中國太極涪陵製藥廠:東方電機蒸汽熱泵至 165°C
Dongfang Electric (3 Feb 2026 start-up): Dongfang Electric reports an 890 kW steam heat pump and booster at the Taiji Fuling pharmaceutical plant in Chongqing, China, lifting about 40°C waste heat to 165°C saturated steam at a stated COP of 2.7. Not independently metered here.
Run detailed calculation with this case一键代入详细计算
工程數據
- 案例類型
- 公開來源案例 — 數據來自公開報告、論文或廠商資料
- 數據狀態
- 公開來源案例
- 數據來源
- China Heat Pump trade note, 9 Feb 2026: http://www.52chpc.com/show.php?itemid=88919 — industry reprint: https://iicnet.cn/article/7553 — Dongfang Electric, 3 Feb 2026: https://dfem.dongfang.com/info/1240/4031.htm
- 審閱 / 日期
- Editorial (Open Thermal AI) · 2026-11-02
- 行業
- 製藥
- 熱源溫度
- 40°C
- 熱匯溫度
- 165°C
- 溫升
- ≈ 125 K
- 供熱/製冷負荷
- 890 kW
- 架構
- 高溫蒸汽熱泵加增壓機;報道電功率約 330 kW,額定製熱 890 kW
- 結果狀態
- Dongfang Electric’s own 3 February 2026 announcement confirms commissioning at Taiji Fuling and reports about 330 kW electrical input, 890 kW rated heat and measured COP 2.7. This is a supplier report, not this site’s independent audit.
- Key risk
- 簡訊未寫工質、蒸汽壓力和年運行小時。噸級蒸汽量不應理解成數兆瓦鍋爐替代。
- 原有系統
- 行業報道稱制藥蒸汽原先來自天然氣或燃煤鍋爐;可利用約 40°C 的低溫餘熱
- 製冷劑
- Not stated in the trade reports used here
- COP
- 2.7
- 年度節能 / 減排
- 所用報道未給出經計量的年節能量
- 預計回收期
- 所用報道未披露回收期
項目背景
東方電氣所屬東方電機公開了其高溫蒸汽熱泵在中國重慶涪陵太極製藥廠的一套投運記錄。本條只收錄該公開報道,不是作者現場調研。
敘述性輸入
熱源:餘熱約 40°C。熱匯:165°C 飽和蒸汽。行業報道寫額定製熱 890 kW,電功率約 330 kW。
熱泵方案
蒸汽熱泵與增壓機回收低溫餘熱,把飽和蒸汽送回製藥工序,替代該負荷上的鍋爐蒸汽。簡訊沒有增壓機佈置以外的更細流程。
COP 與節能
報道稱在大溫升、890 kW 額定工況下 COP 爲 2.7。本條不轉寫獨立電錶數據、運行小時或蒸汽質量流量。
投資回報要點
所用報道沒有投資與回收期。
FAQ
這是獨立計量覈驗案例嗎?
不是。現已補上供應商原始公告,但本站未到廠或進行計量。
890 kW 和 12 MWth 紙廠案例應怎麼對照?
兩者都是公開來源的工藝蒸汽條目,但負荷大約相差一個數量級。這套製藥裝置是噸級蒸汽機組,不是大型鍋爐替代。
What changed in the 2 November 2026 review?
補充早期行業報道背後的製造商原始來源。未找到後續該項目累計運行小時或全年計量節能;這屬於來源補全,不是新的投運里程碑。