United States · Mary Ann Gas Plant: steam pressure recovery and control
A U.S. Department of Energy case study shows how an existing backpressure generator was operated to follow downstream steam demand.
Engineering data
- Case type
- Public-source case — figures from published reports, papers, or vendor materials
- Data status
- Public-source case
- Data source
- U.S. Department of Energy, 2002 project case: https://www1.eere.energy.gov/manufacturing/tech_assistance/pdfs/chem_cs_exxonmobil.pdf
- Reviewer / date
- Editorial (Open Thermal AI) · 2026-11-24
- Industry
- Oil & gas
- Energy source
- 450 psig high-pressure steam from fired boilers and waste heat steam generators.
- Energy use
- Power generation with exhaust steam supplied to the 60 psig intermediate header.
- Architecture
- Existing backpressure steam turbine and revised steam-header controls.
- Result status
- The DOE case attributes 170 billion Btu per year of energy savings to the 1998 steam-system control revisions.
- Key risk
- The reported savings apply to steam-system controls. Standalone generation gains are undisclosed. Preserve downstream steam demand and account for fired-boiler fuel.
Project background
The Mobile, Alabama plant originally ran fired boilers to keep the existing generator heavily loaded. Changes in the supply of waste-heat steam prompted a system review.
Narrative inputs
Log demand and pressure at each header, turbine and bypass valve flows, boiler fuel use and steam sent to the condenser.
Recovery system
The revised controls shifted primary high-pressure control to the boilers and ran the turbine to follow medium-pressure demand, reducing steam letdown through valves and unnecessary condensation.
Performance boundary
The DOE publication reports whole-system results. Compare fuel and net electricity for the same downstream steam delivery when evaluating an expander.
Investment / ROI notes
The DOE reports about US$375,000 in annual savings from the control changes. This historical cost result depends on the site’s steam balance and its energy costs.