菲利普莫里斯博洛尼亞:SPH 兩級熱泵向乾燥機供應 139°C 蒸汽
SPH / JOA demo card (installation year 2025): at Philip Morris Manufacturing & Technology Bologna, a two-stage heat pump turns dryer exhaust heat into saturated steam at 139°C and 2.5 bar(g). Rated duty is 650 kW. A FAT COP of 2.5 is source-reported, not remeasured here.
Run detailed calculation with this case一键代入详细计算
工程數據
- 案例類型
- 公開來源案例 — 數據來自公開報告、論文或廠商資料
- 數據狀態
- 公開來源案例
- 數據來源
- SPH / JOA demo card: https://spheat.de/neu/wp-content/uploads/2026/03/demo50sphjoaphilipmorris20251013.pdf — PMI, 17 Mar 2026: https://www.pmi.com/sustainability/case-studies-and-market-stories/philip-morris-manufacturing-technology-bologna-zero-carbon-technologies-italy
- 審閱 / 日期
- Editorial (Open Thermal AI) · 2026-11-02
- 行業
- 乾燥
- 熱源溫度
- 36–50°C
- 熱匯溫度
- 90–139°C
- 溫升
- ≈ 40 K
- 供熱/製冷負荷
- 650 kW
- 架構
- 兩級往復式熱泵(SPH),由 JOA 與乾燥機溼排風直接熱回收集成
- 結果狀態
- The card lists installation year 2025, about 5,000 h/a, and a COP of 2.5 measured during factory acceptance testing. That FAT figure is not a published multi-season site audit.
- Key risk
- COP 2.5 is a supplier-reported FAT value. The card’s 5,000 h/year is not evidence of cumulative site runtime. Do not merge the 650 kW dryer module with PMI’s separate Crespellano heat-pump/electric-boiler program or apply owner savings percentages to the whole Bologna operation.
- 原有系統
- 工業乾燥機有溼排風;工藝蒸汽原先由工廠鍋爐供應
- 製冷劑
- R515B and R1233zd (two stages)
- COP
- 2.5
- 年度節能 / 減排
- Demo card reports about 3.9 GWh/year heat and 1.7 kt/year CO₂ savings; annual measurement period is not established in this review.
- 預計回收期
- 未披露;案例卡的投資與費用節約留空
項目背景
菲利普莫里斯博洛尼亞製造與技術中心經 SPH 與 JOA 公開了一套乾燥熱回收裝置,自行產汽。本站行業標籤爲乾燥,便於與食品蒸煮和紙廠蒸汽分開篩選。
敘述性輸入
Source water 50°C → 36°C after exhaust recovery. Sink 90°C → 139°C saturated steam at 2.5 bar(g). Heating capacity 650 kW. Design operating time about 5,000 h/a.
熱泵方案
溼排風先直接回收,兩級熱泵再把剩餘熱量先抬到約 80°C,再到 139°C 蒸汽並送回乾燥機。壓縮機爲往復式。集成方是 JOA Air Solutions,熱泵供貨是 SPH。
COP 與節能
COP 2.5 is explicitly a factory-acceptance measurement on the card, at the design point above. Annual heat delivery is given as about 3.9 GWh and CO₂ savings as about 1.7 kt/a. Investment is blank. PMI’s 17 March 2026 account locates the steam-heat-pump application at Zola Predosa and reports 40–50% lower primary fossil-steam demand and recovery of 30% of exhaust water. These owner figures are not an independent annual audit.
投資回報要點
所用案例卡沒有公佈投資或回收期。
FAQ
這是獨立計量覈驗案例嗎?
不是。證據等級爲公開來源。供應商案例卡稱 COP 在出廠驗收時測得,這不等於獨立的現場審計。
爲什麼行業標籤是乾燥?
公開的用途是把蒸汽送回工業乾燥機。乾燥是本案例庫已有篩選項,與食品和一般製造分開。
What changed in the 2 November 2026 review?
補充業主針對具體廠區的說明,分別保留出廠測試、年參考時數和收益披露。用於新項目之前,仍須取得對應計量週期和系統邊界。