Understand the basics. Prepare for your site.

Explore how heat pumps work, choose a site checklist, or check this project. Start with the part you need.

Start with where the heat goes

A heat pump uses drive energy to move heat from a source to a useful temperature. Explore three ways to drive it, then check the conditions at your own site.

New to industrial heat pumps? Learn which heating tasks they may serve →

3-minute video & download

Open a checklist →

Follow the energy through a heat pump

One heat source, different ways to drive a heat pump.

Choose a drive

Electric motor drive

ElectricityMotor → compressor
Heat sourceRecoverable heat
Compression
Heat sinkUseful process heat

Source heat + electrical input ≈ heat delivered

Check temperatures, simultaneous demand and auxiliary electricity before assessing savings.

Type I absorption example

High-temperature heatThermal drive
Heat sourceRecoverable heat
Absorption
Heat sinkMedium-temperature heat

Low-temperature heat + driving heat ≈ heat delivered

Driving heat is hotter than the heat delivered. Pumps still use electricity; this diagram does not cover every heat-driven cycle.

Compression with a steam-turbine drive

Steam turbineShaft work
Steam supplyPressure & flow
Exhaust steamUse or condense
Heat sourceRecoverable heat
Compression
Heat sinkUseful process heat

Source heat + shaft work ≈ heat-pump output

Steam first produces shaft work. Account separately for steam supply, exhaust use and auxiliaries when comparing the whole system.

The screening tool does not model heat-driven or steam-turbine-driven systems.

How to read this diagram & its source

These are representative routes, not a complete classification. A Type II absorption heat transformer instead splits medium-temperature heat into a smaller high-temperature output and a low-temperature rejected stream. Its energy diagram and COP boundary differ.

Original illustration informed by Annex 58 Task 1, Fig. 1-1, §1.2.2 and §2.2.1.8. Not an official IEA graphic or endorsement.

Read the Task 1 report → Explore heat-pump principles →

Which equipment or process are you reviewing?

Choose a device or process to get a checklist and follow-up tasks. Record what you know, leave unknowns blank, and fill online or print a copy.

Not sure which to choose? Start with three optional questions →

Identify a heat pump or shortlist a technology with field checks →

A checklist prepares your data; it does not calculate savings or establish feasibility.

These are common ways in, not every application. Space heating, simultaneous heating and cooling, and other sources such as flue gas or seawater continue on the opportunity atlas.

Not sure where to start? Three optional questions

All answers may be unknown. This guide recommends reading and data to collect; it does not calculate savings.

Explore only what you need

What will the first screen tell me?

See COP, energy use, annual cost change, and payback when investment is known.

Get missing-data items, engineering risks, and what to verify on site or with an OEM.

What data do I need?

Four inputs are enough to begin

  1. 1Source temperature
  2. 2Target temperature
  3. 3Heat duty or energy bill
  4. 4Run hours and energy price

You can start with incomplete data. The evaluation will show what is still missing instead of inventing values.

Not ready with the data? Ask the engineering assistant →
I want to understand the options first
Already working on a project?