Shanghai Electric Fengxian: 1.1 MW molten-salt storage coupled to a high-temperature heat pump for steam

Shanghai Electric (acceptance 9 May 2025): a 1.1 MW / 10.8 MWh molten-salt store coupled to a high-temperature heat pump, supplying industrial steam at a factory in Fengxian, Shanghai. This is thermal storage plus a heat pump, not a process-steam heat pump of the closed-cycle plus MVR type. Not independently metered here.

Run detailed calculation with this case

Engineering data

Case type
Public-source case — figures from published reports, papers, or vendor materials
Data status
Public-source case
Data source
Shanghai Electric central research institute note via China Energy Storage Network, 12 May 2025: https://www.escn.com.cn/news/show-2173094.html
Reviewer / date
Editorial (Open Thermal AI) · 2026-11-02
Industry
Manufacturing
Source temperature
Not disclosed
Sink temperature
Not disclosed
Temperature lift
Not applicable
Heating or cooling duty
1100 kW
Architecture
Single-tank molten-salt storage coupled to a high-temperature heat pump for green steam
Result status
Shanghai Electric reported that after more than two months of trial operation the system passed the owner's acceptance on 9 May 2025 and entered commercial operation. Steam conditions are not published as one fixed pair.
Key risk
A combined efficiency above 100% is an accounting claim, not a vapor-compression COP. Do not file this entry under process steam heat pumps.
Existing system
Industrial steam demand at the Fengxian factory; the published system charges a molten-salt tank and releases steam
Refrigerant
Not stated in the acceptance note used here
COP
Not disclosed
Annual energy / emissions savings
Source claim: about 743 kWh electricity per tonne of steam, described as 12% below the comparison they use; a stated combined efficiency of 102% is not treated here as a heat-pump COP
Estimated payback
Not disclosed in the note used here

Project background

The central research institute of Shanghai Electric published a molten-salt and high-temperature heat-pump steam system at a factory in Fengxian, Shanghai, China. The library tag is thermal storage, so it stays apart from operating process-steam heat pumps such as the delfort and Takeda entries.

Narrative inputs

Published ratings: 1.1 MW and 10.8 MWh of storage. Steam temperature and pressure are not fixed in the note used here. Electricity use is stated as about 743 kWh per tonne of steam.

Heat pump solution

A single-tank molten-salt store is coupled to a high-temperature heat pump. The institute describes static salt heat exchange, coordinated control, and load following. Steam is the delivered product; the machine is not described as a closed heat pump plus MVR.

COP & savings

Acceptance is dated 9 May 2025 after a trial longer than two months. The 102% combined-efficiency figure and the 743 kWh/t claim are repeated only as source statements. No COP is shown on the card.

Investment / ROI notes

Capital cost and payback are not in the note used here.

FAQ

Is this a verified measured project?

No. Evidence level is public-source. Acceptance was reported by Shanghai Electric. This site did not meter the factory.

Why is the tag thermal storage rather than process steam heat pump?

The published architecture is a molten-salt tank coupled to a high-temperature heat pump. That is a different route from a closed heat pump that makes process steam directly, with or without MVR.

What changed in the 2 November 2026 review?

No newer project-specific metered operating report was located in this review. The cited acceptance report could not be reopened with the research tool, so the 2025 claims remain attributed historical disclosures, not newly verified 2026 performance. Obtain a current owner or supplier report before a project decision.