芬蘭 delfort Tervakoski:Turboden 12 MWth 熱泵加 MVR 制工藝蒸汽
Public sources (Turboden, 17 Feb 2026; IEA HPT demo card): a large heat pump plus mechanical vapor recompression at a delfort specialty-paper mill, reported at 12 MWth and about 20 t/h of superheated steam. Not independently metered here.
Run detailed calculation with this case一键代入详细计算
工程數據
- 案例類型
- 公開來源案例 — 數據來自公開報告、論文或廠商資料
- 數據狀態
- 公開來源案例
- 數據來源
- Turboden press release, 17 Feb 2026: https://www.turboden.com/company/media/press/press-releases/4947/turboden-successfully-starts-up-the-worlds-largest-steam-producing-heat-pump-setting-a-new-benchmark-for-industrial-decarbonization — IEA HPT demo card: https://heatpumpingtechnologies.org/content/uploads/sites/81/2026/01/demo35turbodenpapermill20251013.pdf — Owner, 18 Feb 2026: https://delfortgroup.com/wp-content/uploads/2026/02/delfort-is-converting-the-first-paper-prodution-site-to-run-entirely-on-fossile-free-energy.pdf?v=1771400275 — Turboden English case page: https://www.turboden.com/case-histories/5278/delfortgroup — Turboden Italian case page: https://www.turboden.com/it/case-history/5278/delfortgroup
- 審閱 / 日期
- Editorial (Open Thermal AI) · 2026-11-02
- 行業
- 造紙
- 熱源溫度
- 8–17°C
- 熱匯溫度
- 150–180°C
- 溫升
- ≈ 133 K
- 供熱/製冷負荷
- 12000 kW
- 架構
- 閉式大型熱泵(多級離心,異丁烷)串聯機械蒸汽再壓縮,不是單獨的開式水蒸氣循環
- 結果狀態
- Turboden announced full operation on 17 Feb 2026 and said startup COP was about 10% above the guaranteed value. The IEA card records about 2,000 test hours from July to October 2025. Vendor wording calls it the largest steam-producing heat pump built; this site does not audit that ranking.
- Key risk
- Design COP is about 2 at a very large temperature lift; the guaranteed COP itself is not published in the press note. CO₂ totals differ between the two sources.
- 原有系統
- 特種紙生產原依賴化石燃料蒸汽;現場有低溫工藝餘熱
- 製冷劑
- Isobutane (IEA HPT demo card); steam side is mechanical vapor recompression
- COP
- 2
- 年度節能 / 減排
- Two public figures, not reconciled here: Turboden cites about 19,000 t/a CO₂ avoided (calculated Scope 1); the IEA card cites about 15,000 t/a
- 預計回收期
- 所用來源未披露回收期
項目背景
The owner’s 18 February 2026 announcement identifies Tervakoski, Finland, as the mill and confirms commissioning of a heat pump and electrode boiler. The heat-pump/MVR package recovers paper-process waste heat for steam.
敘述性輸入
熱源:工藝餘熱,報道約 10–20°C。熱匯:過熱蒸汽,報道 3.4 bar(a)、150–180°C,約 12 MWth、約 20 t/h。熱泵側工質:異丁烷(IEA HPT 案例卡)。
熱泵方案
閉式異丁烷熱泵提升低溫熱量,機械蒸汽再壓縮再把蒸汽提到紙機已有的壓力等級。Turboden 稱兩臺設備在各運行階段協同,並裝在佔地有限的既有房間內。
COP 與節能
IEA HPT demo card: design COP about 2, installation year 2025, about 2,000 test hours (July–October 2025), estimated CO₂ savings about 15,000 t/a. Turboden press release (17 Feb 2026): unit fully operational, startup COP about 10% above the guaranteed value, calculated Scope 1 avoidance about 19,000 t/a. This site has not remeasured either figure.
投資回報要點
The owner reports over €50 million for the site’s energy transformation, including an electrode boiler. This is not the heat-pump purchase price; standalone heat-pump investment and payback remain undisclosed.
FAQ
這是獨立計量覈驗案例嗎?
No. Evidence level is public-source. Figures come from Turboden's 17 Feb 2026 press release and the IEA HPT demo card (demo35, dated in the file name 2025-10-13). This site did not meter the plant.
與本站肉類廠案例有何不同?
那兩條是作者現場調研的匿名氨熱泵制熱水。本條是點名的公開蒸汽項目:閉式熱泵加機械蒸汽再壓縮;來源數字不一致時並列保留。
What changed in the 2 November 2026 review?
Added the owner-confirmed mill location and investment boundary. Turboden’s English case page says January 2026 operation; its Italian page says February. Retain the February commissioning announcements without choosing an exact month from inconsistent versions. No newer annual measured COP was located.