India · Tata Steel Kalinganagar: coke dry quenching for power

Tata Steel documents an installed coke dry quenching (CDQ) system that recovers heat from hot coke to make steam for power generation.

Engineering data

Case type
Public-source case — figures from published reports, papers, or vendor materials
Data status
Public-source case
Reviewer / date
Editorial (Open Thermal AI) · 2026-11-24
Industry
Steel
Energy source
Hot coke from coke ovens, at about 1,000°C in Tata Steel’s description.
Energy use
Steam from the waste heat boiler supplies power generation.
Architecture
Inert gas cools the hot coke and carries the heat to a waste heat boiler.
Result status
Tata Steel reported an installed CDQ system rated to handle 200 tonnes of coke per hour in 2017.
Key risk
The 200 t/h figure rates coke throughput. Annual net generation is undisclosed in the cited release. Assess quenching continuity, dust, gas tightness and auxiliary loads.

Project background

The owner installed CDQ at its Kalinganagar steelworks in Odisha as an alternative to conventional wet quenching.

Narrative inputs

Record coke throughput and inlet temperature by operating period, steam output and pressure, and the electricity required by fans and handling equipment.

Recovery system

An inert-gas circuit takes heat from red-hot coke. A waste heat boiler turns the recovered heat into steam for electricity generation.

Performance boundary

Evaluate steam output and net electricity on the same operating boundary. Check water use and coke quality against the wet-quenching baseline separately.

Investment / ROI notes

Payback is undisclosed. Compare capital and maintenance costs with net power and water savings, accounting for downtime and alternative quenching arrangements.