上海電氣奉賢:1.1 MW 熔鹽儲熱耦合高溫熱泵供汽
Shanghai Electric (acceptance 9 May 2025): a 1.1 MW / 10.8 MWh molten-salt store coupled to a high-temperature heat pump, supplying industrial steam at a factory in Fengxian, Shanghai. This is thermal storage plus a heat pump, not a process-steam heat pump of the closed-cycle plus MVR type. Not independently metered here.
Run detailed calculation with this case一键代入详细计算
工程數據
- 案例類型
- 公開來源案例 — 數據來自公開報告、論文或廠商資料
- 數據狀態
- 公開來源案例
- 數據來源
- Shanghai Electric central research institute note via China Energy Storage Network, 12 May 2025: https://www.escn.com.cn/news/show-2173094.html
- 審閱 / 日期
- Editorial (Open Thermal AI) · 2026-11-02
- 行業
- 工業製造
- 熱源溫度
- 未披露
- 熱匯溫度
- 未披露
- 溫升
- 不適用
- 供熱/製冷負荷
- 1100 kW
- 架構
- 單罐熔鹽儲熱耦合高溫熱泵,用於綠色供汽
- 結果狀態
- Shanghai Electric reported that after more than two months of trial operation the system passed the owner's acceptance on 9 May 2025 and entered commercial operation. Steam conditions are not published as one fixed pair.
- Key risk
- 高於 100% 的綜合效率是覈算口徑,不是蒸氣壓縮 COP。不要把本條歸入工藝蒸汽熱泵。
- 原有系統
- 奉賢工廠的工業蒸汽需求;公開系統以熔鹽罐儲熱並釋出蒸汽
- 製冷劑
- Not stated in the acceptance note used here
- COP
- 未披露
- 年度節能 / 減排
- 來源聲稱:噸蒸汽電耗約 743 kWh,比其所用對比低 12%;所述綜合效率 102% 在這裏不當作熱泵 COP
- 預計回收期
- 所用報道未披露回收期
項目背景
上海電氣中央研究院公開了位於中國上海奉賢某工廠的熔鹽與高溫熱泵供汽系統。案例庫標籤是儲熱出汽,因此與 delfort、武田等已投運工藝蒸汽熱泵分開。
敘述性輸入
已公佈額定值:1.1 MW、儲熱 10.8 MWh。所用報道沒有固定的蒸汽溫度和壓力。電耗寫爲約 743 kWh/噸蒸汽。
熱泵方案
單罐熔鹽儲熱與高溫熱泵耦合。研究院描述了靜態熔鹽換熱、協同控制和負荷跟隨。交付物是蒸汽;設備沒有被寫成閉式熱泵加機械蒸汽再壓縮。
COP 與節能
Acceptance is dated 9 May 2025 after a trial longer than two months. The 102% combined-efficiency figure and the 743 kWh/t claim are repeated only as source statements. No COP is shown on the card.
投資回報要點
所用報道沒有投資與回收期。
FAQ
這是獨立計量覈驗案例嗎?
不是。證據等級爲公開來源。驗收由上海電氣報道。本站未對該工廠計量。
爲什麼標籤是儲熱出汽,而不是工藝蒸汽熱泵?
公開架構是熔鹽罐耦合高溫熱泵。這與直接產工藝蒸汽的閉式熱泵(無論是否再串機械蒸汽再壓縮)不是同一條路線。
What changed in the 2 November 2026 review?
本次未找到可確認屬於該項目的更新計量運行報告。所引驗收報道未能通過檢索工具重新打開,因此 2025 年數字仍是有出處的歷史披露,不是新覈驗的 2026 年性能。用於項目決策前,應取得業主或供應商的現行報告。