Policy & Regulation
- The Dutch letter is a direction and a timetable, not a statute. On 7 Oct, housing minister Elanor Boekholt-O’Sullivan wrote to the House of Representatives, also on behalf of the climate minister, that from 2029 a smart hybrid heat pump becomes the starting point when a gas boiler is replaced, in many homes, and that fitting only a new boiler will no longer do. The rule is to be written into the Living Environment Buildings Decree by tightening the existing efficiency requirement for heating installations. That requirement is technology-neutral and is to be set so that a hybrid heat pump meets it. A fully electric heat pump meets it too. A boiler alone, infrared panels or an electric heater do not. It would apply at replacement—usually a move, a renovation or the end of the boiler’s life—not as a forced early scrap. Three cases are already marked as undesirable or not feasible in 2029: homes due to be connected to a heat network in the short term; apartment buildings, where space, noise and a small heat load can make a heat pump a poor fit; and monuments, where a heat pump needs a heritage permit and a refusal would make compliance impossible. The precise boundary is still being drawn, and whether schools and commercial buildings are inside the norm is still an open cabinet choice. An external study of payback within the equipment’s life is due in early 2027. After the spring 2027 decision on further climate measures, the minister will write again; consultation and parliamentary preview are planned for the summer and autumn of 2027; publication of the decree changes is planned for mid-2028, so that 2029 is the earliest entry the letter itself calls feasible. The 65% less gas for heating and the more-than-30% cut in the home’s CO₂ are Milieu Centraal’s description of a hybrid heat pump already in use. The letter’s own footnote says the saving depends on gas use, dwelling type, insulation and energy prices. They are not an evaluated effect of a rule that is not yet written. “Smart” means controllable: able to heat outside grid peaks or when the power price is low. The letter points to a Dutch Technical Agreement drawn up with the sector and does not print its number. NEN’s record for NTA 8171:2026 gives 1 Oct as the publication date and 6 Oct as the registration date; NEN’s news item is dated 7 Oct. That agreement applies to heat-pump installations on the low-voltage network with a maximum thermal capacity of 70 kW, for space heating, domestic hot water and/or space cooling. The 2029 norm is not thereby limited to 70 kW; the letter has not yet said how the agreement will be used above that line.
- China’s compliance shelf did not move. The 31 October deadline for 2027 ODS and HFC quota and initial-transfer applications is unchanged, and the draft freeze of HFC production and use totals at 2026 levels stays provisional until a final notice. MEE announcement 2026 No. 42 still bans production of HCFC-22 multi-split air-conditioning (heat pump) units from 1 January 2027, with product scope tied to the annex and to GB/T 18837-2026, effective 1 November. JB/T 15555-2026 remains in force from 1 September. A scan of the national standards platform on 11 Oct did not turn up a new refrigeration or heat-pump product standard taking effect between 5 and 11 October. GB/T 18837-2026 is still marked as not yet in force, with 1 November as its effective date. In Japan, no new JIS heat-pump requirement was found taking effect this week; JIS B 8615-1:2025 (issued 21 April 2025) remains the standing test method for non-ducted air conditioners and heat pumps, and the JSA record still lists it as current. On the California page, checked 11 Oct, SB 222 is still labelled enrolled, last action 30 Aug (“presented to the Governor”), house location “Governor”, and no chapter number is posted. The enrolled dates from week 40 therefore stay conditional on a chapter. On price, three tapes do not make one band. 隆众’s East China note of 9 Oct, carried on Mysteel, gives a mainstream R32 band of ¥63,500–64,500/t, tighter at the top than week 39’s ¥63,500–65,500/t. Juhua in Zhejiang, on 10 Oct, held R32 at ¥65,500/t, unchanged on the day. Dongyang in Ruyuan, Guangdong, on 8 Oct, held R32 at ¥66,000/t and R134a at ¥70,000/t, both unchanged on the day. The two plant quotes are not the East China band.
Market & Industry
- AHRI’s August print is a U.S. factory shipment, and it should sit beside—not be added to—Canada’s rebate ceiling, week 40’s EHPA count, or the UK series from week 37. The release, published 9 Oct, counts 756,739 central air conditioners and air-source heat pumps in August 2026, 11.4% above 679,378 in August 2025. Inside that total, air conditioners are 418,323 (+17.2%, from 356,930) and air-source heat pumps are 338,416 (+5.0%, from 322,448). Year to date, the combined total is 6,390,257 (+6.2%), air conditioners 3,481,613 (+6.5%), and heat pumps 2,908,644 (+5.7%, from 2,751,248). The combined 11.4% is pulled by air conditioners. Set the 338,416 heat pumps next to Canada’s still-unopened ceiling of 820,000 households, EHPA’s 1.16 million residential units across 12 countries in the first half, and week 37’s MCS retrofit count for existing UK homes (20,895 in H1, −22%). One is August shipments. One is a rebate that has no opening date. One is manufacturer sales in 12 countries. One is certified fossil replacements. Do not add them.
- Three other announcements belong in different files. Beijer Ref (9 Oct) completed the purchase of 90% of Refra, the Lithuanian maker of natural-refrigerant HVAC/R systems, with an option on the rest, after unconditional approval from the Lithuanian competition authority. Refra stays under its own brand and enters the group accounts on 9 Oct. The closing release does not repeat a turnover. The 24 Aug agreement put annual turnover at about SEK 500 million, with what Beijer called good profitability. Treat the SEK 500 million as the August figure, not a tested duty in the closing note. LG Electronics USA (5 Oct) signed a long-term agreement with AIR Control Concepts to supply chillers for AI data-centre projects in the United States and Canada exceeding 5 GW of capacity. The company release does not state a contract price, a refrigerant or a heat-pump COP. It is a data-centre cooling capacity story, in the same file as week 40’s Slovakian floor area, not a dwelling heat pump. On 9 Oct the Governor of New York said Solstice Advanced Materials will spend $49 million to renovate its Peabody Street research site in Buffalo, adding 12 jobs to a workforce of about 180. Refrigeration is one of several industries named. That is a laboratory address, not a new refrigerant price.
Technology & Demonstrations
- Two R290 machines arrived this week with different evidence, and the numbers do not travel between them. Carrier’s AquaSnap 61WH product page describes a water-source heat pump, GWP 0.02 on an AR6 basis, producing hot water up to 78°C, and lists boiler replacement among the uses. Cooling Post (8 Oct) and Natural Refrigerants (9 Oct) put the modular heating capacity at 50–824 kW. That kilowatt span is theirs, not a figure on the product page consulted here. No charge, SCOP or source-side temperature is stated. Do not borrow the February 2025 air-source 61AQ (40–140 kW, modular to about 560 kW, up to 75°C). Separately, Natural Refrigerants (9 Oct) reports Johnson Controls’ YORK YMAE-P as a reversible air-to-water R290 unit of 90–360 kW, producing hot water up to 80°C at an ambient temperature as low as −25°C, to be shown first at Chillventa. The company flyer linked from its 1 Oct post did not open here, so no GWP is taken from that post, and the 80°C / −25°C pair is the trade report’s, not a tested project lift. Week 36’s Sabroe line is not this machine.
- Natural Refrigerants (9 Oct) also reports that INTEGASA is building a 7 MW ammonia spray chiller, the first of six, for two wastewater heat pumps of 25 MW and 20 MW on a Danish district-heating network. The manufacturer’s own spray-chiller pages describe other jobs, including a Swiss heat-pump cooler, and do not carry this Danish rating. Treat the 7 MW, the six units and the two heat-pump sizes as the trade report’s figures. No ammonia charge in kilograms is stated. “Exceptionally low” is the company’s phrase, as relayed, not a measured inventory.
- The installer item is a pipe, not a seasonal rating. Heat Pump Association UK’s external pipework insulation guide is dated 5 Oct (version 1.0). Its own scope is a monobloc air-to-water heat pump outdoors within the curtilage of a house. The document says it does not cover flats, multi-occupancy buildings, high-rise dwellings or commercial buildings. Cooling Post (7 Oct) reports that MCS has endorsed it and that external pipework insulation is the leading non-conformity on MCS audits; that ranking is the report’s, and it is not a sentence in the guide’s opening pages. It sits next to week 40’s French R290 assembly line: the missing number there was the line rate; the missing practice here is continuous, sealed insulation on the outdoor run. Secon, reported on 8 Oct, will show an indoor water-cooled R290 module at Chillventa with flow temperatures up to 75°C. That is a stand item, not a commissioned plant. No new Chinese product standard took effect this week.
Why It Matters
- Do not add the counts. A Dutch letter sets 2029 as the earliest date for a hybrid standard that is not yet in the decree. Canada’s rebate ceiling is 820,000 households, and the portal has no published opening date. EHPA’s first-half residential sales were 1.16 million units across 12 countries. UK certified retrofits in existing homes were 20,895 in that half-year, down 22%. AHRI’s August air-source heat pumps rose 5.0%, to 338,416; the 11.4% belongs to the combined air-conditioner and heat-pump total, which air conditioners pulled. Each series answers a different question. A letter is not a mandate, a rebate that is not open is not a sales print, and a combined shipment rate is not a heat-pump rate.
- Follow the address before the brochure. Refra’s SEK 500 million is an August turnover under a close dated 9 Oct; the closing note does not restate a tested duty. The extra 5 GW is chiller capacity for compute projects, and the contract price is not in LG’s release. Buffalo’s $49 million is a research building, not a molecule. The 78°C on the 61WH page is a catalogue water temperature; the 50–824 kW span is trade press. The YMAE-P’s 80°C at −25°C is a trade report of a Chillventa debut, and the linked flyer did not open. China’s refrigerant signal is three tapes—East China ¥63,500–64,500/t on 9 Oct, Juhua at ¥65,500/t on 10 Oct, Dongyang at ¥66,000/t on 8 Oct—under an unchanged 31 Oct filing date.
- For project owners, the clocks split. Chillventa’s congress is 12 Oct, tomorrow, and the fair is 13–15 Oct. The UK budget is 28 Oct. China’s 2027 quota filing is 31 Oct. GB/T 18837-2026 is 1 Nov. The Dutch decree is planned for mid-2028, for a 2029 start, after a spring 2027 decision and a summer–autumn 2027 consultation. Canada’s portal has no date in the Prime Minister’s release. SB 222’s own dates stay those of the enrolled text—1 Jan 2027, 1 Jul 2027, 1 Jul 2028—until a chapter number is on the legislature page. 1 Jan 2027 is still the shared date for the EU self-contained GWP<150 limits and China’s ban on producing HCFC-22 multi-split units.
- Apply the signal: the week’s lever is a replacement rule and a breakdown rebate, not a nameplate, and a shipment print is not a project lift. The Dutch exceptions—heat-network homes, apartments, monuments—and the Canadian opening date that has not been printed are boundary conditions. The industrial heat-pump viability note sets out why a future boiler rule, a rebate that pays when the furnace fails, or an August shipment count, still has to pass temperature lift, operating overlap and the incumbent energy price before it becomes a project.
Coming up
- 12 Oct 2026: Chillventa congress, Nuremberg, including the refrigerant-transition panel (tomorrow). 13–15 Oct: Chillventa. 28 Oct: UK Autumn Budget. 31 Oct: China 2027 ODS/HFC quota and initial-transfer applications. 1 Nov: GB/T 18837-2026 for multi-split air-conditioning (heat pump) units takes effect.
- 1 Jan 2027: EU GWP<150 limits begin for defined self-contained AC/heat-pump categories up to 50 kW, subject to safety exceptions; China bans production of HCFC-22 multi-split air-conditioning (heat pump) units; default start for a non-urgency California statute if SB 222 is chaptered as enrolled. Early 2027: Dutch external study of hybrid-heat-pump payback due. Spring 2027: Dutch decision on further climate measures, then a further letter on the hybrid norm. Summer and autumn 2027: Dutch consultation and parliamentary preview of the decree. 1 Jul 2027: SB 222 asynchronous-inspection duty, if chaptered as enrolled. H1 2027: SLB targets close of the Kelvion acquisition (week 36). Mid-2028: planned publication of the Dutch Buildings Decree changes. 1 Jul 2028: SB 222 online real-time permits for defined residential swap-outs. 2029: earliest date the Dutch letter gives for the hybrid norm to enter into force. 30 Apr / 31 Aug 2027: planned China in-year HFC quota-adjustment windows under the 2027 drafts.
Sources
- Government of the Netherlands — smart and hybrid heat pumps the new standard from 2029, 7 Oct 2026
- Letter to parliament — proposed norm for smart hybrid heat pumps, 7 Oct 2026
- NEN — NTA 8171:2026 Smart heat pumps
- NEN — NTA 8171 published, 7 Oct 2026
- Prime Minister of Canada — one million home retrofits, 8 Oct 2026
- AHRI — August 2026 U.S. heating and cooling shipments, published 9 Oct 2026
- AHRI — August 2026 statistical release (PDF)
- Beijer Ref — acquisition of Refra closed, 9 Oct 2026
- Beijer Ref — agreement to acquire Refra, 24 Aug 2026
- LG Electronics — chiller supply agreement with AIR Control Concepts, 5 Oct 2026
- Governor of New York — Solstice Buffalo R&D expansion, 9 Oct 2026
- Natural Refrigerants — YORK YMAE-P, 9 Oct 2026
- Natural Refrigerants — INTEGASA ammonia spray chiller, 9 Oct 2026
- Carrier — AquaSnap 61WH product page
- Cooling Post — Carrier R290 water-source heat pump, 8 Oct 2026
- Natural Refrigerants — Carrier 61WH, 9 Oct 2026
- Heat Pump Association UK — external pipework insulation guidance, version 1.0, 5 Oct 2026
- Cooling Post — heat-pump pipework insulation guide, 7 Oct 2026
- Natural Refrigerants — Secon R290 module for Chillventa, 8 Oct 2026
- Mysteel / 隆众 — East China refrigerant prices, 9 Oct 2026
- Mysteel / 隆众 — Juhua refrigerant offers, Zhejiang, 10 Oct 2026
- Mysteel / 隆众 — Dongyang refrigerant offers, Ruyuan, 8 Oct 2026
- California Legislature — SB 222 bill status
- China MEE — ban on producing HCFC-22 multi-split air-conditioning (heat pump) units, 2 Sep 2026
政策与监管
- 荷兰这封信是方向和时间表,不是制定法。10月7日,住房部长 Elanor Boekholt-O’Sullivan 致函议会,并代表气候部长:自 2029 年起,在许多住宅里,更换燃气锅炉时智能混合式热泵成为出发点,只装一台新锅炉将不再符合要求。规则将写入《建筑环境法令》,办法是收紧现有的供热装置效率要求。该要求技术中立,并拟设成混合式热泵能够满足。全电动热泵也满足。单独的锅炉、红外板或电暖器不满足。它在更换时适用——通常是搬家、改造或锅炉寿命终结——而不是强制提前报废。三类情形已被标明为不宜或到 2029 年不可行:短期内将接入热网的住宅;公寓楼,空间、噪声和较小的热负荷可能使热泵并不合适;文物建筑,热泵需要文物许可,许可被拒就无法履行义务。精确边界仍在划定,学校和商业建筑是否纳入仍是内阁未决的选择。关于能否在设备寿命内收回投资的外部研究,预计 2027 年初完成。2027 年春就进一步气候措施作出决定后,部长将再次致函;咨询和议会预先审查安排在 2027 年夏秋;法令修订的公布安排在 2028 年中,因此 2029 年是信件自己称为最早可行的生效时点。采暖少用 65% 燃气、住宅 CO₂ 下降逾 30%,是 Milieu Centraal 对已经在用的混合式热泵的描述。信件自己的脚注写明,节省取决于用气量、住宅类型、保温和能源价格。它们不是一条尚未写成的规则的评估结果。「智能」指可调节:能在电网高峰之外或电价低时供热。信件指向一份与行业共同起草的荷兰技术协议,但没有印出编号。NEN 对 NTA 8171:2026 的记录把发布日写成 10月1日、注册日写成 10月6日;NEN 的新闻日期是 10月7日。该协议适用于接入低压电网、最大热容量 70 kW 的热泵装置,覆盖空间供热、生活热水和/或空间供冷。2029 年的规范并不因此被限制在 70 kW;信件还没有说明这条协议在该线以上如何使用。
- 中国履约货架没有挪动。10月31日 提交 2027 年度 ODS 与 HFC 配额及初次流转申请的期限未变;把 HFC 产消总量冻结在 2026 年水平的草案,在正式通知印发前仍按暂定处理。生态环境部 2026 年第 42 号 公告仍规定自 2027年1月1日 起禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组,产品范围由该公告附件及将于 11月1日 实施的 GB/T 18837-2026 界定。JB/T 15555-2026 自 9月1日 起仍有效。10月11日 检索国家标准平台,未见新的制冷或热泵产品标准于 10月5–11日 实施。GB/T 18837-2026 仍标为即将实施,生效日仍是 11月1日。日本方面,本周未见新的 JIS 热泵要求生效;JIS B 8615-1:2025(2025年4月21日 发布)仍是直吹式空调与热泵的现行试验方法,日本规格协会记录仍列为有效。加州页面于 10月11日 查看时,SB 222 仍标为已登记,最近动作是 8月30日「呈送州长」,所在位置为「州长」,章程号没有挂出。第40周登记文本上的日期因此仍以章程号为条件。价格方面,三条带子不是一个区间。隆众 10月9日、经我的钢铁网刊出的华东笔记,把 R32 主流区间写为 6.35–6.45 万元/吨,上沿比第39周的 6.35–6.55 万元/吨 更紧。浙江巨化 10月10日 的 R32 维持 6.55 万元/吨,与上一工作日相同。广东乳源东阳光 10月8日 的 R32 维持 6.6 万元/吨、R134a 维持 7 万元/吨,均与上一工作日相同。两家工厂的报盘不是华东区间。
市场与产业
- AHRI 的 8 月数字是美国工厂出货,应与加拿大的补贴上限、第40周的 EHPA 计数以及第37周的英国序列并列,而不是相加。这份于 10月9日 公布的统计,把 2026 年 8 月的中央空调与空气源热泵写成 756,739 台,比 2025 年 8 月的 679,378 台高 11.4%。其中空调 418,323 台(+17.2%,上年 8 月 356,930 台),空气源热泵 338,416 台(+5.0%,上年 8 月 322,448 台)。年初至 8 月,合计 6,390,257 台(+6.2%),空调 3,481,613 台(+6.5%),热泵 2,908,644 台(+5.7%,上年同期 2,751,248 台)。合计的 11.4% 是空调拉上去的。把 338,416 台热泵和加拿大尚未开门的 82 万户上限、EHPA 12 国上半年住宅 116 万台,以及第37周英国既有住宅的 MCS 改造数(上半年 20,895 台,−22%)放在一起:一个是 8 月出货,一个是没有开放日的补贴,一个是 12 国的制造端销量,一个是认证的化石系统替换。不要把它们相加。
- 另外三则宣布应放进不同的档案。Beijer Ref(10月9日)在立陶宛竞争主管机关无条件批准后,完成收购自然工质暖通制冷设备制造商 Refra 90% 的股权,余下股份留有选择权。Refra 继续使用自己的品牌,并自 10月9日 起纳入集团报表。交割稿没有重复营业额。8月24日 的协议把年营业额写为约 5 亿瑞典克朗,Beijer 称之为盈利良好。把 5 亿瑞典克朗 当作 8 月的数字,而不是交割稿里的已测工况。LG Electronics USA(10月5日)与 AIR Control Concepts 签订长期协议,为美国和加拿大 AI 数据中心项目供应冷水机组,项目容量超过 5 GW。公司稿没有合同金额、工质或热泵 COP。这是数据中心冷却产能,与第40周斯洛伐克的厂房面积放在同一份档案里,不是住宅热泵。10月9日,纽约州州长称 Solstice Advanced Materials 将投入 4,900 万美元改造布法罗 Peabody 街的研究设施,在约 180 人的队伍上增加 12 个岗位。制冷是被点名的若干行业之一。这是实验室地址,不是新的工质价格。
技术与示范
- 本周两台 R290 带着不同的证据到来,数字不能从一台搬到另一台。开利 AquaSnap 61WH 的产品页把机器写成水源热泵,按 AR6 的 GWP 为 0.02,热水至 78°C,用途里包括替换锅炉。Cooling Post(10月8日)和 Natural Refrigerants(10月9日)把模块化制热能力写成 50–824 kW。这个千瓦跨度是它们的,不是此处查阅的产品页上的数字。充注量、SCOP 和源侧温度都没有写。不要借用 2025 年 2 月那台空气源 61AQ(40–140 kW,模块化至约 560 kW,至 75°C)。另一侧,Natural Refrigerants(10月9日)把江森自控的约克 YMAE-P 写成可逆空气-水 R290,90–360 kW,环境温度低至 −25°C 时出水至 80°C,将在 Chillventa 首展。公司 10月1日 帖子链出的传单此处没有打开,因此不从那篇帖子取 GWP;80°C / −25°C 这一对是报道里的数字,不是已测的项目温升。第36周的 Sabroe 产品线不是这台机器。
- Natural Refrigerants(10月9日)还报道,INTEGASA 正在制造一台 7 MW 氨喷淋冷却器,是六台中的第一台,用于丹麦区域供热网上两台分别 25 MW 和 20 MW 的污水热泵。制造商自己的喷淋冷却器页面写的是其他项目,包括一台瑞士热泵冷却器,没有这组丹麦额定值。把 7 MW、六台和两台热泵容量当作报道里的数字。没有以千克计的氨充注量。「极低」是公司的说法,经转述,不是一份测得的存量。
- 安装条目是一根管子,不是季节性能。英国热泵协会的室外管道保温指南日期为 10月5日(1.0 版)。它自己的范围是住宅用地范围内、安装在室外的单体式空气-水热泵。文件写明不覆盖公寓、多户建筑、高层住宅或商业建筑。Cooling Post(10月7日)报道 MCS 已认可该指南,且室外管道保温是 MCS 审核中最常见的不符合项;这个排序是报道的,不是指南开篇里的句子。它紧挨着第40周的法国 R290 组装线:那边缺的数字是产线节拍,这边缺的做法是室外管段连续、密封的保温。10月8日 报道的 Secon 将在 Chillventa 展示室内水冷 R290 模块,出水温度至 75°C。这是展台物件,不是已投运的装置。本周无新的中国产品标准实施。
影响判断
- 不要把这些计数相加。 荷兰的信件把 2029 年写成一条尚未进入法令的混合式标准的最早日期。加拿大的补贴上限是 82 万户,门户开放日尚未公布。EHPA 的上半年住宅销量是 12 国 116 万台。英国既有住宅的认证改造在同一个半年是 20,895 台,下降 22%。AHRI 8 月的空气源热泵上升 5.0%,至 338,416 台;11.4% 属于空调与热泵的合计,而且是空调拉上去的。每一套序列回答的是不同的问题。一封信不是义务,一份还没开门的补贴不是销量,一个合计增速也不是热泵增速。
- 先看地址,再看样本。 Refra 的 5 亿瑞典克朗 是 8 月的营业额,挂在 10月9日 的交割之下;交割稿没有重述已测工况。多出来的 5 GW 是计算项目的冷水机组容量,合同价格不在 LG 的稿子里。布法罗的 4,900 万美元 是一栋研究楼,不是一种分子。61WH 页面上的 78°C 是样本水温;50–824 kW 的跨度来自行业媒体。YMAE-P 在 −25°C 时的 80°C 是一篇展前报道,所链传单没有打开。中国的制冷剂信号是三条带子——10月9日 华东 6.35–6.45 万元/吨、10月10日 巨化 6.55 万元/吨、10月8日 东阳光 6.6 万元/吨——申报日仍是没有改动的 10月31日。
- 对项目业主,时钟已经分开。 Chillventa 大会是 10月12日,即次日;展会是 10月13–15日。英国预算是 10月28日。中国 2027 年配额申报是 10月31日。GB/T 18837-2026 是 11月1日。荷兰法令修订计划在 2028 年中公布,以便 2029 年生效,在此之前还有 2027 年春的决定和 2027 年夏秋的咨询。加拿大门户在总理新闻稿里没有日期。SB 222 自己的日期仍是登记文本上的日期——2027年1月1日、2027年7月1日、2028年7月1日——直到议会页面出现章程号。2027年1月1日 仍是欧盟自容式 GWP<150 限制与中国 HCFC-22 多联禁产的共同日期。
- 把信号用于项目:本周的杠杆是更换规则和故障补贴,不是铭牌;一份出货统计也不是项目温升。荷兰的例外——热网住宅、公寓、文物建筑——以及加拿大还没有印出来的开放日,都是边界条件。工业热泵项目是否值得做说明了为什么一条未来的锅炉规则、一份在炉子坏掉时才支付的补贴,或一个月的出货数,仍要先通过温升、同时运行时间和现有能源价格,才能变成一个项目。
接下来哪天
- 2026年10月12日:Chillventa 纽伦堡大会,包括制冷剂转型讨论(次日)。10月13–15日:Chillventa 展会。10月28日:英国秋季预算。10月31日:中国 2027 年 ODS/HFC 配额及初次流转申请截止。11月1日:GB/T 18837-2026《多联式空调(热泵)机组》实施。
- 2027年1月1日:欧盟对特定不超过 50 kW 的自容式空调/热泵实施 GWP<150 限制,设安全例外;中国禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组;若 SB 222 按登记文本成为法律,非紧急加州制定法的默认生效日。2027年初:荷兰混合式热泵投资回收的外部研究到期。2027年春:荷兰就进一步气候措施作决定,并再次致函说明混合式规范。2027年夏秋:荷兰法令的咨询与议会预先审查。2027年7月1日:若按登记文本成为法律,SB 222 的异步检查义务。2027年上半年:SLB 目标完成 Kelvion 交割(第36周)。2028年中:荷兰《建筑环境法令》修订的计划公布时间。2028年7月1日:SB 222 对特定住宅替换安装的在线实时许可。2029年:荷兰信件给出的混合式规范最早生效年。2027年4月30日 / 8月31日:2027 年征求意见稿中拟设的中国 HFC 年中配额调整窗口。
出处
- 荷兰政府:智能与混合式热泵自 2029 年起成为新标准,2026年10月7日
- 致议会信:拟议的智能混合式热泵规范,2026年10月7日
- NEN:NTA 8171:2026 智能热泵
- NEN:NTA 8171 公布,2026年10月7日
- 加拿大总理:100 万户住宅改造,2026年10月8日
- AHRI:2026年8月美国供热与供冷设备出货,2026年10月9日公布
- AHRI:2026年8月统计稿(PDF)
- Beijer Ref:完成收购 Refra,2026年10月9日
- Beijer Ref:协议收购 Refra,2026年8月24日
- LG 电子:与 AIR Control Concepts 的冷水机组供货协议,2026年10月5日
- 纽约州州长:Solstice 布法罗研发扩建,2026年10月9日
- Natural Refrigerants:约克 YMAE-P,2026年10月9日
- Natural Refrigerants:INTEGASA 氨喷淋冷却器,2026年10月9日
- 开利:AquaSnap 61WH 产品页
- Cooling Post:开利 R290 水源热泵,2026年10月8日
- Natural Refrigerants:开利 61WH,2026年10月9日
- 英国热泵协会:室外管道保温指南 1.0 版,2026年10月5日
- Cooling Post:热泵管道保温指南,2026年10月7日
- Natural Refrigerants:Secon 将在 Chillventa 展示的 R290 模块,2026年10月8日
- 我的钢铁网 / 隆众:华东制冷剂价格,2026年10月9日
- 我的钢铁网 / 隆众:浙江巨化制冷剂报盘,2026年10月10日
- 我的钢铁网 / 隆众:乳源东阳光制冷剂报盘,2026年10月8日
- 加州议会:SB 222 法案状态
- 中国生态环境部:禁止生产以 HCFC-22 为制冷剂的多联式空调(热泵)机组,2026年9月2日