213.764/t. The arrows on the table are 隆众’s estimate for the next period. The note also says R32 plants are running near 40%, and spot supply is mostly on contract. The October hydrogen-fluoride tender, ¥14,500–14,800/t delivered, is a feedstock price.
工廠報盤是另一張單
The morning note’s big-plant R32 offer is about ¥65,500/t. Meilan in Taixing, on 23 Oct, printed R32 at ¥64,500/t and R22 at ¥24,000/t.
The same 21 Oct morning note puts the mainstream plants’ R32 ex-factory offer near ¥65,500/t, and prints the China-market offer and the export offer at that same level. At 08:38 on 23 Oct, Meilan in Taixing, Jiangsu, printed R32 at ¥64,500/t and R22 at ¥24,000/t, each unchanged from the previous working day. The ¥24,000 R22 and the market ¥19,000 are two sheets. The ¥65,500 plant offer and the ¥63,500–64,500 market band are two sheets as well. Juhua and Dongyue did not have a new quote opened this week. On 16 Oct, in week 42, Juhua’s R32 was ¥65,500/t and its R22 was ¥24,000/t; Dongyue Lüleng printed the same two figures. That was last Friday’s sheet.
80℃ 要看空氣溫度
Refra 市場負責人說,空氣 0℃ 時出水 80℃,空氣 −20℃ 時出水 75℃。訪談沒有附檢測報告。
The Natural Refrigerants interview of 22 Oct adds the air temperature that week 42 did not have. Ilona Pavšukova, Refra’s head of marketing, said the air-to-water R290 heat pump can hold 80°C water when the air is down to 0°C, and 75°C water when the air is down to −20°C. The unit has four independent circuits, heating capacity 30–400 kW, a 45 bar high side, Dorin compressors and Danfoss controls. In cascade she said 1–2 MW, and that the total depends on the site. Third-party safety certification to EN 378 is also her statement. The note has no test sheet.
The same interview describes the AirCooledCO2 Galaxy booster: 62–267 kW medium-temperature cooling, 8–59 kW low-temperature cooling, and custom builds up to 1 MW, with Bitzer compressors. The gas cooler, receiver and controls are in one package. Those are stand descriptions. To set a water temperature against a real site, write the air temperature, the supply temperature and the load on one sheet. The industrial heat-pump viability guide is the place to check those three. It does not turn an interview into a test report.
450 kW 這臺還沒賣
Mirai 的 MT 450 HP 沒有公佈客戶,明年年中才賣。700 多份訂單是較小的那兩臺。
The Natural Refrigerants note of 20 Oct, updated 21 Oct, names the machine MT 450 HP. Mirai has not announced a customer. Sale is the middle of next year. Hot water up to 73°C, ambient −20°C to 35°C, optional to 45°C, was already in week 42. The more than 700 orders for 2027 are still the smaller MT 290 and MT 350, at 290 kW and 350 kW. Sergey Kravtsov, director of business development, said the smaller machines did half a million starts and stops on a stress test with no performance degradation, and that load can run from 30% to 100%. He also said they cost a bit more than other R290 compressors. That is a booth interview. The test is on a test stand. ENGIE Refrigeration is developing a chiller platform on the Danfoss R600a Turbocor compressor for comfort cooling. The note says the platform is in development.
加州議會頁寫上了章程 738
Checked 25 Oct, the legislature page shows Chapter 738, dated 28 Sep. That is a residential permit statute. It is not a factory approval.
The California legislature status page, opened 25 Oct, shows SB 222 as chaptered. Chapter 738, Statutes of 2026, is dated 28 Sep. The governor approved it the same day. House location is Secretary of State. The page marks it inactive, chaptered, and non-urgency. In week 42 that page returned 403. On 11 Oct it still said enrolled, with no chapter number. The chapter date sits before this week. What changed this week is that the official page itself now shows the number. The statute covers residential heat-pump water heaters and residential heat-pump HVAC. A factory project does not take its permit from this chapter. A homeowners’ rule that blocks a resident from installing one of these heat pumps is written as void. That is still housing.
The working dates are in the chapter text opened the same day. From 1 Jul 2027, a city or county offers asynchronous inspection of these residential installations, so the contractor and the inspector do not have to stand there together. On or before 1 Jan 2028, a city or county may require up to one nondiscretionary permit for an installation it approves administratively. A panel change or structural work can have its own permit. A building official can require more than one permit with written findings of a specific health or safety impact and no feasible way around it. On or before 1 Jul 2028, qualifying swap-outs get an online permit in real time: no new panel, no structural work, and a like-for-like replacement. Smaller cities and counties have exceptions in the text. The permit-fee cap is $150 for a heat-pump water heater and $200 for heat-pump HVAC. Section 51297.57 writes the exception as a city under 5,000 people and a county under 150,000, including cities in that county. Another section in the same chapter uses “or”. Quote the chapter when using the exception. Third-party technology fees sit outside the cap. A city can still charge more after showing the reasonable cost. The status page says the bill is non-urgency. The default start of a non-urgency California statute is 1 Jan 2027. These dates come from the 28 Sep chapter. They were not written this week.
日本兩本標準沒看到書
The issue list has been in maintenance since 22 Oct. The 20 Oct announcement was three shoe-heel standards.
Week 42’s issue list put JIS B 8630, commercial refrigerators and freezers, and JIS S 2076, hybrid water-heater efficiency, on 20 Oct. Opened again on 25 Oct, that address is a maintenance notice: emergency maintenance from 16:00 on 22 Oct, end time not set. The JSA announcement of 20 Oct is three women’s shoe-heel standards, JIS S 5041, JIS S 5042-1 and JIS S 5042-2. The commercial-refrigerator standard and the hybrid water-heater standard stay unchecked. They are not written here as published.
接下來哪天
Nothing new took effect this week. Four headlines stay out of the stories: Tongling on 22 Oct reposted the 2 Sep production ban; the Wiesbaden store piece says the project was announced in May; the 53% heating figure is an older hypermarket model, and ACHR’s article is 16 Oct; the North American condensing-unit piece is 19 Oct, from a late-September conference, and 100–300 units is a 2027 sales expectation.
- 20 Oct 2026: JSA announced JIS S 5041, JIS S 5042-1 and JIS S 5042-2, three shoe-heel tests. The refrigeration issue list, opened 25 Oct, is the maintenance page that started at 16:00 on 22 Oct. JIS B 8630 and JIS S 2076 were not confirmed as published.
- 28 Oct 2026: UK Autumn Budget, carried from week 42. No new notice was opened this week.
- 31 Oct 2026: China 2027 ODS/HFC quota and initial-transfer applications, carried from week 42. No notice opened this week replaced that date.
- 1 Nov 2026: GB/T 18837-2026, multi-split air-conditioning (heat pump) units. The standards page opened 25 Oct still says not yet in force. Publication on that page is 30 Apr 2026. The effective date is 1 Nov 2026.
- 1 Jan 2027: EU GWP<150 limits for defined self-contained air conditioners and heat pumps up to 50 kW, with safety exceptions. China bans production of HCFC-22 multi-split air-conditioning (heat pump) units, from the MEE notice of 2 Sep 2026. SB 222’s default start, as a non-urgency statute, is the same day. The working dates in the chapter are later.
- 1 Jul 2027, 1 Jan 2028, 1 Jul 2028: the residential inspection, single-permit and online-permit dates in Chapter 738. The amounts and the exceptions are in the section above. The chapter date remains 28 Sep 2026.
- 19–25 Oct 2026 — European Union: no regulation taking effect this week was opened.
- No opening date: Canada’s heat-pump rebate portal still has no opening date in the week 42 record. No new notice was opened this week.
出處
- 隆众 — refrigerant morning note, 21 Oct 2026, 08:56
- Mysteel / 隆众 — East China refrigerant prices, 20 Oct 2026, 17:50
- Mysteel / 隆众 — East China refrigerant prices, 21 Oct 2026, 16:18
- Mysteel / 隆众 — Meilan refrigerant offers, Taixing, 23 Oct 2026
- Natural Refrigerants — Refra R290 heat pump, 22 Oct 2026
- Natural Refrigerants — Mirai Intex MT 450 HP, 20 Oct 2026, updated 21 Oct
- California Legislature — SB 222 status, opened 25 Oct 2026
- California SB 222, Chapter 738, chapter text opened 25 Oct 2026
- JSA — issue-list address, maintenance notice from 22 Oct 2026, opened 25 Oct
- JSA — shoe-heel standards JIS S 5041, S 5042-1 and S 5042-2, 20 Oct 2026
- China national standards — GB/T 18837-2026, opened 25 Oct 2026
- China MEE — ban on producing HCFC-22 multi-split air-conditioning (heat pump) units, 2 Sep 2026
- Tongling — repost of the same MEE notice, 22 Oct 2026
- Thermal Control Business Update — Wiesbaden CO₂ store, 23 Oct 2026, describing a May announcement
- ACHR News — Copeland and Henderson hypermarket model, 16 Oct 2026
- Natural Refrigerants — Hillphoenix and Hussmann CO₂ units, 19 Oct 2026
本期要点
- R32 没动,R22 少了一千 华东 R32 仍是 6.35–6.45 万元/吨。R22 市场价 1.9–2 万元/吨,比前一个工作日少一千。
- 工厂报盘是另一张单 早报里的大厂 R32 报盘约 6.55 万元/吨。泰兴梅兰 23 日的单是 R32 6.45 万、R22 2.4 万。
- 80℃ 要看空气温度 Refra 市场负责人说,空气 0℃ 时出水 80℃,空气 −20℃ 时出水 75℃。访谈没有附检测报告。
- 450 kW 这台还没卖 Mirai 的 MT 450 HP 没有公布客户,明年年中才卖。700 多份订单是较小的那两台。
- 日本两本标准没看到书 发行清单从 10月22日起在维护。10月20日公布的是三本女鞋鞋跟标准。
R32 没动,R22 少了一千
华东 R32 仍是 6.35–6.45 万元/吨。R22 市场价 1.9–2 万元/吨,比前一个工作日少一千。
隆众 10月21日 8:56 的早报给出华东出厂参考价。R32 是 6.35–6.45 万元/吨,主流价 6.45 万,涨跌为 0。制冷剂级 R22 是 1.9–2 万元/吨,主流价 1.9 万,比前一个工作日少 1000 元。10月20日 17:50 的华东行情里,R22 还是 2 万元/吨。早报写明,涨跌是相邻两个工作日的时点价,不是全天成交均价。10月21日 16:18 的华东行情仍是这个区间。
早报里的出口表是 8 月和 9 月。R32 出口量 2559.814 吨、4354.166 吨,均价 8365.872 美元/吨、8041.375 美元/吨。R22 出口量 7036.583 吨、8081.814 吨,均价 2309.830 美元/吨、2213.764 美元/吨。表上的箭头是隆众对下一期的估计。早报还写,R32 开工率维持在 四成附近,现货主要走合约。10 月氟化氢招标价 1.45–1.48 万元/吨送到,是原料价。
工厂报盘是另一张单
早报里的大厂 R32 报盘约 6.55 万元/吨。泰兴梅兰 23 日的单是 R32 6.45 万、R22 2.4 万。
同一篇 10月21日 早报把主流工厂的 R32 出厂报盘写在 6.55 万元/吨附近,并写内贸、外贸都报在这个价附近。10月23日 8:38,江苏泰兴梅兰的 R32 是 6.45 万元/吨,R22 是 2.4 万元/吨,都和上一工作日一样。2.4 万的 R22 和市场上的 1.9 万,是两张单。6.55 万的工厂报盘和 6.35–6.45 万的市场区间,也是两张单。巨化和东岳这周没有打开新报价。第42周 10月16日,巨化 R32 是 6.55 万、R22 是 2.4 万,东岳绿冷也是这两个数。那是上周五的单。
80℃ 要看空气温度
Refra 市场负责人说,空气 0℃ 时出水 80℃,空气 −20℃ 时出水 75℃。访谈没有附检测报告。
Natural Refrigerants 10月22日 的访谈,补上了第42周没有的空气温度。Refra 市场负责人 Ilona Pavšukova 说,这台空气源 R290 热泵在空气低到 0℃ 时可以维持出水 80℃,空气低到 −20℃ 时维持出水 75℃。机组有四套独立回路,制热 30–400 kW,高压侧 45 bar,用 Dorin 压缩机和 Danfoss 控制。复叠她说到 1–2 MW,并说总容量要看现场。按 EN 378 做的第三方安全认证,也是她说的。这篇没有附检测报告。
同一篇访谈写了 AirCooledCO2 Galaxy 增压机组:中温制冷 62–267 kW,低温 8–59 kW,定制可到 1 MW,压缩机是 Bitzer。气体冷却器、储液器和电控做在一套里。这些是展台介绍。拿水温去对现场时,把空气温度、出水温度和负荷写在同一张单上。工业热泵项目可行性指南 用来核对这三项。它不把访谈变成检测报告。
450 kW 这台还没卖
Mirai 的 MT 450 HP 没有公布客户,明年年中才卖。700 多份订单是较小的那两台。
Natural Refrigerants 10月20日 的稿、21日 更新,把这台机器写成 MT 450 HP。Mirai 还没有公布客户,销售时间是明年年中。出水至 73℃、环境温度 −20℃ 至 35℃、可选至 45℃,第42周已经写过。2027 年 700 多份订单仍是较小的 MT 290 和 MT 350,容量 290 kW 和 350 kW。业务发展负责人 Sergey Kravtsov 说,较小机型在试验台上做过 50 万次启停,没有性能衰减,负荷可以在 30% 到 100% 之间调。他还说,小机型比别的 R290 压缩机贵一点。这是展台访谈,试验在试验台上。ENGIE Refrigeration 正在开发用 Danfoss R600a Turbocor 压缩机的冷水机平台,面向舒适供冷。稿子写的是平台仍在开发。
加州议会页写上了章程 738
10月25日查看,议会页写着章程 738,日期是 9月28日。这是住宅许可规则,不是工厂项目的审批。
10月25日 打开的加州议会状态页,把 SB 222 标成已经成章。章程 738,2026 年制定法,日期是 9月28日。州长当天批准。法案所在位置是州务卿。页面标为已成章程、非紧急。第42周这页返回 403。10月11日 还标着已登记,没有章程号。章程日在本周之前。这周变的是:官方面页自己把章程号挂出来了。章程管的是住宅热泵热水器和住宅热泵暖通。工厂项目不按这一章去办许可。业主规约如果禁止住户安装这类热泵,章程把它写成无效。那仍是住宅。
工作时点写在同一天打开的章程文本里。2027年7月1日 起,市、县为这类住宅安装提供异步检查,承包商和检查员不必同时在场。2028年1月1日 前,市、县对行政批准的一次安装,最多可以要求一份非裁量许可。换配电盘或做结构工程,可以另开许可。建筑官员写出书面认定,说明对公共健康或安全有具体不利影响,而且没有可行的避开办法时,也可以要求多于一份。2028年7月1日 前,符合条件的替换安装要能在线实时出证:不换新配电盘、不做结构工程、并且是原位替换。人口较少的市、县在正文里有例外。许可费上限是热泵热水器 150 美元、热泵暖通 200 美元。第 51297.57 条把例外写成人口少于 5000 的市,和人口少于 15 万 的县(含该县里的市)。同一章另一条用的是「或」。引用豁免时对着章程原文。第三方技术服务费不在这个上限里。市、县拿出合理成本的证据后,仍可以收更高的许可费。状态页标为非紧急。非紧急加州制定法的默认生效日是 2027年1月1日。这些日期来自 9月28日 的章程,不是这周新写的。
日本两本标准没看到书
发行清单从 10月22日起在维护。10月20日公布的是三本女鞋鞋跟标准。
第42周的发行清单把 JIS B 8630(商用冰箱和冷冻柜)和 JIS S 2076(混合式热水器效率)排在 10月20日。10月25日 再打开那个地址,页面是维护通知:10月22日 16:00 起紧急维护,结束时间未定。日本规格协会 10月20日 的新闻稿公布的是三本女鞋鞋跟标准:JIS S 5041、JIS S 5042-1、JIS S 5042-2。商用冰箱和混合热水器这两本,这周没有核对到书,这里不写成已经出版。
接下来哪天
这周没有新法规生效。四则标题不进正文:铜陵 10月22日转发的是 9月2日的禁产公告;威斯巴登店的杂志稿写着 5月已经宣布;53% 是更早的大卖场模型,ACHR 的稿在 10月16日;北美冷凝机组的文章是 10月19日,会在 9月底,100–300 台是对 2027 年销量的预计。
- 2026年10月20日:日本规格协会公布 JIS S 5041、JIS S 5042-1、JIS S 5042-2,三本鞋跟试验。10月25日 打开的制冷相关发行清单,是 10月22日 16:00 开始的维护页。JIS B 8630 和 JIS S 2076 没有核对到已经出版。
- 2026年10月28日:英国秋季预算,沿用第42周。本周没有打开新的通知。
- 2026年10月31日:中国 2027 年 ODS/HFC 配额及初次流转申请截止,沿用第42周。本周没有一份通知改掉这个日期。
- 2026年11月1日:GB/T 18837-2026《多联式空调(热泵)机组》。10月25日 打开的标准页仍标为即将实施。该页发布日是 2026年4月30日,实施日是 2026年11月1日。
- 2027年1月1日:欧盟对特定不超过 50 kW 的自容式空调和热泵实施 GWP<150 限制,设有安全例外。中国禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组,依据是 2026年9月2日 的生态环境部公告。SB 222 作为非紧急制定法,默认同一天生效。章程里的工作时点在这之后。
- 2027年7月1日、2028年1月1日、2028年7月1日:章程 738 里的住宅异步检查、一份许可和在线许可。金额和例外见上面一节。章程日仍是 2026年9月28日。
- 2026年10月19–25日——欧盟:本周没有打开一份在这七天内生效的法规。
- 没有开放日:加拿大热泵补贴门户在第42周的记录里仍没有开放日。本周没有打开新的通知。
出处
- 隆众:制冷剂早报,2026年10月21日 8:56
- 我的钢铁网 / 隆众:华东制冷剂价格,2026年10月20日 17:50
- 我的钢铁网 / 隆众:华东制冷剂价格,2026年10月21日 16:18
- 我的钢铁网 / 隆众:泰兴梅兰制冷剂报盘,2026年10月23日
- Natural Refrigerants:Refra R290 热泵,2026年10月22日
- Natural Refrigerants:Mirai Intex MT 450 HP,2026年10月20日,21日更新
- 加州议会:SB 222 状态页,2026年10月25日打开
- 加州 SB 222 章程 738 文本,2026年10月25日打开
- 日本规格协会:发行清单地址,2026年10月22日起维护,10月25日打开
- 日本规格协会:女鞋鞋跟标准 JIS S 5041、S 5042-1、S 5042-2,2026年10月20日
- 中国国家标准:GB/T 18837-2026,2026年10月25日打开
- 中国生态环境部:禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组,2026年9月2日
- 铜陵:转发同一份生态环境部公告,2026年10月22日
- Thermal Control Business Update:威斯巴登二氧化碳店,2026年10月23日,正文写 5月已经宣布
- ACHR News:Copeland 与 Henderson 的大卖场模型,2026年10月16日
- Natural Refrigerants:Hillphoenix 与 Hussmann 二氧化碳机组,2026年10月19日