項目中心 · 填寫參考

能源熱值與排放因子

只供填寫對照。不是溫室氣體清單、能源審計、碳覈查或採購依據。作決定前,請換成合同熱值、燃料化驗單,或與項目同年、同地區、同邊界的官方公佈因子。

A heat-pump screen needs a 低位熱值 and an 排放因子 to turn a fuel bill into heat and a carbon direction. This page shows published ranges and which field they match. It does not change this site’s screening defaults, and it does not upgrade a reference figure into a measured value.

1 · 先看邊界,再看數字

同一個燃料名稱,可能對應不同的熱值基準、氣體和系統邊界。這些差別會改變你準備粘貼的數字。

低位熱值與高位熱值

This site’s screening uses the lower heating value (LHV / net calorific value). A higher (gross) value counts the latent heat of water vapour and is larger. Natural gas also depends on the meter condition (0 °C, 15 °C, or 20 °C) and on local gas quality. It is not one global constant.

CO₂ 不是 CO₂e

IPCC defaults below are CO₂ only, stationary combustion, net calorific basis, assuming full oxidation. They omit CH₄ and N₂O, so they are not CO₂e. UK DESNZ factors are CO₂e for combustion only and exclude well-to-tank (upstream) emissions. A grid average is not a marginal factor.

中國是表中的一個市場

中國與美國、英國、日本、歐盟並列。本頁不編一個「歐盟電力因子」。某份出版物沒有給出賬單單位下的低位熱值時,格子會寫明並留空。

Screening defaults on this site are unchanged: natural gas 9.7 kWh/m³, fuel oil 11.5 kWh/kg, purchased steam 650 kWh/t. They remain assumptions. 9.7 sits inside the China gas reference range below. 11.5 is near fuel oil but is not a named grade. 650 is a steam-enthalpy assumption, not a fuel calorific value. The 9.87 kWh/m³ figure in heat-pump fundamentals is a worked example, not a contract value.

2 · 填到哪個字段

先對齊賬單單位,再抄格子。

字段 應填單位 可以抄什麼
現場燃料熱值 每採購單位的 kWh(m³、kg 或 t) 只抄已經是該單位的低位 / 淨熱值
電網排放因子 每 kWh 電的 kg CO₂e 抄電網因子,並在來源字段寫明是 CO₂ 還是 CO₂e、以及年份
基準能源排放因子 按賬單單位:天然氣每 m³、燃油每 kg、蒸汽每 t 因子必須是同一單位。IPCC 因子是每 TJ,不是每 m³
外購蒸汽 有效焓,kWh/t;若有排放,再填每 t 填合同焓。它不是燃料熱值,也不能把每 kWh 的區域熱力因子直接當成每噸

3 · 熱值

只供填寫對照。標了「÷ 3.6」或「換算」的 kWh,是從所引出版物做的算術,便於複覈,不是另一份官方表。

只供填寫對照。不是溫室氣體清單、能源審計、碳覈查或採購依據。作決定前,請換成合同熱值、燃料化驗單,或與項目同年、同地區、同邊界的官方公佈因子。

燃料 IPCC 2006 表 1.2,淨熱值 中國 GB/T 2589-2020 表 A.1,低位 英國 DESNZ 2026,淨熱值 Do not paste as LHV
天然氣 48.0 MJ/kg(46.5–50.4),即 13.33 kWh/kg。按千克,不是按 m³。 32 238–38 979 kJ/m³ → 8.96–10.83 kWh/m³(÷ 3.6)。表中未寫明計量溫度。 淨熱值 10.03 kWh/m³,由 2.02633 kg CO₂e/m³ ÷ 0.20199 kg CO₂e/kWh(淨熱值)換算。英國供應商的 kWh 通常按高位熱值。 United States: EIA MER Appendix A is gross. The Btu/ft³ figure is recalculated each year in Table A4. Japan: METI standard calorific values are gross (Excel, FY2023 revision, updated March 2026). EU: use the net CV on the national gas bill. No single EU value.
LPG 47.3 MJ/kg(44.8–52.2),即 13.14 kWh/kg。 50 242 kJ/kg → 13.96 kWh/kg(÷ 3.6)。 淨熱值 12.76 kWh/kg,由 2 939.36 kg CO₂e/t ÷ 0.23032 kg CO₂e/kWh(淨熱值)換算。 United States: propane 3.841 million Btu/barrel, gross (EIA Table A1). Japan: gross, see the METI Excel. Not an LHV in kg.
柴油(輕油) 汽油/柴油 43.0 MJ/kg(41.4–43.3),即 11.94 kWh/kg。 柴油 42 705 kJ/kg → 11.86 kWh/kg(÷ 3.6)。 100% 礦物柴油淨熱值 11.95 kWh/kg,由 3 203.91 kg CO₂e/t ÷ 0.26806 kg CO₂e/kWh(淨熱值)換算。 美國:硫含量不高於 15 ppm 的餾分油,5.770 百萬 Btu/桶,高位(EIA 附錄 A,GREET 2025)。日本:高位。
燃料油(殘渣油) 殘渣燃料油 40.4 MJ/kg(39.8–41.7),即 11.22 kWh/kg。 燃料油 41 868 kJ/kg → 11.63 kWh/kg(÷ 3.6)。 淨熱值 11.32 kWh/kg,由 3 228.89 kg CO₂e/t ÷ 0.28523 kg CO₂e/kWh(淨熱值)換算。 美國:殘渣燃料油 6.287 百萬 Btu/桶,高位(EIA 附錄 A)。日本:高位。它們都不是本站默認的 11.5 kWh/kg。
煤(各列等級不同) 其他煙煤 25.8 MJ/kg(19.9–30.5),即 7.17 kWh/kg。 原煤 20 934 kJ/kg → 5.82 kWh/kg(÷ 3.6)。與「其他煙煤」不是同一等級。 工業用煤淨熱值 7.06 kWh/kg,由 2 415.04 kg CO₂e/t ÷ 0.34223 kg CO₂e/kWh(淨熱值)換算。 美國:表 A5 是按年更新的高位熱值,不是單一煤階。日本:高位。不要把三列當成同一種煤。
木質生物質 木材/木材廢棄物 15.6 MJ/kg(7.90–31.0),默認值對應 4.33 kWh/kg。含水率會把它拉過整個區間。 表 A.1 沒有生物質行。請用實測收到基低位熱值。 沒有單一淨熱值。同一工作簿裏,顆粒、木片和薪柴的質量基準因子不同。不要粘貼一個木材數字。 EIA 指出未風乾木材的高位與低位可以相差 40% 以上。日本和歐盟在這裏沒有單一木材值。
外購蒸汽 不是燃料熱值。 表 A.2 熱力當量 0.03412 kgce/MJ 是能耗折算係數,不是蒸汽焓。 區域熱力按每 kWh 公佈,不是按每噸。見排放因子表。 按合同填寫有效焓(kWh/t)。本站默認 650 kWh/t 在你替換之前仍是假設。
電 1 kWh = 3.6 MJ. Not a fuel LHV. 表 A.2 電力當量 0.1229 kgce/kWh 是折標係數,不是排放因子。 用電網表,不用熱值。 電網因子在後面的表。氫和工業副產氣在這裏沒有單一參考值,請用現場數據。

China clause 8.3: use a measured value or the supplier’s figure first. Appendix A is a reference only when those are unavailable. 1 kgce = 29 307.6 kJ (GB/T 2589-2020, clause 8.2). UK “derived” cells divide two factors from the DESNZ 2026 flat file (revised July 2026); they are not a separately published calorific-value table. United States heat contents in MER Appendix A are gross.

4 · 燃燒排放因子

只供填寫對照。不要把 CO₂ 寫成 CO₂e,也不要用高位熱值去乘 IPCC 的淨熱值因子。

只供填寫對照。不是溫室氣體清單、能源審計、碳覈查或採購依據。作決定前,請換成合同熱值、燃料化驗單,或與項目同年、同地區、同邊界的官方公佈因子。

燃料 IPCC 2006 表 1.4,kg CO₂/TJ,淨熱值 中國 英國 DESNZ 2026,範圍 1 燃燒,kg CO₂e 美國、日本、歐盟
天然氣 56 100(54 300–58 300)。按 TJ,不是按 m³。 GB/T 2589-2020 has no CO₂ factor. Do not file the unit-check product below as a China inventory factor. 每 m³ 2.02633;每 kWh 淨熱值 0.20199;每 kWh 高位 0.18231。只含燃燒,不含上游。 United States: EPA GHG Emission Factors Hub, commonly gross (HHV) — open the current Hub; not transcribed here. Japan: current MOE calculation list, on the gross basis used in the energy statistics. EU: national inventory or the gas supplier’s factor. No single EU factor.
LPG 63 100(61 600–65 600)kg CO₂/TJ。 GB/T 2589-2020 沒有該因子。 每噸 2 939.36(每 kg 2.939);每 kWh 淨熱值 0.23032。 Same rule as natural gas: match HHV vs LHV before copying a US or Japan factor.
柴油(輕油) 汽油/柴油 74 100(72 600–74 800)kg CO₂/TJ。 GB/T 2589-2020 沒有該因子。 100% 礦物柴油:每噸 3 203.91(每 kg 3.204);每 kWh 淨熱值 0.26806。 不要把 IPCC 的每 TJ 因子直接填進每 kg 字段。
燃料油(殘渣油) 77 400(75 500–78 800)kg CO₂/TJ。 GB/T 2589-2020 沒有該因子。 每噸 3 228.89(每 kg 3.229);每 kWh 淨熱值 0.28523。 殘渣油和柴油是不同的行,不要共用一個因子。
煤(各列等級不同) 其他煙煤 94 600(89 500–99 700)kg CO₂/TJ。 No factor in GB/T 2589-2020. Raw-coal LHV above is not this coal. 工業用煤:每噸 2 415.04(每 kg 2.415);每 kWh 淨熱值 0.34223。 煙煤默認值不是褐煤或原煤因子。
木質生物質 112 000 (95 000–132 000) kg CO₂/TJ. Biomass CO₂ is an information item, not part of national fossil totals. 表 A.1 沒有這一行,這裏也不給因子。 Scope 1 (CH₄ and N₂O only) 0.01193 per kWh for logs, chips, and pellets. Biogenic CO₂ is outside that total: 0.35 per kWh. Per tonne, biogenic CO₂ is 1 436.23 (logs), 1 335.71 (chips), 1 677.18 (pellets). Do not add the two layers unless the boundary says so. Do not treat wood CO₂ as a fossil-fuel reduction credit without a stated biogenic boundary.
外購蒸汽 取決於鍋爐燃料。沒有通用因子。 這些來源裏沒有通用的每噸排放因子。 區域熱力與蒸汽:0.17529 kg CO₂e/kWh(範圍 2)。5% 分配損失行另有每 kWh 0.00945。它們按熱的 kWh,不是按噸。 每噸排放 = 每 kWh 因子 × 你的焓(kWh/t)。用 650 kWh/t 乘英國的 0.17529,約得 114 kg CO₂e/t——這只是單位演示,不是可歸檔因子。

IPCC 表 1.4 假定氧化率爲 100%。英國因子不含上游井口到油箱排放,那些在同一工作簿的單獨行裏。歐盟沒有一個可以粘貼的單一燃燒因子。

5 · 電網電力

字段要的是 kg CO₂e/kWh。不少官方因子只是 CO₂,或把發電與網損分開。數字旁邊要記下氣體和邊界。

只供填寫對照。不是溫室氣體清單、能源審計、碳覈查或採購依據。作決定前,請換成合同熱值、燃料化驗單,或與項目同年、同地區、同邊界的官方公佈因子。

電網 公佈值 氣體與邊界
中國全國平均,2023 年 0.5306 kg CO₂/kWh 是 CO₂,不是 CO₂e。生態環境部、國家統計局公告 2025 年第 47 號。同一附件還有:不包括市場化交易非化石能源電量 0.6096;化石能源電力 0.8273。
中國區域電網,2023 年 華北 0.6361;東北 0.5122;華東 0.5500;華中 0.5271;西北 0.5543;南方 0.4042;西南 0.2472 kg CO₂/kWh 同一公告表 2。省級因子在該附件中,這裏不逐省列出。是 CO₂,不是 CO₂e。
美國 eGRID2023 第 2 次修訂 767.2 lb CO₂/MWh → 0.348 kg CO₂/kWh。CO₂e 列 770.9 lb/MWh → 0.3497 kg CO₂e/kWh。 U.S. total output rate, data year 2023, revision released 12 June 2025. Not a subregion and not a marginal rate. The kg figure is lb/MWh × 0.45359237 ÷ 1000. Use the project’s eGRID subregion when you have it.
英國 DESNZ 2026 發電 0.13096 kg CO₂e/kWh(範圍 2)。輸配 0.01299 kg CO₂e/kWh(範圍 3)。 英國屬地平均。除非邊界包含網損,不要把兩項相加。本頁不給一個混合後的「英國因子」。
歐盟 沒有單一因子。 用電錶所在國的國家清單,或 AIB 歐洲殘餘電力組合。殘餘組合不是屬地電網平均。
日本 沒有單一的全國粘貼值。 環境省與經濟產業省按電力事業者公佈算定·報告·公表制度的係數。請用賬單上的事業者和年份。

同一出版物已經分了區域電網時,全國平均就是錯的數。邊際因子和市場基準因子不在本表。

6 · 單位覈對:m³ → kWh → kg CO₂

下面只演示算術。乘積來自兩份出版物,不是可歸檔的因子。

  • 取中國參考區間上端 38 979 kJ/m³(GB/T 2589-2020 表 A.1)。
  • 38 979 ÷ 3 600 = 10.83 kWh/m³。同一區間下端 32 238 kJ/m³ 爲 8.96 kWh/m³。
  • 若再乘 IPCC 天然氣因子 56 100 kg CO₂/TJ(即 56.1 kg CO₂/GJ):0.038979 GJ/m³ × 56.1 = 2.19 kg CO₂/m³。區間下端用同一 IPCC 因子得到 1.81 kg CO₂/m³。
  • The UK 2026 combustion factor is a different number, 2.02633 kg CO₂e/m³, because the gas, the calorific value, and the gases included (CO₂e, not CO₂ only) are different. Do not average these.

本站初篩默認 9.7 kWh/m³ 落在 8.96 與 10.83 之間,它仍是假設。熱泵基礎裏的 9.87 kWh/m³ 是同一量級的教材例題,不是合同熱值。

7 · 下一步

  • 燃氣合同或燃料化驗單已經給出低位熱值時,用那個數,不用本表。
  • 沒有現場數字時,可以把對應列裏的低位 / 淨熱值當作初篩輸入,並在排放因子來源字段寫上出版物、年份和基準。
  • 若公佈值只是高位、按桶、按 TJ,或煤種不同,就保留初篩默認值並寫明。不要爲了把格子填滿而另做換算。
  • 電力優先用電錶所在的區域或事業者因子,並記下填的是 CO₂ 還是 CO₂e。
  • Which carbon the screen counts is drawn on the carbon-footprint picture guide.

Open 創建項目, return to heat-pump fundamentals (gas–electric price ratio), or the knowledge hub.

快速覈對

可以把 0.5306 填進電網字段嗎?

只有在使用中國 2023 年全國平均,並且寫明它是 kg CO₂/kWh、不是 CO₂e、來自公告 2025 年第 47 號時可以。項目若在該附件的某一區域電網,改用區域數字。

爲什麼英國天然氣按高位熱值的每 kWh 因子更小?

同一份排放被分到更大的高位熱值上。英國供應商的 kWh 通常按高位。把淨熱值因子用在高位 kWh 賬單上,會把排放算小。按 m³ 的因子可以避開這個選擇。

本頁會替換計算器裏的默認值嗎?

不會。在你填入現場值之前,天然氣仍是 9.7 kWh/m³,燃油仍是 11.5 kWh/kg,外購蒸汽仍是 650 kWh/t。本頁不會替你寫入這些字段。

本頁數字於 2026-10-07 從來源條所列出版物轉錄。它們是初篩填寫參考,不是清單、審計、覈查或採購依據。