US · Campbell Soup Dixon: steam-turbine-driven vapour recompression
A UC Davis site assessment published in 2013 documents steam turbines driving vapour compressors for tomato-paste evaporation.
Run detailed calculation with this case一键代入详细计算
Engineering data
- Case type
- Public-source case — figures from published reports, papers, or vendor materials
- Data status
- Public-source case
- Data source
- UC Davis CIFAR, Campbell Soup Steam System Assessment, March 2013, Table 1 and Steam Turbine Integration, pp. 16–17: https://cifar.ucdavis.edu/sites/g/files/dgvnsk1826/files/inline-files/Campbell_Soup_Steam_System_Assessment_final.pdf
- Reviewer / date
- Editorial (Open Thermal AI) · 2026-11-21
- Industry
- Food
- Source temperature
- Not disclosed
- Sink temperature
- Not disclosed
- Temperature lift
- Not applicable
- Heating or cooling duty
- Not disclosed
- Architecture
- Steam turbines supply shaft work to the vapour compressors in an open-cycle MVR system.
- Result status
- The assessment’s equipment inventory lists two MVR compressor drives of 1,375 and 380 hp. These figures describe shaft-drive ratings.
- Key risk
- The drive ratings describe shaft power. The 2013 assessment describes the equipment then installed and does not establish current configuration or isolated MVR savings.
- Existing system
- The tomato-processing plant used boiler steam, multi-effect evaporators and two mechanical vapour recompression (MVR) systems at the time of the assessment.
- Refrigerant
- R718
- COP
- Not disclosed
- Annual energy / emissions savings
- Not established in the sources reviewed.
- Estimated payback
- Not established in the sources reviewed.
Project background
The UC Davis assessment for the California Energy Commission treats vapour recompression as part of the factory’s steam system and includes an inventory of installed steam turbines.
Narrative inputs
Measure turbine steam flow and inlet and exhaust states, compressor vapour flow and pressure, evaporated water and auxiliary power. Check whether exhaust heat displaces other steam use.
Heat pump solution
The turbine expands drive steam to turn the compressor. The compressor raises the pressure and temperature of the process vapour so it can heat the evaporator.
COP & savings
Compare steam and auxiliary electricity per tonne of water removed. At the plant boundary, include boiler fuel or purchased steam and account for any useful turbine exhaust once.
Investment / ROI notes
Build a seasonal comparison using the current evaporator configuration, steam cost, auxiliary power, turbine maintenance and any alternative use for the drive steam.