政策與監管
- China’s compliance shelf did not move this week. The 31 October deadline for 2027 ODS and HFC quota and initial-transfer applications is unchanged, and the 2027 draft freeze of HFC production and use totals at 2026 levels stays provisional until a final notice. MEE announcement 2026 No. 42 still bans production of HCFC-22 multi-split air-conditioning (heat pump) units from 1 January 2027, with product scope tied to the annex and to GB/T 18837-2026, which takes effect on 1 November. JB/T 15555-2026 remains in force from 1 September. A scan of late-September national announcements did not turn up a new refrigeration or heat-pump product standard. On price, ChemPriceHub’s 22–23 Sep print kept East China R32 flat: mainstream plants quoted about ¥65,500/t on coordinated China and export offers, the market band was ¥63,500–64,500/t, and the industry operating rate was near 40% under volume control. That is the same freeze-plus-tight-spot colour as week 38, not a new cut.
- In the English-speaking jurisdictions, the new document is British and the hard clock is still Californian. DESNZ published the UK Space Cooling Market Landscape Update on 24 Sep. The report, drawn from interviews between November 2024 and February 2025, lists air-to-air heat pumps as not fully recognised: MCS standards and tools were being updated at the time of drafting, and the Boiler Upgrade Scheme does not include air-to-air. A consultation on adding air-to-air to BUS had already closed when the report was drafted. The same barrier list names uncertainty over a GB F-gas update and over PFAS, comfort cooling that building regulations do not fully credit, too few F-gas-accredited installers, and install-and-run cost. The report also restates the GB/NI rule that single-split systems with less than 3 kg of refrigerant need a GWP below 750 from 2025—a looser shelf than the EU’s 1 January 2027 GWP<150 limit for defined self-contained air-conditioning and heat pumps up to 50 kW, which the Commission’s alternatives page still shows, including the band above 12 kW and up to 50 kW, with a safety exception to GWP 750. California SB 222 remains enrolled and at the Governor; the last recorded action is still presentation on 30 Aug, and the sign-or-veto deadline is 30 Sep.
市場與產業
- The DESNZ landscape is an installed-base count of fixed air conditioning, and it should sit beside—not be averaged with—week 37’s MCS retrofit tally or week 38’s AHRI July factory shipments. For 2024, the report estimates residential sales of about 9,000 single-splits, 1,000 multi-splits and 2,000 VRF condensing units, and an installed base of about 64,000 single-splits, 7,000 multi-splits and 15,000 VRF units. Counting one split per home, that is about 0.24% of UK homes; the authors flag the one-unit-per-home assumption as a simplification. Separately, about 2–3% of homes are estimated to have some cooling, mostly portable units, which are outside the study; stakeholders put portable sales near 50,000 a year. Non-residential 2024 sales are estimated at about 175,000 single-splits, 19,000 multi-splits, 18,000 VRF and 2,500 chillers, against an installed base of about 2.6 million single-splits, 143,000 multi-splits, 306,000 VRF and 48,000 chillers. Hydronic heat pumps are named and then excluded from the stock tables. The policy point that follows is the one week 38 already framed as a fiscal ask: if air-to-air stays outside BUS while electricity remains the expensive fuel, the reversible split will stay a specification outlier next to the water-based retrofit channel.
- On the European project side, Cooling Post (23 Sep) reported a commissioned cogeneration upgrade at Sauze d’Oulx in Piedmont. Meco Sauze, with Ecotermica Servizi, fitted one Trane XStream RTWF 125 HE heat pump to each of three cogeneration engines of 1,334 kW electrical. The units are said to lift intercooler heat from about 30°C to about 80°C for the district-heating network, and they can run on electricity generated on site. The project is described as fully commissioned, with a return on investment expected in less than two years. Treat the temperatures and the payback as project claims until the heat-pump boundary, the share of heat actually recovered, and the tariff are on the measurement sheet.
技術與示範
- Trane’s 20 TruComfort is a heating-weighted residential package, and the capacity-retention figures are not one number for every size. pv magazine (25 Sep) reports nominal ratings of 26,200 Btu/h cooling and 33,200 Btu/h heating on the 3-ton unit, 36,000 / 45,000 on the 4-ton, and two 5-ton variants at 48,500 / 55,000 and 48,000 / 55,500. Laboratory heating retention versus rated capacity is 107% / 85% at −15°C / −29°C for the 3-ton, 100% / 67% for the 4-ton, 87% / 53% for one 5-ton and 100% / 70% for the other. Trane has not published COP, HSPF2 or SEER2. The product is tied to the US Department of Energy Residential Cold Climate Heat Pump Challenge: an early prototype was tested at Oak Ridge National Laboratory in 2022, and nine field units in Minnesota, Montana, New York, Pennsylvania, Wisconsin and Texas accumulated more than 36,900 hours, including more than 18,300 in heating. In a January 2026 cold spell, Trane says one 5-ton unit in La Crosse, Wisconsin, held setpoint without supplemental heat down to −29°C; another held setpoint without backup to about −23°C, then used supplemental heat while the heat pump kept running. Configurations are an all-electric air handler or dual fuel with a furnace. Until a rating standard and the exact size are on the submittal, keep the 85% figure attached to the 3-ton laboratory case.
- Carrier’s WeatherFlex 50FC is the commercial rooftop answer to the same 1 January 2027 self-contained shelf, in the capacity band the EU page sets above 12 kW and up to 50 kW. The unit is air-to-air, uses variable-speed scroll compressors, and is offered for new build and retrofit with free cooling, heat recovery and variable ventilation. R-454C is listed on the Commission alternatives page at GWP 146 (GWP20 580, safety group A2L), which sits under the GWP 150 limit and above the safety-exception ceiling only if a site cannot use anything below 150. Carrier already sells a 50FC range on R-454B (GWP 465 on the same page) at about 22–90 kW, with published SEER 4.49–5.07 and SCOP about 3.45–3.80. Those seasonal figures were not repeated for the new R-454C series. Specify the refrigerant, the GWP band and the missing seasonal rating as three separate lines.
- Two smaller items belong in the screening file rather than a bill of quantities. Cooling Post (21 Sep) reports the HKUST elastocaloric device—TiNiCuCo, a double-layer fin refrigerant, a claimed 50% cut in component count and a drop in ineffective mass from 15% 至 5%—holding 400 W and 41 K across 1 million cycles. Accelerated tests are said to show no functional degradation after 100 million cycles, and the team expects more than a decade in real cooling duty while it develops an air conditioner. That is a materials-and-device result, not a catalogue COP. Separately, Danfoss (22 Sep) introduced the AK-GC52 controller for gas-cooler and receiver pressure in transcritical and subcritical CO₂ systems, including heat pumps and heat recovery, paired with ICMTS valves and ICAD actuators. No system COP is stated. No new Chinese product standard took effect this week; JB/T 15555-2026 is already in force, and GB/T 18837-2026 is still the 1 November event.
影響判斷
- For UK specification: the new stock count and the week-37 retrofit count describe different machines. Fixed single-splits and multi-splits sit in about 0.24% of homes; MCS-certified hydronic retrofits were the series that fell 22% in H1. Air-to-air is the technology the DESNZ barrier list says BUS omits, while MCS was still writing it into its standards during the interview window. The Autumn Budget question from week 38—whether levies move off electricity—now sits next to a second question: whether air-to-air is recognised as a heating product at all before reversible splits are asked to carry summer comfort.
- For refrigerant strategy: China’s signal is still a flat price under the freeze, with the operating rate near 40%. The low-GWP product news this week is A2L, split by market. Trane’s northern-US residential unit is R-454B (GWP 465). Carrier’s European rooftop is R-454C (GWP 146), sized for the self-contained band that hits GWP<150 on 1 January 2027. The elastocaloric result does not substitute for either refrigerant choice on a 2027 tender.
- For project owners: three days to the SB 222 deadline (30 Sep), a little over two weeks to Chillventa (13–15 Oct), then 1 November for GB/T 18837-2026, 31 October for China’s 2027 quota filing, and 1 January 2027 for both the EU self-contained GWP<150 limits and China’s HCFC-22 multi-split production ban. Treat Trane’s capacity-retention table, Carrier’s unpublished seasonal rating, the Sauze d’Oulx 30°C-to-80°C lift, and the HKUST 400 W / 41 K result as screening inputs. Require the size, the test standard, the refrigerant and the measurement boundary before any of them enters a financial model.
- Apply the signal: the week’s headline performance is heating capacity held at −29°C, without a published COP or HSPF2. A brochure retention rate still needs the test boundary. The extreme-testing note sets out why a claimed temperature point is not yet a verified duty.
接下來哪天
- 24 Sep 2026: IOR Industry Skills Alliance, London (passed; no public decision note by 27 Sep). 30 Sep: California Governor’s deadline to sign or veto SB 222 (three days). 13–15 Oct: Chillventa, Nuremberg (a little over two weeks). 28 Oct: UK Autumn Budget. 31 Oct: China 2027 ODS/HFC quota and initial-transfer applications. 1 Nov: GB/T 18837-2026 for multi-split air-conditioning (heat pump) units takes effect.
- 1 Jan 2027: EU GWP<150 limits begin for defined self-contained AC/heat-pump categories up to 50 kW, including the band above 12 kW, subject to safety exceptions; China bans production of HCFC-22 multi-split air-conditioning (heat pump) units. H1 2027: SLB targets close of the Kelvion acquisition (week 36). 30 Apr / 31 Aug 2027: planned China in-year HFC quota-adjustment windows under the 2027 drafts.
出處
- pv magazine — Trane cold-climate heat pump to −29°C, 25 Sep 2026
- pv magazine USA — Carrier WeatherFlex 50FC rooftop heat pump, 23 Sep 2026
- UK DESNZ — UK space cooling market landscape update, 24 Sep 2026
- UK DESNZ — landscape report PDF
- Cooling Post — elastocaloric cooling device, 21 Sep 2026
- Cooling Post — Sauze d’Oulx cogeneration heat-pump upgrade, 23 Sep 2026
- Cooling Post — Danfoss AK-GC52 CO₂ controller, 22 Sep 2026
- ChemPriceHub — East China R32, 22–23 Sep 2026
- California Legislature — SB 222 bill status
- European Commission — F-gas alternatives for air conditioning and heat pumps
- China MEE — ban on producing HCFC-22 multi-split air-conditioning (heat pump) units, 2 Sep 2026
政策与监管
- 中国履约货架本周没有挪动。10月31日 提交 2027 年度 ODS 与 HFC 配额及初次流转申请的期限未变;2027 年草案把 HFC 产消总量冻结在 2026 年水平,正式通知印发前仍按暂定处理。生态环境部 2026 年第 42 号 公告仍规定自 2027年1月1日 起禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组,产品范围由该公告附件及将于 11月1日 实施的 GB/T 18837-2026 界定。JB/T 15555-2026 自 9月1日 起仍有效。检索 9 月下旬的国家标准公告,未见新的制冷或热泵产品标准。价格方面,ChemPriceHub 9月22–23日 的记录显示华东 R32 持平:主流工厂内外贸协同报盘约 6.55 万元/吨,市场区间 6.35–6.45 万元/吨,行业开工率在控量保价下接近 40%。这仍是第38周那种「总量冻结加现货偏紧」的交易台口径,不是新的一档削减。
- 英语法域里,本周的新文件在英国,硬时钟仍在加州。DESNZ 于 9月24日 发布《英国空间制冷市场图景更新》。报告依据 2024年11月至2025年2月 的访谈,把空气-空气热泵列为尚未被充分承认:起草时 MCS 标准与工具正在更新,锅炉升级计划(BUS)不包含空气-空气。把空气-空气纳入 BUS 的咨询在报告起草时已经结束。同一份障碍清单还写到英国 F-gas 更新与 PFAS 的不确定性、建筑规范未充分计入舒适制冷、持有 F-gas 资质的安装工不足,以及安装与运行成本。报告同时重申:英国(含北爱尔兰)对充注不足 3 kg 的单分体,自 2025 年起要求 GWP 低于 750——这比欧盟自 2027年1月1日 起对特定不超过 50 kW 自容式空调与热泵实施的 GWP<150 限制更宽。欧盟委员会替代工质页仍列着该限制,其中包括 12 kW 以上至 50 kW 一档,并设安全例外可放宽到 GWP 750。加州 SB 222 仍为已登记、位于州长处;最近一条记录仍是 8月30日 呈送,签署或否决期限为 9月30日。
市场与产业
- DESNZ 这份图景统计的是固定式空调的保有量,应与第37周的 MCS 改造装机、第38周的 AHRI 7 月工厂出货并列,而不是平均成一个需求数字。报告估计 2024 年住宅销量约单分体 9,000 台、多分体 1,000 台、VRF 室外机 2,000 台,保有量约单分体 6.4 万台、多分体 7,000 台、VRF 1.5 万台。按一户一套分体折算,约占英国住宅的 0.24%;作者标明「一户一套」是简化。另有估计称约 2–3% 的住宅拥有某种制冷,其中大部分是便携机,不在本研究范围内;受访者把便携机年销量放在约 5 万台。非住宅 2024 年销量估计约单分体 17.5 万台、多分体 1.9 万台、VRF 1.8 万台、冷水机组 2,500 台,保有量约单分体 260 万台、多分体 14.3 万台、VRF 30.6 万台、冷水机组 4.8 万台。空气-水热泵被点名后排除在存量附表之外。由此接上的政策问题,正是第38周已经写成财政诉求的那一条:若空气-空气仍在 BUS 之外、电仍是贵的燃料,可逆分体就会继续站在空水改造渠道旁边,作为一种规范上的例外。
- 欧洲项目侧,Cooling Post(9月23日)报道皮埃蒙特大区 Sauze d’Oulx 一座热电联产改造已经投运。Meco Sauze 与 Ecotermica Servizi 合作,为三台电功率各 1,334 kW 的热电联产发动机各配一台 Trane XStream RTWF 125 HE 热泵。机组据称把中冷器热量从约 30℃ 升到约 80℃ 送入区域供热,并可用现场发电驱动。项目被描述为已完成调试,投资回收期预计短于 两年。温度与回收期在热泵边界、实际回收热量占比和热价写入测量表之前,应按项目口径处理。
技术与示范
- Trane 的 20 TruComfort 是偏制热的住宅方案,能力保持率并不是所有冷吨档共用一个数字。pv magazine(9月25日)报道,3 冷吨名义制冷 26,200 Btu/h、制热 33,200 Btu/h,4 冷吨为 36,000/45,000,两款 5 冷吨分别为 48,500/55,000 与 48,000/55,500。相对额定制热的实验室保持率,在 −15℃/−29℃ 下:3 冷吨为 107%/85%,4 冷吨为 100%/67%,一款 5 冷吨为 87%/53%,另一款为 100%/70%。Trane 未公布 COP、HSPF2 或 SEER2。产品承接美国能源部住宅寒冷气候热泵挑战:早期样机于 2022 年在橡树岭国家实验室测试,随后 9 台现场机组在明尼苏达、蒙大拿、纽约、宾夕法尼亚、威斯康星和得克萨斯累计运行超过 36,900 小时,其中制热超过 18,300 小时。Trane 称,2026年1月寒潮中,威斯康星州拉克罗斯一台 5 冷吨在低至 −29℃ 时无需辅助热源即可维持设定温度;另一台在约 −23℃ 前无需备用热源,其后启用辅助加热、热泵继续运行。配置可以是全电动空气处理机,或与暖炉组成双燃料。在额定标准与具体冷吨写入送审文件前,把「85%」固定在 3 冷吨的实验室工况上。
- Carrier 的 WeatherFlex 50FC 是对同一个 2027年1月1日 自容式货架的商用屋顶答案,容量落在欧盟页面所写的 12 kW 以上至 50 kW。机组为空气-空气,采用变频涡旋压缩机,面向新建与改造,可选自然冷却、热回收与变风量。欧盟委员会替代工质页把 R-454C 列为 GWP 146(20 年 GWP 580,安全分类 A2L),低于 GWP 150 的限制;只有现场安全要求不允许使用 GWP 低于 150 的工质时,才适用放宽到 750 的例外。Carrier 已有一档 R-454B(同一页 GWP 465)的 50FC,容量约 22–90 kW,已公布 SEER 4.49–5.07、SCOP 约 3.45–3.80。这些季节指标没有出现在新的 R-454C 系列公告里。规格书上应把工质、GWP 档位和缺失的季节性能分成三行来写。
- 还有两项适合放进初筛档案,而不是工程量清单。Cooling Post(9月21日)报道港科大弹性热装置:TiNiCuCo、双层翅片固态工质,宣称部件数量减少 50%、无效部分占比从 15% 降到 5%,并在 100 万次循环中维持 400 W 与 41 K。加速试验据称在 1 亿次后无功能衰减,团队预计实际制冷工况下可运行十年以上,同时正在开发空调。这是材料与装置结果,不是样本 COP。另一侧,Danfoss(9月22日)推出 AK-GC52 控制器,用于跨临界与亚临界 CO₂ 系统的气体冷却器与储液器压力,覆盖热泵与热回收,并配合 ICMTS 阀与 ICAD 执行器。公告没有给出系统 COP。本周无新的中国产品标准实施;JB/T 15555-2026 已经生效,GB/T 18837-2026 仍是 11月1日 的事。
影响判断
- 对英国选型:新的存量数字和第37周的改造数字描述的是不同的机器。固定单分体与多分体合计约占住宅的 0.24%;上半年下降 22% 的是 MCS 认证的空气-水改造。空气-空气正是 DESNZ 障碍清单里 BUS 未纳入的技术,而 MCS 在访谈窗口内仍在把它写进标准。第38周的秋季预算问题——税负会不会移出电费——现在旁边多了一个问题:在可逆分体被要求承担夏季舒适之前,空气-空气会不会先被承认为供热产品。
- 对工质策略:中国信号仍是冻结下的平价,开工率接近 40%。本周的低 GWP 产品新闻是 A2L,而且按市场分开。Trane 面向美国北部的住宅机组是 R-454B(GWP 465)。Carrier 的欧洲屋顶机是 R-454C(GWP 146),容量对准 2027年1月1日 起适用 GWP<150 的自容式档。弹性热结果替代不了 2027 年标书里的工质选择。
- 对项目业主:距 SB 222 期限(9月30日)还有三天,距 Chillventa(10月13–15日)约两周半,其后是 11月1日 的 GB/T 18837-2026、10月31日 的中国 2027 年配额申报,以及 2027年1月1日 同时到来的欧盟自容式 GWP<150 限制和中国 HCFC-22 多联禁产。把 Trane 的能力保持率表、Carrier 未公布的季节性能、Sauze d’Oulx 的 30℃ 升至 80℃,以及港科大的 400 W/41 K,都当作初筛输入。进入财务模型前,仍应锁定冷吨或容量档、试验标准、工质和测量边界。
- 把信号用于项目:本周的头条性能是在 −29℃ 仍保持制热能力,同时没有公布 COP 或 HSPF2。样本上的保持率仍然需要试验边界。极端测试笔记说明了为什么一个宣称温度点还不是已验证的工况。
接下来哪天
- 2026年9月24日:IOR Industry Skills Alliance 伦敦(已过;截至 9月27日未见公开决议)。9月30日:加州州长签署或否决 SB 222 的期限(三天后)。10月13–15日:Chillventa 纽伦堡(约两周半)。10月28日:英国秋季预算。10月31日:中国 2027 年 ODS/HFC 配额及初次流转申请截止。11月1日:GB/T 18837-2026《多联式空调(热泵)机组》实施。
- 2027年1月1日:欧盟对特定不超过 50 kW 的自容式空调/热泵实施 GWP<150 限制,包括 12 kW 以上一档,设安全例外;中国禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组。2027年上半年:SLB 目标完成 Kelvion 交割(第36周)。2027年4月30日 / 8月31日:2027 年征求意见稿中拟设的中国 HFC 年中配额调整窗口。
出处
- pv magazine:Trane 寒冷气候热泵至 −29℃,2026年9月25日
- pv magazine USA:Carrier WeatherFlex 50FC 屋顶热泵,2026年9月23日
- 英国 DESNZ:英国空间制冷市场图景更新,2026年9月24日
- 英国 DESNZ:图景报告 PDF
- Cooling Post:弹性热制冷装置,2026年9月21日
- Cooling Post:Sauze d’Oulx 热电联产热泵改造,2026年9月23日
- Cooling Post:Danfoss AK-GC52 CO₂ 控制器,2026年9月22日
- ChemPriceHub:华东 R32,2026年9月22–23日
- 加州议会:SB 222 法案状态
- 欧盟委员会:空调与热泵的 F-gas 替代工质
- 中国生态环境部:禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组,2026年9月2日