Skyven Arcturus demonstration center, Texas: 1 MWth steam-generating heat pump

Skyven reported sustained COP 8.0 at its 1 MWth Texas steam-heat-pump demonstration center on 2 September 2026, up from 6.5 at commissioning. This is a supplier disclosure; the announcement does not give the demo temperature pair or measurement boundary.

Run detailed calculation with this case

Engineering data

Case type
Public-source case — figures from published reports, papers, or vendor materials
Data status
Public-source case
Reviewer / date
Editorial (Open Thermal AI) · 2026-11-02
Industry
Manufacturing
Source temperature
Not disclosed
Sink temperature
Not disclosed
Temperature lift
Not applicable
Heating or cooling duty
1000 kW
Architecture
Arcturus water-based steam heat pump; manufacturer describes vacuum flashing followed by multistage steam compression
Result status
The September 2026 announcement replaces the earlier roadmap with a supplier-reported result of 8.0. The numeric COP field remains blank because comparable test conditions are missing.
Key risk
Neither the source/steam temperature pair, test duration nor auxiliary-power boundary accompanies the new COP claim. Product-range limits do not establish the demo operating point; do not compare 8.0 directly with large-lift projects.
Existing system
Demonstration center for boiler-quality steam, not a published customer process line
Refrigerant
Water (manufacturer product description; demo conditions not disclosed)
COP
Not disclosed
Annual energy / emissions savings
Not stated as a measured annual total for this demonstration center
Estimated payback
Not disclosed

Project background

In November 2025 Skyven Technologies announced the Arcturus demonstration center in Farmers Branch, near Dallas, Texas. pv magazine described the same 1 MWth unit. A separate 2024 note said an Arcturus system would be supplied to an ethanol plant in Medina, New York; that host plant is not documented as operating in the sources used here, so this entry covers only the Texas demonstration center.

Narrative inputs

The demonstration unit is rated at 1 MWth. Its source temperature, steam pressure, operating hours and full metering boundary remain undisclosed in the releases reviewed.

Heat pump solution

The manufacturer describes waste heat heating water, vacuum flashing, and multistage steam compression. This describes the product architecture, not verified operating conditions of the demonstration unit.

COP & savings

Supplier-reported sustained COP rose from 6.5 at commissioning to 8.0 in the 2 September 2026 release. Controls, design and integration refinements are cited. No independent test report or seasonal result was located in this review.

Investment / ROI notes

No demonstration-project investment or verified payback is disclosed. Product performance ranges are not operating results for a customer factory.

FAQ

Is this a verified measured project?

No. This remains a public-source supplier demonstration. The updated COP claim lacks the conditions needed for direct project comparison.

Why keep a demonstration center in the case library?

It is a named, commissioned megawatt-class steam heat pump with a public date and a public capacity. The page states that it is not a customer factory and that the COP cannot be compared with large-lift plants until temperatures are published.