政策與監管
- The permit clock that weeks 36–39 left on the Governor’s desk has run out, and the official pages do not yet agree on a label. Governor Newsom’s 30 Sep legislative update lists the bills signed and vetoed that day; SB 222 is on neither list. The legislature status page, checked 4 Oct, still says “enrolled”, last action 30 Aug (“presented to the Governor”), house location “Governor”. Article IV, section 10(b)(2) of the California Constitution provides that a bill passed before 1 September and in the Governor’s possession on or after that date becomes a statute if it is not returned by 30 September. On that text, the veto window closed without a published veto. A chapter number is not on the status page, so read the enrolled bill, not a rewritten city fee sheet. The enrolled text is non-urgent and does not cover new residential construction. From 1 July 2027, cities and counties must offer asynchronous inspection of residential heat-pump water heaters and heat-pump HVAC. Permit fees are capped at $150 for a heat-pump water heater and $200 for heat-pump HVAC, with an exemption for very small jurisdictions and a written-findings route to a higher fee. Qualifying 120 V plug-in window units need no permit. Online real-time permits for defined swap-outs are due by 1 July 2028. The default start for a non-urgency statute is 1 January 2027.
- China’s compliance shelf did not move. The 31 October deadline for 2027 ODS and HFC quota and initial-transfer applications is unchanged, and the draft freeze of HFC production and use totals at 2026 levels stays provisional until a final notice. MEE announcement 2026 No. 42 still bans production of HCFC-22 multi-split air-conditioning (heat pump) units from 1 January 2027, with product scope tied to the annex and to GB/T 18837-2026, effective 1 November. JB/T 15555-2026 remains in force from 1 September. A scan of late-September and early-October national announcements did not turn up a new refrigeration or heat-pump product standard taking effect this week. In Japan, no new JIS heat-pump requirement was found taking effect this week; JIS B 8615-1:2025 (issued 21 April 2025) is the standing test method for non-ducted air conditioners and heat pumps, and an English edition circulated in September does not create a new duty. On price, the open East China tape for 28 Sep–4 Oct was not in the notes located this week. The fresh quote is a single plant: on 29 Sep, Dongyang in Ruyuan, Guangdong, held R32 at ¥66,000/t and R134a at ¥70,000/t, both unchanged on the day. That is not an East China market band. The last readable East China band remains week 39’s ¥63,500–65,500/t.
市場與產業
- The EHPA print is a residential unit count across 12 countries, and it should sit beside—not be averaged with—the UK series from weeks 37 and 39 or this week’s Norwegian installation forecast. The 12 are Austria, Belgium, Switzerland, Denmark, Finland, France, Germany, Italy, the Netherlands, Norway, Portugal and Sweden. EHPA’s own note (28 Sep) attributes the 11% rise to oil and gas prices after Iran closed the Strait of Hormuz in February, and to Commission plans encouraging governments to cut electricity tax. Director general Paul Kenny pointed to the Netherlands and Belgium as the governments that have already shifted taxes off electricity. The Commission’s Electrification Action Plan, as EHPA restates it, says tax on electricity should be no higher than tax on gas, and proposes revising network charges so flexible loads such as heat pumps are rewarded. EHPA adds that electricity taxes are still frequently higher than gas taxes. pv magazine (same day) says the 12 countries are about 80% of the European market; that share is the magazine’s framing, not a figure in the EHPA note. Set the 1.16 million units next to week 37’s MCS retrofit count for existing UK homes (20,895 in H1, −22%, about 99% air-to-water) and week 39’s fixed-split stock (about 0.24% of UK homes). One is manufacturer sales in 12 countries. One is certified fossil replacements. One is an installed base of fixed air conditioning. The UK fiscal question from week 38—whether the 28 Oct Autumn Budget moves levies off electricity—is now the British version of the sentence EHPA addressed to every EU government.
- Norway is inside the EHPA 12, and it also published a different series this week. VKE’s second-half 2026 market report (29 Sep) covers installation and maintenance of ventilation and of cooling and heat-pump plant, including controls and products, in kroner rather than residential units. That climate market fell 6.3% in 2023 and 13.1% in 2024, then levelled off in 2025 at NOK 13.6 billion. VKE forecasts +8.6% in 2026, driven largely by large hospital projects in Oslo, and a level 7.5% above 2025 by the end of 2028. Work in existing commercial buildings is 41% of the climate market and is forecast at +3.2% this year, +4.2% in 2027 and +3.4% in 2028. Data centres are named as upside, with the pace limited by access to power and grid capacity. A policy rate of 4.5%, plus higher energy prices after the Hormuz closure, is described as still holding construction below 2022. Do not add the 8.6% to the EHPA 11%.
技術與示範
- This week’s hardware news is an address and a boundary, not a seasonal rating. The Axen–Perge line (Cooling Post, 29 Sep) assembles R290 monobloc air-to-water heat pumps from 4 kW to 16 kW in single- and three-phase versions at Perge’s existing factory in Portes-lès-Valence, south of Lyon. GZ Axen Heat Pump Technology was founded in Guangzhou in 2006; Perge is a family-owned French heating firm, founded in 1971, whose catalogue has been biomass, oil and hybrid boilers. The joint venture was created at the end of April. No annual capacity, SCOP or flow temperature is in the report. A Chinese design assembled in France is still an A3 install: the missing number is the line rate, and the number a specifier still has to bring is the charge, the zone and the clearances.
- Two other footprints belong in different files. Vertiv’s 28 Sep release adds manufacturing floor for power, switchgear and thermal management, including liquid cooling for high-density AI, on an 18–24 month build. It is a data-centre cooling capacity story. It does not publish a heat-pump COP, a refrigerant or a process-temperature lift. Atlas Copco’s 2 Oct closing release gives revenue, headcount and the division—Oil-free Air, inside Compressor Technique—and describes process cooling and energy conversion. It does not repeat a product list. The chillers, industrial heat pumps, central air-handling units and dry coolers were named when the deal was first announced in July, as Cooling Post restates them this week. Treat that list as the July scope, and the RMB 1,281 million as the 2025 sales figure, until a current catalogue is attached to the acquired plants.
- The component item is a Chillventa package, and the skills item is a propane leak. Sanhua (reported 3 Oct) will show a standardised CO₂ condensing-unit kit that integrates line components, sensors, electronic expansion valves, compressor drives and controls, and leaves out the compressor and the fans. The controller, developed with Reftronix, is described for single- and dual-stage compressors, with EEV backup power, RS485, wi-fi, Ethernet, cloud access and phone monitoring. No system COP is stated. Separately, Ideal Commercial Heating (28 Sep) launched a one-hour CIBSE-approved CPD on commercial R290 air-source heat pumps: A3, DSEAR, ATEX and EN 378, hazardous-area classification, and the point that propane is denser than air and can collect in drains, pits and other low points. That is an installer constraint sitting next to the French assembly line, not a catalogue efficiency. No new Chinese product standard took effect this week.
影響判斷
- Do not average the counts. H1 residential sales rose 11% across 12 countries. UK certified retrofits in existing homes fell 22% in the same half-year. Fixed splits sit in about 0.24% of UK homes. Norway’s climate-installation market, in kroner and including ventilation, is forecast +8.6% for the full year after two down years. Each series answers a different question. The shared policy sentence is the electricity-to-gas tax. EHPA has now said it to EU governments; the UK industry said it to the Autumn Budget in week 38. A sales rebound does not by itself put air-to-air inside the Boiler Upgrade Scheme.
- Follow the factory address before the brochure. A Guangzhou design on a French boiler-maker’s floor is an R290 monobloc of 4–16 kW with no published line rate or SCOP. Slovakia’s extra 22,000 m² is liquid cooling for compute, not a dwelling heat pump. Guangdong Euroklimat’s RMB 1,281 million is a 2025 sales figure under a new owner; the industrial-heat-pump line was in the July announcement, not a tested duty in the closing release. China’s refrigerant signal is still a high, thin tape—one Guangdong plant at ¥66,000/t—under an unchanged 31 Oct filing date.
- For project owners, the clocks split. Chillventa is 13–15 Oct, nine days out, and Sanhua’s CO₂ kit is a stand item, not a commissioned plant. The UK budget is 28 Oct. China’s 2027 quota filing is 31 Oct. GB/T 18837-2026 is 1 Nov. SB 222’s own dates, if the constitutional reading holds and a chapter follows, are 1 Jan 2027 for the statute, 1 Jul 2027 for asynchronous inspection, and 1 Jul 2028 for automated swap-out permits—with the $150 / $200 caps subject to the small-jurisdiction exemption and a written override. 1 Jan 2027 is still the shared date for the EU self-contained GWP<150 limits and China’s ban on producing HCFC-22 multi-split units.
- Apply the signal: the week’s lever is a tariff comparison, not a nameplate. EHPA’s 11% is explained by gas prices and by electricity tax, which is a boundary condition. The industrial heat-pump viability note sets out why a sales print, or a factory under a new owner, still has to pass temperature lift, operating overlap and the incumbent energy price before it becomes a project.
接下來哪天
- 30 Sep 2026: California sign-or-veto window for SB 222 closed; no veto on the Governor’s list that day; chapter number not yet on the legislature status page (checked 4 Oct). 13–15 Oct: Chillventa, Nuremberg (nine days). 28 Oct: UK Autumn Budget. 31 Oct: China 2027 ODS/HFC quota and initial-transfer applications. 1 Nov: GB/T 18837-2026 for multi-split air-conditioning (heat pump) units takes effect.
- 1 Jan 2027: default start for a non-urgency California statute, which is the constitutional position of SB 222 absent a return; EU GWP<150 limits begin for defined self-contained AC/heat-pump categories up to 50 kW, subject to safety exceptions; China bans production of HCFC-22 multi-split air-conditioning (heat pump) units. 1 Jul 2027: SB 222 asynchronous-inspection duty, if chaptered as enrolled. H1 2027: SLB targets close of the Kelvion acquisition (week 36). 1 Jul 2028: SB 222 online real-time permits for defined residential swap-outs. 30 Apr / 31 Aug 2027: planned China in-year HFC quota-adjustment windows under the 2027 drafts.
出處
- EHPA — Post-Hormuz heat pump sales climb 11%, 28 Sep 2026
- pv magazine — European residential heat pump sales up 11% in H1, 28 Sep 2026
- Atlas Copco — Guangdong Euroklimat acquisition closed, 2 Oct 2026
- Cooling Post — Atlas Copco completes Chinese purchase, 2 Oct 2026
- Cooling Post — French/Chinese joint venture to produce R290 heat pumps, 29 Sep 2026
- Vertiv — Nové Mesto nad Váhom expansion, 28 Sep 2026
- Cooling Post — Vertiv Slovakian plant, 29 Sep 2026
- Cooling Post — Sales in Norway bounce back (VKE), 29 Sep 2026
- VKE — climate-market report, second half 2026, 29 Sep 2026
- Cooling Post — Sanhua CO₂ package, 3 Oct 2026
- Cooling Post — R290 heat pump CPD, 28 Sep 2026
- Office of the Governor of California — legislative update, 30 Sep 2026
- California Legislature — SB 222 bill status
- Mysteel — Dongyang refrigerant offers, Ruyuan, 29 Sep 2026
- China MEE — ban on producing HCFC-22 multi-split air-conditioning (heat pump) units, 2 Sep 2026
政策与监管
- 第36–39周放在州长案头的许可时钟已经走完,官方面页还没有统一标签。州长 Newsom 9月30日 的立法更新列出当天签署与否决的法案,SB 222 不在其中。10月4日 查看的议会状态页仍写着「已登记」,最近动作是 8月30日「呈送州长」,所在位置为「州长」。加州宪法第四条第 10 款 (b)(2) 规定:9月1日前通过、且 9月1日及之后仍在州长处的法案,若到 9月30日 仍未退回,即成为制定法。按该条文,否决窗口在没有公开否决的情况下关闭。状态页尚未出现章程号,因此应读登记文本,而不是一份已经改写的市政收费表。登记文本非紧急,且不覆盖新建住宅。自 2027年7月1日 起,市、县须为住宅热泵热水器与热泵暖通提供异步检查。许可费上限为热泵热水器 150 美元、热泵暖通 200 美元,极小辖区可豁免,并可通过书面论证收取更高费用。符合条件的 120 V 即插即用窗机无需许可。特定替换安装的在线实时许可须在 2028年7月1日 前提供。非紧急制定法的默认生效日是 2027年1月1日。
- 中国履约货架没有挪动。10月31日 提交 2027 年度 ODS 与 HFC 配额及初次流转申请的期限未变;把 HFC 产消总量冻结在 2026 年水平的草案,在正式通知印发前仍按暂定处理。生态环境部 2026 年第 42 号 公告仍规定自 2027年1月1日 起禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组,产品范围由该公告附件及将于 11月1日 实施的 GB/T 18837-2026 界定。JB/T 15555-2026 自 9月1日 起仍有效。检索 9 月下旬至 10 月上旬的国家标准公告,未见新的制冷或热泵产品标准于本周实施。日本方面,本周未见新的 JIS 热泵要求生效;JIS B 8615-1:2025(2025年4月21日 发布)仍是直吹式空调与热泵的现行试验方法,9 月流传的英译本不构成新的义务。价格方面,本周能读到的公开笔记里没有 9月28日–10月4日 的华东成交带。新报价来自单厂:广东乳源东阳光 9月29日 的 R32 报盘维持 6.6 万元/吨、R134a 维持 7 万元/吨,均与上一工作日相同。这不是华东市场区间。上一档可读的华东区间仍是第39周的 6.35–6.55 万元/吨。
市场与产业
- EHPA 这份数字是 12 国的住宅台数,应与第37、39周的英国序列以及本周的挪威安装额预测并列,而不是平均成一个需求。这 12 国是奥地利、比利时、瑞士、丹麦、芬兰、法国、德国、意大利、荷兰、挪威、葡萄牙和瑞典。EHPA 自己的说明(9/28)把 11% 的升幅归因于伊朗 2 月关闭霍尔木兹海峡之后的油气价格,以及委员会鼓励各国降低电税的计划。总干事 Paul Kenny 把荷兰和比利时点名为已经把税负移出电费的政府。按 EHPA 的转述,委员会《电气化行动计划》写明电税不应高于气税,并提议修订网络费,使热泵这类灵活负荷得到回报。EHPA 补充说,电税目前仍常常高于气税。pv magazine(同日)称这 12 国约占欧洲市场的 80%;这个份额是杂志的框定,不是 EHPA 说明里的数字。把 116 万台和第37周英国既有住宅的 MCS 改造数(上半年 20,895 台,−22%,约 99% 为空水)以及第39周的固定分体存量(约占英国住宅 0.24%)放在一起看:一个是 12 国的制造端销量,一个是认证的化石系统替换,一个是固定式空调保有量。第38周的英国财政问题——10月28日 秋季预算会不会把税负移出电费——现在就是 EHPA 对所有欧盟政府说的那句话的英国版本。
- 挪威既在 EHPA 的 12 国之内,本周又公布了另一套序列。VKE 2026 年下半年市场报告(9/29)统计的是通风以及制冷/热泵装置的安装与维护,含自控与产品,单位是克朗,不是住宅台数。该气候市场 2023 年下降 6.3%、2024 年下降 13.1%,2025 年在 136 亿挪威克朗 走平。VKE 预测 2026 年 +8.6%,主要由奥斯陆大型医院项目拉动;到 2028 年底,预计比 2025 年高 7.5%。既有商业建筑中的气候工程占气候市场的 41%,预测今年 +3.2%、2027 年 +4.2%、2028 年 +3.4%。数据中心被列为上行空间,节奏受电力与电网接入限制。政策利率 4.5%,加上霍尔木兹关闭后的能源价格,被描述为仍把建筑开工压在 2022 年之下。不要把 8.6% 和 EHPA 的 11% 相加。
技术与示范
- 本周的硬件新闻是一个地址和一条边界,不是季节性能。Axen–Perge 产线(Cooling Post,9/29)在里昂以南 Perge 既有工厂 Portes-lès-Valence 组装 R290 单体式空气-水热泵,4–16 kW,单相与三相。广州 Axen 热泵技术创立于 2006 年;Perge 是家族所有的法国供热企业,创立于 1971 年,产品目录一直是生物质、燃油与混合锅炉。合资公司于 4 月底成立。报道没有年产能、SCOP 或出水温度。中国设计在法国组装,现场仍是 A3 安装:缺的数字是产线节拍,选型仍要自己带上的是充注量、区域和间距。
- 另外两处足迹应放进不同的档案。Vertiv 9月28日 的新闻稿增加的是电力、开关柜与热管理的制造面积,包括面向高密度 AI 的液冷,建设周期 18–24 个月。这是数据中心冷却产能,没有公布热泵 COP、工质或工艺温升。阿特拉斯·科普柯 10月2日 的交割稿给出了营收、人数和部门——无油空气,位于压缩机技术业务区——并把业务写成工艺冷却与能量转换。交割稿没有重复产品清单。冷水机组、工业热泵、集中空气处理机组和干冷器,是 7 月首次宣布交易时点名的范围,Cooling Post 本周作了转述。在收购工厂附上现行样本之前,把那份清单当作 7 月的范围,把 12.81 亿元 当作 2025 年销售额。
- 部件条目是 Chillventa 上的一套包,技能条目是丙烷泄漏。三花(10/3 报道)将展示标准化 CO₂ 冷凝机组套件:集成管路元件、传感器、电子膨胀阀、压缩机驱动与控制,压缩机和风机不在套件内。与 Reftronix 合作的控制器面向单级与双级压缩机,带电子膨胀阀备用电源、RS485、Wi-Fi、以太网、云访问和手机监测。没有系统 COP。另一侧,Ideal Commercial Heating(9/28)推出一小时、经 CIBSE 认可的商用 R290 空气源热泵 CPD:A3、DSEAR、ATEX 与 EN 378、危险区域划分,以及丙烷重于空气、可在排水沟、地坑和其他低洼处积聚。这是紧挨着法国组装线的安装约束,不是样本能效。本周无新的中国产品标准实施。
影响判断
- 不要把这些计数平均。 12 国住宅销量上半年上升 11%。同一半年,英国既有住宅的认证改造下降 22%。固定分体约占英国住宅的 0.24%。挪威气候安装市场以克朗计、且包含通风,在连续两年下降之后,全年预测 +8.6%。每一套序列回答的是不同的问题。共同的政策句子是电与气的税负比较。EHPA 现已对欧盟各国政府说了这句话;英国行业在第38周对秋季预算说了同一句。销量回升本身不会把空气-空气放进锅炉升级计划。
- 先看工厂地址,再看样本。 广州设计落在法国锅炉厂的地板上,是 4–16 kW 的 R290 单体机,没有公布的产线节拍或 SCOP。斯洛伐克多出来的 2.2 万平方米 是计算负荷的液冷,不是住宅热泵。广东 Euroklimat 的 12.81 亿元 是新业主名下的 2025 年销售额;工业热泵产品线写在 7 月的宣布里,不是交割稿里的已测工况。中国的制冷剂信号仍是高位、偏薄的报价带——广东单厂 6.6 万元/吨——申报日仍是没有改动的 10月31日。
- 对项目业主,时钟已经分开。 Chillventa 是 10月13–15日,还有九天;三花的 CO₂ 套件是展台物件,不是已投运的装置。英国预算是 10月28日。中国 2027 年配额申报是 10月31日。GB/T 18837-2026 是 11月1日。若宪法读法成立且随后出现章程号,SB 222 自己的日期是:制定法 2027年1月1日,异步检查 2027年7月1日,替换安装的自动许可 2028年7月1日——150/200 美元 上限仍受极小辖区豁免和书面突破的约束。2027年1月1日 仍是欧盟自容式 GWP<150 限制与中国 HCFC-22 多联禁产的共同日期。
- 把信号用于项目:本周的杠杆是能源价格比较,不是铭牌。EHPA 的 11% 用气价和电税来解释,这是边界条件。工业热泵项目是否值得做说明了为什么一份销量,或换了业主的工厂,仍要先通过温升、同时运行时间和现有能源价格,才能变成一个项目。
接下来哪天
- 2026年9月30日:加州签署或否决 SB 222 的窗口关闭;当天州长清单无否决;议会状态页尚未出现章程号(10月4日查看)。10月13–15日:Chillventa 纽伦堡(九天后)。10月28日:英国秋季预算。10月31日:中国 2027 年 ODS/HFC 配额及初次流转申请截止。11月1日:GB/T 18837-2026《多联式空调(热泵)机组》实施。
- 2027年1月1日:非紧急加州制定法的默认生效日,即 SB 222 在未被退回时的宪法位置;欧盟对特定不超过 50 kW 的自容式空调/热泵实施 GWP<150 限制,设安全例外;中国禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组。2027年7月1日:若按登记文本成为法律,SB 222 的异步检查义务。2027年上半年:SLB 目标完成 Kelvion 交割(第36周)。2028年7月1日:SB 222 对特定住宅替换安装的在线实时许可。2027年4月30日 / 8月31日:2027 年征求意见稿中拟设的中国 HFC 年中配额调整窗口。
出处
- EHPA:霍尔木兹之后热泵销量上升 11%,2026年9月28日
- pv magazine:欧洲住宅热泵上半年销量上升 11%,2026年9月28日
- 阿特拉斯·科普柯:广东 Euroklimat 收购交割,2026年10月2日
- Cooling Post:阿特拉斯·科普柯完成对中国企业的收购,2026年10月2日
- Cooling Post:中法合资在法国生产 R290 热泵,2026年9月29日
- Vertiv:Nové Mesto nad Váhom 扩建,2026年9月28日
- Cooling Post:Vertiv 斯洛伐克工厂,2026年9月29日
- Cooling Post:挪威销售回升(VKE),2026年9月29日
- VKE:2026 年下半年气候市场报告,2026年9月29日
- Cooling Post:三花 CO₂ 套件,2026年10月3日
- Cooling Post:R290 热泵 CPD,2026年9月28日
- 加州州长办公室:立法更新,2026年9月30日
- 加州议会:SB 222 法案状态
- 我的钢铁网:乳源东阳光制冷剂报盘,2026年9月29日
- 中国生态环境部:禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组,2026年9月2日