← All cases

Cement

Public-source case — figures from published reports, papers, or vendor materials

Türkiye · Çimko Narlı cement plant: clinker cooler heat to ORC power

Clinker cooler heat drives an air-cooled organic Rankine cycle (ORC). The supplier reports operation since June 2019.

Engineering data

Case type
Public-source case — figures from published reports, papers, or vendor materials
Data status
Public-source case
Data source
Turboden, equipment supplier’s Çimko case: https://www.turboden.com/references/case-histories/620/cimko
Reviewer / date
Editorial (Open Thermal AI) · 2026-11-24
Industry
Cement
Energy source
Excess heat from the clinker cooler.
Energy use
On-site electricity generation via an air-cooled ORC unit.
Architecture
A heat-recovery boiler and thermal-oil loop transfer cooler heat to the ORC.
Result status
The supplier gives 6.4 MWe as the unit’s design peak electrical output.
Key risk
The 6.4 MWe figure is a design peak. The disclosure gives no annual net generation. Cooler heat availability and ambient temperature affect output.

Project background

The Narlı plant in Kahramanmaraş recovers heat from clinker cooling. The ORC supplier identifies the project as a cement plant application in operation since June 2019.

Narrative inputs

Record clinker line output, cooler exhaust temperature and flow, usable hours, ambient temperature and other users of the same heat.

Recovery system

The thermal-oil loop delivers recovered heat to the ORC evaporator. An air-cooled condenser rejects heat after expansion.

Performance boundary

Evaluate electricity supplied to the plant after pumps, condenser fans and other auxiliaries. Compare with production and ambient records from the same period.

Investment / ROI notes

The supplier case gives no project payback. Compare the value of net electricity and direct heat use against installed cost, downtime and maintenance.